Cargando…
Knowledge-based planning for multi-isocenter VMAT total marrow irradiation
PURPOSE: Total marrow irradiation (TMI) involves optimization of extremely large target volumes and requires extensive clinical experience and time for both treatment planning and delivery. Although volumetric modulated arc therapy (VMAT) achieves substantial reduction in treatment delivery time, pl...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9577613/ https://www.ncbi.nlm.nih.gov/pubmed/36267964 http://dx.doi.org/10.3389/fonc.2022.942685 |
_version_ | 1784811794277072896 |
---|---|
author | Ahn, Kang-Hyun Rondelli, Damiano Koshy, Matthew Partouche, Julien A. Hasan, Yasmin Liu, Hongtao Yenice, Kamil Aydogan, Bulent |
author_facet | Ahn, Kang-Hyun Rondelli, Damiano Koshy, Matthew Partouche, Julien A. Hasan, Yasmin Liu, Hongtao Yenice, Kamil Aydogan, Bulent |
author_sort | Ahn, Kang-Hyun |
collection | PubMed |
description | PURPOSE: Total marrow irradiation (TMI) involves optimization of extremely large target volumes and requires extensive clinical experience and time for both treatment planning and delivery. Although volumetric modulated arc therapy (VMAT) achieves substantial reduction in treatment delivery time, planning process still presents a challenge due to use of multiple isocenters and multiple overlapping arcs. We developed and evaluated a knowledge-based planning (KBP) model for VMAT-TMI to address these clinical challenges. METHODS: Fifty-one patients previously treated in our clinic were selected for the model training, while 22 patients from another clinic were used as a test set. All plans used a 3-isocenter to cover sub-target volumes of head and neck (HN), chest, and pelvis. Chest plan was performed first and then used as the base dose for both the HN and pelvis plans to reduce hot spots around the field junctions. This resulted in a wide range of dose-volume histograms (DVH). To address this, plans without the base-dose plan were optimized and added to the library to train the model. RESULTS: KBP achieved our clinical goals (95% of PTV receives 100% of Rx) in a single day, which used to take 4-6 days of effort without KBP. Statistically significant reductions with KBP were observed in the mean dose values to brain, lungs, oral cavity and lenses. KBP substantially improved 105% dose spillage (14.1% ± 2.4% vs 31.8% ± 3.8%), conformity index (1.51 ± 0.06 vs 1.81 ± 0.12) and homogeneity index (1.25 ± 0.02 vs 1.33 ± 0.03). CONCLUSIONS: KBP improved dosimetric performance with uniform quality. It reduced dependence on planner experience and achieved a factor of 5 reduction in planning time to produce quality plans to allow its wide-spread clinical implementation. |
format | Online Article Text |
id | pubmed-9577613 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-95776132022-10-19 Knowledge-based planning for multi-isocenter VMAT total marrow irradiation Ahn, Kang-Hyun Rondelli, Damiano Koshy, Matthew Partouche, Julien A. Hasan, Yasmin Liu, Hongtao Yenice, Kamil Aydogan, Bulent Front Oncol Oncology PURPOSE: Total marrow irradiation (TMI) involves optimization of extremely large target volumes and requires extensive clinical experience and time for both treatment planning and delivery. Although volumetric modulated arc therapy (VMAT) achieves substantial reduction in treatment delivery time, planning process still presents a challenge due to use of multiple isocenters and multiple overlapping arcs. We developed and evaluated a knowledge-based planning (KBP) model for VMAT-TMI to address these clinical challenges. METHODS: Fifty-one patients previously treated in our clinic were selected for the model training, while 22 patients from another clinic were used as a test set. All plans used a 3-isocenter to cover sub-target volumes of head and neck (HN), chest, and pelvis. Chest plan was performed first and then used as the base dose for both the HN and pelvis plans to reduce hot spots around the field junctions. This resulted in a wide range of dose-volume histograms (DVH). To address this, plans without the base-dose plan were optimized and added to the library to train the model. RESULTS: KBP achieved our clinical goals (95% of PTV receives 100% of Rx) in a single day, which used to take 4-6 days of effort without KBP. Statistically significant reductions with KBP were observed in the mean dose values to brain, lungs, oral cavity and lenses. KBP substantially improved 105% dose spillage (14.1% ± 2.4% vs 31.8% ± 3.8%), conformity index (1.51 ± 0.06 vs 1.81 ± 0.12) and homogeneity index (1.25 ± 0.02 vs 1.33 ± 0.03). CONCLUSIONS: KBP improved dosimetric performance with uniform quality. It reduced dependence on planner experience and achieved a factor of 5 reduction in planning time to produce quality plans to allow its wide-spread clinical implementation. Frontiers Media S.A. 2022-10-04 /pmc/articles/PMC9577613/ /pubmed/36267964 http://dx.doi.org/10.3389/fonc.2022.942685 Text en Copyright © 2022 Ahn, Rondelli, Koshy, Partouche, Hasan, Liu, Yenice and Aydogan https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Oncology Ahn, Kang-Hyun Rondelli, Damiano Koshy, Matthew Partouche, Julien A. Hasan, Yasmin Liu, Hongtao Yenice, Kamil Aydogan, Bulent Knowledge-based planning for multi-isocenter VMAT total marrow irradiation |
title | Knowledge-based planning for multi-isocenter VMAT total marrow irradiation |
title_full | Knowledge-based planning for multi-isocenter VMAT total marrow irradiation |
title_fullStr | Knowledge-based planning for multi-isocenter VMAT total marrow irradiation |
title_full_unstemmed | Knowledge-based planning for multi-isocenter VMAT total marrow irradiation |
title_short | Knowledge-based planning for multi-isocenter VMAT total marrow irradiation |
title_sort | knowledge-based planning for multi-isocenter vmat total marrow irradiation |
topic | Oncology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9577613/ https://www.ncbi.nlm.nih.gov/pubmed/36267964 http://dx.doi.org/10.3389/fonc.2022.942685 |
work_keys_str_mv | AT ahnkanghyun knowledgebasedplanningformultiisocentervmattotalmarrowirradiation AT rondellidamiano knowledgebasedplanningformultiisocentervmattotalmarrowirradiation AT koshymatthew knowledgebasedplanningformultiisocentervmattotalmarrowirradiation AT partouchejuliena knowledgebasedplanningformultiisocentervmattotalmarrowirradiation AT hasanyasmin knowledgebasedplanningformultiisocentervmattotalmarrowirradiation AT liuhongtao knowledgebasedplanningformultiisocentervmattotalmarrowirradiation AT yenicekamil knowledgebasedplanningformultiisocentervmattotalmarrowirradiation AT aydoganbulent knowledgebasedplanningformultiisocentervmattotalmarrowirradiation |