Cargando…

Application value of joint STOP-Bang questionnaire and Epworth Sleepiness Scale in screening for obstructive sleep apnea

OBJECTIVE: This paper evaluates the application value of the STOP-Bang questionnaire combined with the Epworth Sleepiness Scale (ESS) in screening for obstructive sleep apnea (OSA) in the population. METHOD: Thousand-six hundred seventy-one patients with suspected OSA who visited the Sleep Medicine...

Descripción completa

Detalles Bibliográficos
Autores principales: Zheng, Zhenzhen, Zhang, Yitao, Chen, Mingdi, Chen, Xiaojuan, Li, Chunhe, Wang, Chaoyu, Zhu, Jinru, Lin, Junyan, Ou, Xudong, Zou, Zhihong, Wang, Zhiwei, Deng, Junzhong, Chen, Riken
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9578009/
https://www.ncbi.nlm.nih.gov/pubmed/36267990
http://dx.doi.org/10.3389/fpubh.2022.950585
_version_ 1784811885017694208
author Zheng, Zhenzhen
Zhang, Yitao
Chen, Mingdi
Chen, Xiaojuan
Li, Chunhe
Wang, Chaoyu
Zhu, Jinru
Lin, Junyan
Ou, Xudong
Zou, Zhihong
Wang, Zhiwei
Deng, Junzhong
Chen, Riken
author_facet Zheng, Zhenzhen
Zhang, Yitao
Chen, Mingdi
Chen, Xiaojuan
Li, Chunhe
Wang, Chaoyu
Zhu, Jinru
Lin, Junyan
Ou, Xudong
Zou, Zhihong
Wang, Zhiwei
Deng, Junzhong
Chen, Riken
author_sort Zheng, Zhenzhen
collection PubMed
description OBJECTIVE: This paper evaluates the application value of the STOP-Bang questionnaire combined with the Epworth Sleepiness Scale (ESS) in screening for obstructive sleep apnea (OSA) in the population. METHOD: Thousand-six hundred seventy-one patients with suspected OSA who visited the Sleep Medicine Center of the First Affiliated Hospital of Guangzhou Medical University from August 2017 to August 2020 were monitored by overnight polysomnography (PSG) after completing the ESS scale and STOP-Bang questionnaire. The sensitivity, specificity, positive predictive value, negative predictive value and receiver operating characteristic (ROC) curves of the two scales were calculated, and the accuracy in predicting OSA of the STOP-Bang questionnaire combined with ESS was analyzed. RESULTS: With Apnea Hypopnea Index (AHI) cutoffs of ≥5, ≥15 and ≥30 events/h, the areas under the ROC curve scored by STOP-Bang were 0.724, 0.703 and 0.712, and those of ESS were 0.632, 0.634 and 0.695; the diagnostic odds ratio (DOR) values of STOP-Bang for OSA, moderate to severe OSA, and severe OSA were 3.349, 2.651 and 3.189, and those of ESS were 2.665, 2.279 and 3.289. The STOP-Bang score of three was used as the cut-off point for OSA diagnosis with higher sensitivity and lower specificity, while ESS had higher specificity. STOP-Bang (≥3) combined with ESS significantly improved its specificity for predicting OSA. CONCLUSION: The STOP-Bang questionnaire is a simple and effective new tool for screening patients for OSA, while a STOP-Bang score of ≥3 combined with ESS can further improve its specificity. Thus, we suggest further screening with ESS after a STOP-Bang score of ≥3 in suspected patients.
format Online
Article
Text
id pubmed-9578009
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-95780092022-10-19 Application value of joint STOP-Bang questionnaire and Epworth Sleepiness Scale in screening for obstructive sleep apnea Zheng, Zhenzhen Zhang, Yitao Chen, Mingdi Chen, Xiaojuan Li, Chunhe Wang, Chaoyu Zhu, Jinru Lin, Junyan Ou, Xudong Zou, Zhihong Wang, Zhiwei Deng, Junzhong Chen, Riken Front Public Health Public Health OBJECTIVE: This paper evaluates the application value of the STOP-Bang questionnaire combined with the Epworth Sleepiness Scale (ESS) in screening for obstructive sleep apnea (OSA) in the population. METHOD: Thousand-six hundred seventy-one patients with suspected OSA who visited the Sleep Medicine Center of the First Affiliated Hospital of Guangzhou Medical University from August 2017 to August 2020 were monitored by overnight polysomnography (PSG) after completing the ESS scale and STOP-Bang questionnaire. The sensitivity, specificity, positive predictive value, negative predictive value and receiver operating characteristic (ROC) curves of the two scales were calculated, and the accuracy in predicting OSA of the STOP-Bang questionnaire combined with ESS was analyzed. RESULTS: With Apnea Hypopnea Index (AHI) cutoffs of ≥5, ≥15 and ≥30 events/h, the areas under the ROC curve scored by STOP-Bang were 0.724, 0.703 and 0.712, and those of ESS were 0.632, 0.634 and 0.695; the diagnostic odds ratio (DOR) values of STOP-Bang for OSA, moderate to severe OSA, and severe OSA were 3.349, 2.651 and 3.189, and those of ESS were 2.665, 2.279 and 3.289. The STOP-Bang score of three was used as the cut-off point for OSA diagnosis with higher sensitivity and lower specificity, while ESS had higher specificity. STOP-Bang (≥3) combined with ESS significantly improved its specificity for predicting OSA. CONCLUSION: The STOP-Bang questionnaire is a simple and effective new tool for screening patients for OSA, while a STOP-Bang score of ≥3 combined with ESS can further improve its specificity. Thus, we suggest further screening with ESS after a STOP-Bang score of ≥3 in suspected patients. Frontiers Media S.A. 2022-09-29 /pmc/articles/PMC9578009/ /pubmed/36267990 http://dx.doi.org/10.3389/fpubh.2022.950585 Text en Copyright © 2022 Zheng, Zhang, Chen, Chen, Li, Wang, Zhu, Lin, Ou, Zou, Wang, Deng and Chen. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Public Health
Zheng, Zhenzhen
Zhang, Yitao
Chen, Mingdi
Chen, Xiaojuan
Li, Chunhe
Wang, Chaoyu
Zhu, Jinru
Lin, Junyan
Ou, Xudong
Zou, Zhihong
Wang, Zhiwei
Deng, Junzhong
Chen, Riken
Application value of joint STOP-Bang questionnaire and Epworth Sleepiness Scale in screening for obstructive sleep apnea
title Application value of joint STOP-Bang questionnaire and Epworth Sleepiness Scale in screening for obstructive sleep apnea
title_full Application value of joint STOP-Bang questionnaire and Epworth Sleepiness Scale in screening for obstructive sleep apnea
title_fullStr Application value of joint STOP-Bang questionnaire and Epworth Sleepiness Scale in screening for obstructive sleep apnea
title_full_unstemmed Application value of joint STOP-Bang questionnaire and Epworth Sleepiness Scale in screening for obstructive sleep apnea
title_short Application value of joint STOP-Bang questionnaire and Epworth Sleepiness Scale in screening for obstructive sleep apnea
title_sort application value of joint stop-bang questionnaire and epworth sleepiness scale in screening for obstructive sleep apnea
topic Public Health
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9578009/
https://www.ncbi.nlm.nih.gov/pubmed/36267990
http://dx.doi.org/10.3389/fpubh.2022.950585
work_keys_str_mv AT zhengzhenzhen applicationvalueofjointstopbangquestionnaireandepworthsleepinessscaleinscreeningforobstructivesleepapnea
AT zhangyitao applicationvalueofjointstopbangquestionnaireandepworthsleepinessscaleinscreeningforobstructivesleepapnea
AT chenmingdi applicationvalueofjointstopbangquestionnaireandepworthsleepinessscaleinscreeningforobstructivesleepapnea
AT chenxiaojuan applicationvalueofjointstopbangquestionnaireandepworthsleepinessscaleinscreeningforobstructivesleepapnea
AT lichunhe applicationvalueofjointstopbangquestionnaireandepworthsleepinessscaleinscreeningforobstructivesleepapnea
AT wangchaoyu applicationvalueofjointstopbangquestionnaireandepworthsleepinessscaleinscreeningforobstructivesleepapnea
AT zhujinru applicationvalueofjointstopbangquestionnaireandepworthsleepinessscaleinscreeningforobstructivesleepapnea
AT linjunyan applicationvalueofjointstopbangquestionnaireandepworthsleepinessscaleinscreeningforobstructivesleepapnea
AT ouxudong applicationvalueofjointstopbangquestionnaireandepworthsleepinessscaleinscreeningforobstructivesleepapnea
AT zouzhihong applicationvalueofjointstopbangquestionnaireandepworthsleepinessscaleinscreeningforobstructivesleepapnea
AT wangzhiwei applicationvalueofjointstopbangquestionnaireandepworthsleepinessscaleinscreeningforobstructivesleepapnea
AT dengjunzhong applicationvalueofjointstopbangquestionnaireandepworthsleepinessscaleinscreeningforobstructivesleepapnea
AT chenriken applicationvalueofjointstopbangquestionnaireandepworthsleepinessscaleinscreeningforobstructivesleepapnea