Cargando…
Assessment of labially impacted canines traction mode with clear aligners vs. fixed appliance: A comparative study based on 3D finite element analysis
Purpose: The objective of this study was to evaluate and compare the biomechanical differences between clear aligner and fixed appliance in the traction of labially impacted canines based on 3D finite element analysis. Methods: A series of patient-oriented finite element models were constructed, inc...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9579379/ https://www.ncbi.nlm.nih.gov/pubmed/36277381 http://dx.doi.org/10.3389/fbioe.2022.1004223 |
_version_ | 1784812168188788736 |
---|---|
author | Xia, Qian He, Yao Jia, Lurong Wang, Chunjuan Wang, Weixu Wang, Chao Song, Jinlin Fan, Yubo |
author_facet | Xia, Qian He, Yao Jia, Lurong Wang, Chunjuan Wang, Weixu Wang, Chao Song, Jinlin Fan, Yubo |
author_sort | Xia, Qian |
collection | PubMed |
description | Purpose: The objective of this study was to evaluate and compare the biomechanical differences between clear aligner and fixed appliance in the traction of labially impacted canines based on 3D finite element analysis. Methods: A series of patient-oriented finite element models were constructed, including a maxillary dentition with a right labially canine, maxilla, periodontal ligaments, traction attachments, and clear aligners. The two most common clinical scenarios were investigated: Scenario A: impacted canine (distal) and Scenario B: impacted canine (mesial). For each clinical scenario, three traction models with clear aligners and one fixed appliance model were established. Results: In all four models, the impacted canines exhibited similar initial displacement tendencies of mesially rotated in Scenario A and distally rotated in Scenario B, and with small differences in periodontal ligament stress magnitude. However, the sum of the periodontal ligament stresses of the anchorage teeth in the clear aligner mode was in the range of 56.28–76.21 kPa and in the fixed appliance mode was in the range of 6.61–7.22 kPa. The maximum value of initial displacement of the anchorage teeth in the clear aligner mode was in the range of 13.71–19.72 μm, while in the fixed appliance mode was 3.10–3.92 μm. Conclusion: For impacted canines, clear aligner mode and fixed appliance mode have little difference in biomechanical effect. However, the anchorage teeth in the clear aligner mode endure higher stress and show a more pronounced displacement tendency. In addition, the biomechanical effects of different clear aligner traction models are various but not obvious. |
format | Online Article Text |
id | pubmed-9579379 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-95793792022-10-20 Assessment of labially impacted canines traction mode with clear aligners vs. fixed appliance: A comparative study based on 3D finite element analysis Xia, Qian He, Yao Jia, Lurong Wang, Chunjuan Wang, Weixu Wang, Chao Song, Jinlin Fan, Yubo Front Bioeng Biotechnol Bioengineering and Biotechnology Purpose: The objective of this study was to evaluate and compare the biomechanical differences between clear aligner and fixed appliance in the traction of labially impacted canines based on 3D finite element analysis. Methods: A series of patient-oriented finite element models were constructed, including a maxillary dentition with a right labially canine, maxilla, periodontal ligaments, traction attachments, and clear aligners. The two most common clinical scenarios were investigated: Scenario A: impacted canine (distal) and Scenario B: impacted canine (mesial). For each clinical scenario, three traction models with clear aligners and one fixed appliance model were established. Results: In all four models, the impacted canines exhibited similar initial displacement tendencies of mesially rotated in Scenario A and distally rotated in Scenario B, and with small differences in periodontal ligament stress magnitude. However, the sum of the periodontal ligament stresses of the anchorage teeth in the clear aligner mode was in the range of 56.28–76.21 kPa and in the fixed appliance mode was in the range of 6.61–7.22 kPa. The maximum value of initial displacement of the anchorage teeth in the clear aligner mode was in the range of 13.71–19.72 μm, while in the fixed appliance mode was 3.10–3.92 μm. Conclusion: For impacted canines, clear aligner mode and fixed appliance mode have little difference in biomechanical effect. However, the anchorage teeth in the clear aligner mode endure higher stress and show a more pronounced displacement tendency. In addition, the biomechanical effects of different clear aligner traction models are various but not obvious. Frontiers Media S.A. 2022-10-05 /pmc/articles/PMC9579379/ /pubmed/36277381 http://dx.doi.org/10.3389/fbioe.2022.1004223 Text en Copyright © 2022 Xia, He, Jia, Wang, Wang, Wang, Song and Fan. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Xia, Qian He, Yao Jia, Lurong Wang, Chunjuan Wang, Weixu Wang, Chao Song, Jinlin Fan, Yubo Assessment of labially impacted canines traction mode with clear aligners vs. fixed appliance: A comparative study based on 3D finite element analysis |
title | Assessment of labially impacted canines traction mode with clear aligners vs. fixed appliance: A comparative study based on 3D finite element analysis |
title_full | Assessment of labially impacted canines traction mode with clear aligners vs. fixed appliance: A comparative study based on 3D finite element analysis |
title_fullStr | Assessment of labially impacted canines traction mode with clear aligners vs. fixed appliance: A comparative study based on 3D finite element analysis |
title_full_unstemmed | Assessment of labially impacted canines traction mode with clear aligners vs. fixed appliance: A comparative study based on 3D finite element analysis |
title_short | Assessment of labially impacted canines traction mode with clear aligners vs. fixed appliance: A comparative study based on 3D finite element analysis |
title_sort | assessment of labially impacted canines traction mode with clear aligners vs. fixed appliance: a comparative study based on 3d finite element analysis |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9579379/ https://www.ncbi.nlm.nih.gov/pubmed/36277381 http://dx.doi.org/10.3389/fbioe.2022.1004223 |
work_keys_str_mv | AT xiaqian assessmentoflabiallyimpactedcaninestractionmodewithclearalignersvsfixedapplianceacomparativestudybasedon3dfiniteelementanalysis AT heyao assessmentoflabiallyimpactedcaninestractionmodewithclearalignersvsfixedapplianceacomparativestudybasedon3dfiniteelementanalysis AT jialurong assessmentoflabiallyimpactedcaninestractionmodewithclearalignersvsfixedapplianceacomparativestudybasedon3dfiniteelementanalysis AT wangchunjuan assessmentoflabiallyimpactedcaninestractionmodewithclearalignersvsfixedapplianceacomparativestudybasedon3dfiniteelementanalysis AT wangweixu assessmentoflabiallyimpactedcaninestractionmodewithclearalignersvsfixedapplianceacomparativestudybasedon3dfiniteelementanalysis AT wangchao assessmentoflabiallyimpactedcaninestractionmodewithclearalignersvsfixedapplianceacomparativestudybasedon3dfiniteelementanalysis AT songjinlin assessmentoflabiallyimpactedcaninestractionmodewithclearalignersvsfixedapplianceacomparativestudybasedon3dfiniteelementanalysis AT fanyubo assessmentoflabiallyimpactedcaninestractionmodewithclearalignersvsfixedapplianceacomparativestudybasedon3dfiniteelementanalysis |