Sigmoid isostiffness-lines: An in-vitro model for the assessment of aortic stenosis severity

INTRODUCTION: The aortic valve opening area (AVA), used to quantify aortic stenosis severity, depends on the transvalvular flow rate (Q). The currently accepted clinical echocardiographic method assumes a linear relation between AVA and Q. We studied whether a sigmoid model better describes this rel...

Descripción completa

Detalles Bibliográficos
Autores principales: Buffle, Eric, Stucki, Michael, Zheng, Shaokai, Chiarelli, Maxime, Seiler, Christian, Obrist, Dominik, de Marchi, Stefano F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9581204/
https://www.ncbi.nlm.nih.gov/pubmed/36277798
http://dx.doi.org/10.3389/fcvm.2022.960170
_version_ 1784812567136305152
author Buffle, Eric
Stucki, Michael
Zheng, Shaokai
Chiarelli, Maxime
Seiler, Christian
Obrist, Dominik
de Marchi, Stefano F.
author_facet Buffle, Eric
Stucki, Michael
Zheng, Shaokai
Chiarelli, Maxime
Seiler, Christian
Obrist, Dominik
de Marchi, Stefano F.
author_sort Buffle, Eric
collection PubMed
description INTRODUCTION: The aortic valve opening area (AVA), used to quantify aortic stenosis severity, depends on the transvalvular flow rate (Q). The currently accepted clinical echocardiographic method assumes a linear relation between AVA and Q. We studied whether a sigmoid model better describes this relation and determined “isostiffness-lines” across a wide flow spectrum, thus allowing building a nomogram for the non-invasive estimation of valve stiffness. METHODS: Both AVA and instantaneous Q (Q(inst)) were measured at 10 different mean cardiac outputs of porcine aortic valves mounted in a pulsatile flow loop. The valves' cusps were chemically stiffened to obtain three stiffness grades and the procedure was repeated for each grade. The relative stiffness was defined as the ratio between LV work at grade with the added stiffness and at native stiffness grade. [Formula: see text] corresponding to the selected [Formula: see text] of the highest 3 and 5 cardiac output values was predicted in K-fold cross-validation using sequentially a linear and a sigmoid model. The accuracy of each model was assessed with the Akaike information criterion (AIC). RESULTS: The sigmoid model predicted more accurately [Formula: see text] (AIC for prediction of AVA with [Formula: see text] of the 3 highest cardiac output values: –1,743 vs. –1,048; 5 highest cardiac output values: –1,471 vs. –878) than the linear model. CONCLUSION: This study suggests that the relation between AVA and Q can be better described by a sigmoid than a linear model. This construction of “isostiffness-lines” may be a useful method for the assessment of aortic stenosis in clinical echocardiography.
format Online
Article
Text
id pubmed-9581204
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-95812042022-10-20 Sigmoid isostiffness-lines: An in-vitro model for the assessment of aortic stenosis severity Buffle, Eric Stucki, Michael Zheng, Shaokai Chiarelli, Maxime Seiler, Christian Obrist, Dominik de Marchi, Stefano F. Front Cardiovasc Med Cardiovascular Medicine INTRODUCTION: The aortic valve opening area (AVA), used to quantify aortic stenosis severity, depends on the transvalvular flow rate (Q). The currently accepted clinical echocardiographic method assumes a linear relation between AVA and Q. We studied whether a sigmoid model better describes this relation and determined “isostiffness-lines” across a wide flow spectrum, thus allowing building a nomogram for the non-invasive estimation of valve stiffness. METHODS: Both AVA and instantaneous Q (Q(inst)) were measured at 10 different mean cardiac outputs of porcine aortic valves mounted in a pulsatile flow loop. The valves' cusps were chemically stiffened to obtain three stiffness grades and the procedure was repeated for each grade. The relative stiffness was defined as the ratio between LV work at grade with the added stiffness and at native stiffness grade. [Formula: see text] corresponding to the selected [Formula: see text] of the highest 3 and 5 cardiac output values was predicted in K-fold cross-validation using sequentially a linear and a sigmoid model. The accuracy of each model was assessed with the Akaike information criterion (AIC). RESULTS: The sigmoid model predicted more accurately [Formula: see text] (AIC for prediction of AVA with [Formula: see text] of the 3 highest cardiac output values: –1,743 vs. –1,048; 5 highest cardiac output values: –1,471 vs. –878) than the linear model. CONCLUSION: This study suggests that the relation between AVA and Q can be better described by a sigmoid than a linear model. This construction of “isostiffness-lines” may be a useful method for the assessment of aortic stenosis in clinical echocardiography. Frontiers Media S.A. 2022-10-05 /pmc/articles/PMC9581204/ /pubmed/36277798 http://dx.doi.org/10.3389/fcvm.2022.960170 Text en Copyright © 2022 Buffle, Stucki, Zheng, Chiarelli, Seiler, Obrist and de Marchi. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Cardiovascular Medicine
Buffle, Eric
Stucki, Michael
Zheng, Shaokai
Chiarelli, Maxime
Seiler, Christian
Obrist, Dominik
de Marchi, Stefano F.
Sigmoid isostiffness-lines: An in-vitro model for the assessment of aortic stenosis severity
title Sigmoid isostiffness-lines: An in-vitro model for the assessment of aortic stenosis severity
title_full Sigmoid isostiffness-lines: An in-vitro model for the assessment of aortic stenosis severity
title_fullStr Sigmoid isostiffness-lines: An in-vitro model for the assessment of aortic stenosis severity
title_full_unstemmed Sigmoid isostiffness-lines: An in-vitro model for the assessment of aortic stenosis severity
title_short Sigmoid isostiffness-lines: An in-vitro model for the assessment of aortic stenosis severity
title_sort sigmoid isostiffness-lines: an in-vitro model for the assessment of aortic stenosis severity
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9581204/
https://www.ncbi.nlm.nih.gov/pubmed/36277798
http://dx.doi.org/10.3389/fcvm.2022.960170
work_keys_str_mv AT buffleeric sigmoidisostiffnesslinesaninvitromodelfortheassessmentofaorticstenosisseverity
AT stuckimichael sigmoidisostiffnesslinesaninvitromodelfortheassessmentofaorticstenosisseverity
AT zhengshaokai sigmoidisostiffnesslinesaninvitromodelfortheassessmentofaorticstenosisseverity
AT chiarellimaxime sigmoidisostiffnesslinesaninvitromodelfortheassessmentofaorticstenosisseverity
AT seilerchristian sigmoidisostiffnesslinesaninvitromodelfortheassessmentofaorticstenosisseverity
AT obristdominik sigmoidisostiffnesslinesaninvitromodelfortheassessmentofaorticstenosisseverity
AT demarchistefanof sigmoidisostiffnesslinesaninvitromodelfortheassessmentofaorticstenosisseverity