Cargando…

Efficacy of intraoperative fluorescence imaging using indocyanine green‐containing gauze in identifying the appropriate dissection layer in laparoscopic intersphincteric resection: A case report

In laparoscopic intersphincteric resection, identifying the dissection layer near the anus is often difficult. We safely proceeded with it, using indocyanine green‐containing gauze on the anal side to remove the internal anal sphincter with indocyanine green fluorography.

Detalles Bibliográficos
Autores principales: Kumata, Hiroyuki, Onishi, Keisuke, Takayama, Tetsuro, Asami, Kengo, Obara, Noriyuki, Sugawara, Hirofumi, Haga, Izumi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9582673/
https://www.ncbi.nlm.nih.gov/pubmed/36276903
http://dx.doi.org/10.1002/ccr3.6356
_version_ 1784812894621270016
author Kumata, Hiroyuki
Onishi, Keisuke
Takayama, Tetsuro
Asami, Kengo
Obara, Noriyuki
Sugawara, Hirofumi
Haga, Izumi
author_facet Kumata, Hiroyuki
Onishi, Keisuke
Takayama, Tetsuro
Asami, Kengo
Obara, Noriyuki
Sugawara, Hirofumi
Haga, Izumi
author_sort Kumata, Hiroyuki
collection PubMed
description In laparoscopic intersphincteric resection, identifying the dissection layer near the anus is often difficult. We safely proceeded with it, using indocyanine green‐containing gauze on the anal side to remove the internal anal sphincter with indocyanine green fluorography.
format Online
Article
Text
id pubmed-9582673
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-95826732022-10-21 Efficacy of intraoperative fluorescence imaging using indocyanine green‐containing gauze in identifying the appropriate dissection layer in laparoscopic intersphincteric resection: A case report Kumata, Hiroyuki Onishi, Keisuke Takayama, Tetsuro Asami, Kengo Obara, Noriyuki Sugawara, Hirofumi Haga, Izumi Clin Case Rep Case Report In laparoscopic intersphincteric resection, identifying the dissection layer near the anus is often difficult. We safely proceeded with it, using indocyanine green‐containing gauze on the anal side to remove the internal anal sphincter with indocyanine green fluorography. John Wiley and Sons Inc. 2022-10-20 /pmc/articles/PMC9582673/ /pubmed/36276903 http://dx.doi.org/10.1002/ccr3.6356 Text en © 2022 The Authors. Clinical Case Reports published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Kumata, Hiroyuki
Onishi, Keisuke
Takayama, Tetsuro
Asami, Kengo
Obara, Noriyuki
Sugawara, Hirofumi
Haga, Izumi
Efficacy of intraoperative fluorescence imaging using indocyanine green‐containing gauze in identifying the appropriate dissection layer in laparoscopic intersphincteric resection: A case report
title Efficacy of intraoperative fluorescence imaging using indocyanine green‐containing gauze in identifying the appropriate dissection layer in laparoscopic intersphincteric resection: A case report
title_full Efficacy of intraoperative fluorescence imaging using indocyanine green‐containing gauze in identifying the appropriate dissection layer in laparoscopic intersphincteric resection: A case report
title_fullStr Efficacy of intraoperative fluorescence imaging using indocyanine green‐containing gauze in identifying the appropriate dissection layer in laparoscopic intersphincteric resection: A case report
title_full_unstemmed Efficacy of intraoperative fluorescence imaging using indocyanine green‐containing gauze in identifying the appropriate dissection layer in laparoscopic intersphincteric resection: A case report
title_short Efficacy of intraoperative fluorescence imaging using indocyanine green‐containing gauze in identifying the appropriate dissection layer in laparoscopic intersphincteric resection: A case report
title_sort efficacy of intraoperative fluorescence imaging using indocyanine green‐containing gauze in identifying the appropriate dissection layer in laparoscopic intersphincteric resection: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9582673/
https://www.ncbi.nlm.nih.gov/pubmed/36276903
http://dx.doi.org/10.1002/ccr3.6356
work_keys_str_mv AT kumatahiroyuki efficacyofintraoperativefluorescenceimagingusingindocyaninegreencontaininggauzeinidentifyingtheappropriatedissectionlayerinlaparoscopicintersphinctericresectionacasereport
AT onishikeisuke efficacyofintraoperativefluorescenceimagingusingindocyaninegreencontaininggauzeinidentifyingtheappropriatedissectionlayerinlaparoscopicintersphinctericresectionacasereport
AT takayamatetsuro efficacyofintraoperativefluorescenceimagingusingindocyaninegreencontaininggauzeinidentifyingtheappropriatedissectionlayerinlaparoscopicintersphinctericresectionacasereport
AT asamikengo efficacyofintraoperativefluorescenceimagingusingindocyaninegreencontaininggauzeinidentifyingtheappropriatedissectionlayerinlaparoscopicintersphinctericresectionacasereport
AT obaranoriyuki efficacyofintraoperativefluorescenceimagingusingindocyaninegreencontaininggauzeinidentifyingtheappropriatedissectionlayerinlaparoscopicintersphinctericresectionacasereport
AT sugawarahirofumi efficacyofintraoperativefluorescenceimagingusingindocyaninegreencontaininggauzeinidentifyingtheappropriatedissectionlayerinlaparoscopicintersphinctericresectionacasereport
AT hagaizumi efficacyofintraoperativefluorescenceimagingusingindocyaninegreencontaininggauzeinidentifyingtheappropriatedissectionlayerinlaparoscopicintersphinctericresectionacasereport