Cargando…

Accuracy and Precision of Acetabular Component Position Does Not Differ Between the Anterior and Posterior Approaches to Total Hip Arthroplasty With Robotic Assistance: A Matched-Pair Analysis

BACKGROUND: Deviation from planned component placement with robot-assisted total hip arthroplasty (RA-THA) may differ based on surgical approach. The purpose of this study was to compare radiographic accuracy and precision of acetabular component position using RA-THA with the direct anterior approa...

Descripción completa

Detalles Bibliográficos
Autores principales: Kunze, Kyle N., Huddleston, Hailey P., Romero, Joey, Chiu, Yu-Fen, Jerabek, Seth A., McLawhorn, Alexander S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9583454/
https://www.ncbi.nlm.nih.gov/pubmed/36275492
http://dx.doi.org/10.1016/j.artd.2022.08.004
_version_ 1784813075805765632
author Kunze, Kyle N.
Huddleston, Hailey P.
Romero, Joey
Chiu, Yu-Fen
Jerabek, Seth A.
McLawhorn, Alexander S.
author_facet Kunze, Kyle N.
Huddleston, Hailey P.
Romero, Joey
Chiu, Yu-Fen
Jerabek, Seth A.
McLawhorn, Alexander S.
author_sort Kunze, Kyle N.
collection PubMed
description BACKGROUND: Deviation from planned component placement with robot-assisted total hip arthroplasty (RA-THA) may differ based on surgical approach. The purpose of this study was to compare radiographic accuracy and precision of acetabular component position using RA-THA with the direct anterior approach (DAA) or posterior approach (PA). METHODS: Between 2016 and 2019, 134 PA RA-THA patients were matched to 134 DAA RA-THA patients based on age (±10 years), body mass index (±5 kg/m(2)), and sex (exact). Acetabular component position was assessed using (1) planned position on preoperative computed tomography, (2) intraoperative position, and (3) position on 6-week postoperative radiographs using the digital Ein Bild Röntgen Analyse system. RESULTS: Accuracy of acetabular component inclination in the PA cohort was lower than that in the DAA cohort (PA: 4.3° ± 2.8° vs DAA: 3.1° ± 2.4°, P = .001). Inclination precision was not statistically different (PA: 3° ± 2.4° vs DAA: 2.5° ± 1.8°, P = .071). Anteversion accuracy was not statistically different (PA: 4.1° ± 3.7° vs DAA: 3.5° ± 2.5°, P = .091). Acetabular component anteversion was more precise with DAA (PA: 4.1° ± 3.7° vs DAA: 2.9° ± 2.0°, P = .001). Radiographic outliers (anteversion or inclination was >10° or <−10° from the planned target) were significantly more prevalent in the PA cohort than in the DAA cohort (12 vs 3, P = .016). CONCLUSIONS: The acetabular component can be positioned with excellent precision and accuracy when using RA-THA regardless of approach. Although the DAA resulted in a slight increase in precise placement of cup anteversion and more accurate placement of cup abduction with fewer outliers, these small differences may not be clinically meaningful.
format Online
Article
Text
id pubmed-9583454
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-95834542022-10-21 Accuracy and Precision of Acetabular Component Position Does Not Differ Between the Anterior and Posterior Approaches to Total Hip Arthroplasty With Robotic Assistance: A Matched-Pair Analysis Kunze, Kyle N. Huddleston, Hailey P. Romero, Joey Chiu, Yu-Fen Jerabek, Seth A. McLawhorn, Alexander S. Arthroplast Today Original Research BACKGROUND: Deviation from planned component placement with robot-assisted total hip arthroplasty (RA-THA) may differ based on surgical approach. The purpose of this study was to compare radiographic accuracy and precision of acetabular component position using RA-THA with the direct anterior approach (DAA) or posterior approach (PA). METHODS: Between 2016 and 2019, 134 PA RA-THA patients were matched to 134 DAA RA-THA patients based on age (±10 years), body mass index (±5 kg/m(2)), and sex (exact). Acetabular component position was assessed using (1) planned position on preoperative computed tomography, (2) intraoperative position, and (3) position on 6-week postoperative radiographs using the digital Ein Bild Röntgen Analyse system. RESULTS: Accuracy of acetabular component inclination in the PA cohort was lower than that in the DAA cohort (PA: 4.3° ± 2.8° vs DAA: 3.1° ± 2.4°, P = .001). Inclination precision was not statistically different (PA: 3° ± 2.4° vs DAA: 2.5° ± 1.8°, P = .071). Anteversion accuracy was not statistically different (PA: 4.1° ± 3.7° vs DAA: 3.5° ± 2.5°, P = .091). Acetabular component anteversion was more precise with DAA (PA: 4.1° ± 3.7° vs DAA: 2.9° ± 2.0°, P = .001). Radiographic outliers (anteversion or inclination was >10° or <−10° from the planned target) were significantly more prevalent in the PA cohort than in the DAA cohort (12 vs 3, P = .016). CONCLUSIONS: The acetabular component can be positioned with excellent precision and accuracy when using RA-THA regardless of approach. Although the DAA resulted in a slight increase in precise placement of cup anteversion and more accurate placement of cup abduction with fewer outliers, these small differences may not be clinically meaningful. Elsevier 2022-10-18 /pmc/articles/PMC9583454/ /pubmed/36275492 http://dx.doi.org/10.1016/j.artd.2022.08.004 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Kunze, Kyle N.
Huddleston, Hailey P.
Romero, Joey
Chiu, Yu-Fen
Jerabek, Seth A.
McLawhorn, Alexander S.
Accuracy and Precision of Acetabular Component Position Does Not Differ Between the Anterior and Posterior Approaches to Total Hip Arthroplasty With Robotic Assistance: A Matched-Pair Analysis
title Accuracy and Precision of Acetabular Component Position Does Not Differ Between the Anterior and Posterior Approaches to Total Hip Arthroplasty With Robotic Assistance: A Matched-Pair Analysis
title_full Accuracy and Precision of Acetabular Component Position Does Not Differ Between the Anterior and Posterior Approaches to Total Hip Arthroplasty With Robotic Assistance: A Matched-Pair Analysis
title_fullStr Accuracy and Precision of Acetabular Component Position Does Not Differ Between the Anterior and Posterior Approaches to Total Hip Arthroplasty With Robotic Assistance: A Matched-Pair Analysis
title_full_unstemmed Accuracy and Precision of Acetabular Component Position Does Not Differ Between the Anterior and Posterior Approaches to Total Hip Arthroplasty With Robotic Assistance: A Matched-Pair Analysis
title_short Accuracy and Precision of Acetabular Component Position Does Not Differ Between the Anterior and Posterior Approaches to Total Hip Arthroplasty With Robotic Assistance: A Matched-Pair Analysis
title_sort accuracy and precision of acetabular component position does not differ between the anterior and posterior approaches to total hip arthroplasty with robotic assistance: a matched-pair analysis
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9583454/
https://www.ncbi.nlm.nih.gov/pubmed/36275492
http://dx.doi.org/10.1016/j.artd.2022.08.004
work_keys_str_mv AT kunzekylen accuracyandprecisionofacetabularcomponentpositiondoesnotdifferbetweentheanteriorandposteriorapproachestototalhiparthroplastywithroboticassistanceamatchedpairanalysis
AT huddlestonhaileyp accuracyandprecisionofacetabularcomponentpositiondoesnotdifferbetweentheanteriorandposteriorapproachestototalhiparthroplastywithroboticassistanceamatchedpairanalysis
AT romerojoey accuracyandprecisionofacetabularcomponentpositiondoesnotdifferbetweentheanteriorandposteriorapproachestototalhiparthroplastywithroboticassistanceamatchedpairanalysis
AT chiuyufen accuracyandprecisionofacetabularcomponentpositiondoesnotdifferbetweentheanteriorandposteriorapproachestototalhiparthroplastywithroboticassistanceamatchedpairanalysis
AT jerabeksetha accuracyandprecisionofacetabularcomponentpositiondoesnotdifferbetweentheanteriorandposteriorapproachestototalhiparthroplastywithroboticassistanceamatchedpairanalysis
AT mclawhornalexanders accuracyandprecisionofacetabularcomponentpositiondoesnotdifferbetweentheanteriorandposteriorapproachestototalhiparthroplastywithroboticassistanceamatchedpairanalysis