Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography

In this work, we integrated a commercially-available fully-spectroscopic pixelated cadmium telluride (CdTe) detector system as a two-dimensional (2D) array detector into our existing benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system. After integrating this detector, known as Hi...

Descripción completa

Detalles Bibliográficos
Autores principales: JAYARATHNA, SANDUN, MOKTAN, HEM, CHO, SANG HYUN
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9583747/
https://www.ncbi.nlm.nih.gov/pubmed/36274671
http://dx.doi.org/10.1109/access.2022.3210590
_version_ 1784813136262463488
author JAYARATHNA, SANDUN
MOKTAN, HEM
CHO, SANG HYUN
author_facet JAYARATHNA, SANDUN
MOKTAN, HEM
CHO, SANG HYUN
author_sort JAYARATHNA, SANDUN
collection PubMed
description In this work, we integrated a commercially-available fully-spectroscopic pixelated cadmium telluride (CdTe) detector system as a two-dimensional (2D) array detector into our existing benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system. After integrating this detector, known as High-Energy X-ray Imaging Technology (HEXITEC), we performed quantitative imaging of gold nanoparticle (GNP) distribution in a small animal-sized phantom using our benchtop XFCT system. Owing to the upgraded detector component within our benchtop XFCT system, we were able to conduct this phantom imaging in an unprecedented manner by volumetric XFCT scans followed by XFCT image reconstruction in 3D. The current results showed that adoption of HEXITEC, in conjunction with a custom-made parallel-hole collimator, drastically reduced the XFCT scan time/dose. Compared with the previous work performed with our original benchtop XFCT system adopting a single crystal CdTe detector, the currently observed reduction was up to a factor of 5, while achieving comparable GNP detection limit under similar experimental conditions. Overall, we demonstrated, for the first time to the best our knowledge, the feasibility of benchtop XFCT imaging of small animal-sized objects containing biologically relevant GNP concentrations (on the order of 0.1 mg Au/cm(3) or 100 parts-per-million/ppm), with the scan time (on the order of 1 minute)/x-ray dose (on the order of 10 cGy) that are likely meeting the minimum requirements for routine preclinical imaging applications.
format Online
Article
Text
id pubmed-9583747
institution National Center for Biotechnology Information
language English
publishDate 2022
record_format MEDLINE/PubMed
spelling pubmed-95837472022-10-20 Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography JAYARATHNA, SANDUN MOKTAN, HEM CHO, SANG HYUN IEEE Access Article In this work, we integrated a commercially-available fully-spectroscopic pixelated cadmium telluride (CdTe) detector system as a two-dimensional (2D) array detector into our existing benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system. After integrating this detector, known as High-Energy X-ray Imaging Technology (HEXITEC), we performed quantitative imaging of gold nanoparticle (GNP) distribution in a small animal-sized phantom using our benchtop XFCT system. Owing to the upgraded detector component within our benchtop XFCT system, we were able to conduct this phantom imaging in an unprecedented manner by volumetric XFCT scans followed by XFCT image reconstruction in 3D. The current results showed that adoption of HEXITEC, in conjunction with a custom-made parallel-hole collimator, drastically reduced the XFCT scan time/dose. Compared with the previous work performed with our original benchtop XFCT system adopting a single crystal CdTe detector, the currently observed reduction was up to a factor of 5, while achieving comparable GNP detection limit under similar experimental conditions. Overall, we demonstrated, for the first time to the best our knowledge, the feasibility of benchtop XFCT imaging of small animal-sized objects containing biologically relevant GNP concentrations (on the order of 0.1 mg Au/cm(3) or 100 parts-per-million/ppm), with the scan time (on the order of 1 minute)/x-ray dose (on the order of 10 cGy) that are likely meeting the minimum requirements for routine preclinical imaging applications. 2022 2022-09-28 /pmc/articles/PMC9583747/ /pubmed/36274671 http://dx.doi.org/10.1109/access.2022.3210590 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License. For more information, see https://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Article
JAYARATHNA, SANDUN
MOKTAN, HEM
CHO, SANG HYUN
Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography
title Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography
title_full Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography
title_fullStr Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography
title_full_unstemmed Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography
title_short Use of the Fully Spectroscopic Pixelated Cadmium Telluride Detector for Benchtop X-Ray Fluorescence Computed Tomography
title_sort use of the fully spectroscopic pixelated cadmium telluride detector for benchtop x-ray fluorescence computed tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9583747/
https://www.ncbi.nlm.nih.gov/pubmed/36274671
http://dx.doi.org/10.1109/access.2022.3210590
work_keys_str_mv AT jayarathnasandun useofthefullyspectroscopicpixelatedcadmiumtelluridedetectorforbenchtopxrayfluorescencecomputedtomography
AT moktanhem useofthefullyspectroscopicpixelatedcadmiumtelluridedetectorforbenchtopxrayfluorescencecomputedtomography
AT chosanghyun useofthefullyspectroscopicpixelatedcadmiumtelluridedetectorforbenchtopxrayfluorescencecomputedtomography