Cargando…
Quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated Pentacam Scheimpflug imaging analysis
Purpose: Slowing ectasia progression is critical for maintaining visual potential in keratoconus (KC), for which various therapeutic approaches have been implemented. A Pentacam Scheimpflug imaging device was used to quantify contact lens (CL)-related changes in keratoconus corneal topographic indic...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Romanian Society of Ophthalmology
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9585500/ https://www.ncbi.nlm.nih.gov/pubmed/36349169 http://dx.doi.org/10.22336/rjo.2022.47 |
_version_ | 1784813507004334080 |
---|---|
author | Kasıkcı, Murat Karalezli, Aylin Eroğul, Özgür Gobeka, Hamidu Hamisi |
author_facet | Kasıkcı, Murat Karalezli, Aylin Eroğul, Özgür Gobeka, Hamidu Hamisi |
author_sort | Kasıkcı, Murat |
collection | PubMed |
description | Purpose: Slowing ectasia progression is critical for maintaining visual potential in keratoconus (KC), for which various therapeutic approaches have been implemented. A Pentacam Scheimpflug imaging device was used to quantify contact lens (CL)-related changes in keratoconus corneal topographic indices. Methods: Thirty KC patients (group 1; 60 eyes) were using one of the three CL (rigid gas-permeable CL (RGPCL)-10, hybrid CL (HCL)-10, and scleral CL (SCL)-10 patients). A control group included 30 KC patients (group 2; 60 eyes) not using CLs due to intolerance or inappropriateness. The Pentacam® HR Scheimpflug imaging device was used to measure topographic indices such as Km anterior, Km posterior, K max, corneal thickness (CT, corneal central, apex, and thinnest), corneal volume (CV), anterior chamber volume (ACV), and anterior chamber depth (ACD) at baseline, 3rd, 6th, and 12th months. Results: The mean ages for groups 1 and 2 were 32±10 and 31±09 years, respectively. Group 1 had a lower but statistically significant change in K max than group 2 (p<0.038). Also, group 1 had a minor but non-significant decrease in anterior and posterior keratometry values compared to group 2 (pKm ant. right/ left eye = 0.063/ 0.065 and 0.087/ 0.094, respectively). RGPCL users had significant changes in central CT, thinnest CT and ACD (p<0.041). SCL users had more stable changes than other CLs for the thinnest CT along with significant changes in K max, pachy apex and ACV (p<0.036). HCL users had significantly higher K max stability (p<0.039). Conclusion: Regular use of appropriate therapeutic CLs may help to stabilize corneal deformity, thereby slowing changes in corneal topographic indices in KC. |
format | Online Article Text |
id | pubmed-9585500 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Romanian Society of Ophthalmology |
record_format | MEDLINE/PubMed |
spelling | pubmed-95855002022-11-07 Quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated Pentacam Scheimpflug imaging analysis Kasıkcı, Murat Karalezli, Aylin Eroğul, Özgür Gobeka, Hamidu Hamisi Rom J Ophthalmol General Articles Purpose: Slowing ectasia progression is critical for maintaining visual potential in keratoconus (KC), for which various therapeutic approaches have been implemented. A Pentacam Scheimpflug imaging device was used to quantify contact lens (CL)-related changes in keratoconus corneal topographic indices. Methods: Thirty KC patients (group 1; 60 eyes) were using one of the three CL (rigid gas-permeable CL (RGPCL)-10, hybrid CL (HCL)-10, and scleral CL (SCL)-10 patients). A control group included 30 KC patients (group 2; 60 eyes) not using CLs due to intolerance or inappropriateness. The Pentacam® HR Scheimpflug imaging device was used to measure topographic indices such as Km anterior, Km posterior, K max, corneal thickness (CT, corneal central, apex, and thinnest), corneal volume (CV), anterior chamber volume (ACV), and anterior chamber depth (ACD) at baseline, 3rd, 6th, and 12th months. Results: The mean ages for groups 1 and 2 were 32±10 and 31±09 years, respectively. Group 1 had a lower but statistically significant change in K max than group 2 (p<0.038). Also, group 1 had a minor but non-significant decrease in anterior and posterior keratometry values compared to group 2 (pKm ant. right/ left eye = 0.063/ 0.065 and 0.087/ 0.094, respectively). RGPCL users had significant changes in central CT, thinnest CT and ACD (p<0.041). SCL users had more stable changes than other CLs for the thinnest CT along with significant changes in K max, pachy apex and ACV (p<0.036). HCL users had significantly higher K max stability (p<0.039). Conclusion: Regular use of appropriate therapeutic CLs may help to stabilize corneal deformity, thereby slowing changes in corneal topographic indices in KC. Romanian Society of Ophthalmology 2022 /pmc/articles/PMC9585500/ /pubmed/36349169 http://dx.doi.org/10.22336/rjo.2022.47 Text en © The Authors.Romanian Society of Ophthalmology https://creativecommons.org/licenses/by/2.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | General Articles Kasıkcı, Murat Karalezli, Aylin Eroğul, Özgür Gobeka, Hamidu Hamisi Quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated Pentacam Scheimpflug imaging analysis |
title | Quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated Pentacam Scheimpflug imaging analysis
|
title_full | Quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated Pentacam Scheimpflug imaging analysis
|
title_fullStr | Quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated Pentacam Scheimpflug imaging analysis
|
title_full_unstemmed | Quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated Pentacam Scheimpflug imaging analysis
|
title_short | Quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated Pentacam Scheimpflug imaging analysis
|
title_sort | quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated pentacam scheimpflug imaging analysis |
topic | General Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9585500/ https://www.ncbi.nlm.nih.gov/pubmed/36349169 http://dx.doi.org/10.22336/rjo.2022.47 |
work_keys_str_mv | AT kasıkcımurat quantifyingcontactlensrelatedchangesinkeratoconuscornealtopographicindicesanupdatedpentacamscheimpflugimaginganalysis AT karalezliaylin quantifyingcontactlensrelatedchangesinkeratoconuscornealtopographicindicesanupdatedpentacamscheimpflugimaginganalysis AT erogulozgur quantifyingcontactlensrelatedchangesinkeratoconuscornealtopographicindicesanupdatedpentacamscheimpflugimaginganalysis AT gobekahamiduhamisi quantifyingcontactlensrelatedchangesinkeratoconuscornealtopographicindicesanupdatedpentacamscheimpflugimaginganalysis |