Cargando…

Quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated Pentacam Scheimpflug imaging analysis

Purpose: Slowing ectasia progression is critical for maintaining visual potential in keratoconus (KC), for which various therapeutic approaches have been implemented. A Pentacam Scheimpflug imaging device was used to quantify contact lens (CL)-related changes in keratoconus corneal topographic indic...

Descripción completa

Detalles Bibliográficos
Autores principales: Kasıkcı, Murat, Karalezli, Aylin, Eroğul, Özgür, Gobeka, Hamidu Hamisi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Romanian Society of Ophthalmology 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9585500/
https://www.ncbi.nlm.nih.gov/pubmed/36349169
http://dx.doi.org/10.22336/rjo.2022.47
_version_ 1784813507004334080
author Kasıkcı, Murat
Karalezli, Aylin
Eroğul, Özgür
Gobeka, Hamidu Hamisi
author_facet Kasıkcı, Murat
Karalezli, Aylin
Eroğul, Özgür
Gobeka, Hamidu Hamisi
author_sort Kasıkcı, Murat
collection PubMed
description Purpose: Slowing ectasia progression is critical for maintaining visual potential in keratoconus (KC), for which various therapeutic approaches have been implemented. A Pentacam Scheimpflug imaging device was used to quantify contact lens (CL)-related changes in keratoconus corneal topographic indices. Methods: Thirty KC patients (group 1; 60 eyes) were using one of the three CL (rigid gas-permeable CL (RGPCL)-10, hybrid CL (HCL)-10, and scleral CL (SCL)-10 patients). A control group included 30 KC patients (group 2; 60 eyes) not using CLs due to intolerance or inappropriateness. The Pentacam® HR Scheimpflug imaging device was used to measure topographic indices such as Km anterior, Km posterior, K max, corneal thickness (CT, corneal central, apex, and thinnest), corneal volume (CV), anterior chamber volume (ACV), and anterior chamber depth (ACD) at baseline, 3rd, 6th, and 12th months. Results: The mean ages for groups 1 and 2 were 32±10 and 31±09 years, respectively. Group 1 had a lower but statistically significant change in K max than group 2 (p<0.038). Also, group 1 had a minor but non-significant decrease in anterior and posterior keratometry values compared to group 2 (pKm ant. right/ left eye = 0.063/ 0.065 and 0.087/ 0.094, respectively). RGPCL users had significant changes in central CT, thinnest CT and ACD (p<0.041). SCL users had more stable changes than other CLs for the thinnest CT along with significant changes in K max, pachy apex and ACV (p<0.036). HCL users had significantly higher K max stability (p<0.039). Conclusion: Regular use of appropriate therapeutic CLs may help to stabilize corneal deformity, thereby slowing changes in corneal topographic indices in KC.
format Online
Article
Text
id pubmed-9585500
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Romanian Society of Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-95855002022-11-07 Quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated Pentacam Scheimpflug imaging analysis Kasıkcı, Murat Karalezli, Aylin Eroğul, Özgür Gobeka, Hamidu Hamisi Rom J Ophthalmol General Articles Purpose: Slowing ectasia progression is critical for maintaining visual potential in keratoconus (KC), for which various therapeutic approaches have been implemented. A Pentacam Scheimpflug imaging device was used to quantify contact lens (CL)-related changes in keratoconus corneal topographic indices. Methods: Thirty KC patients (group 1; 60 eyes) were using one of the three CL (rigid gas-permeable CL (RGPCL)-10, hybrid CL (HCL)-10, and scleral CL (SCL)-10 patients). A control group included 30 KC patients (group 2; 60 eyes) not using CLs due to intolerance or inappropriateness. The Pentacam® HR Scheimpflug imaging device was used to measure topographic indices such as Km anterior, Km posterior, K max, corneal thickness (CT, corneal central, apex, and thinnest), corneal volume (CV), anterior chamber volume (ACV), and anterior chamber depth (ACD) at baseline, 3rd, 6th, and 12th months. Results: The mean ages for groups 1 and 2 were 32±10 and 31±09 years, respectively. Group 1 had a lower but statistically significant change in K max than group 2 (p<0.038). Also, group 1 had a minor but non-significant decrease in anterior and posterior keratometry values compared to group 2 (pKm ant. right/ left eye = 0.063/ 0.065 and 0.087/ 0.094, respectively). RGPCL users had significant changes in central CT, thinnest CT and ACD (p<0.041). SCL users had more stable changes than other CLs for the thinnest CT along with significant changes in K max, pachy apex and ACV (p<0.036). HCL users had significantly higher K max stability (p<0.039). Conclusion: Regular use of appropriate therapeutic CLs may help to stabilize corneal deformity, thereby slowing changes in corneal topographic indices in KC. Romanian Society of Ophthalmology 2022 /pmc/articles/PMC9585500/ /pubmed/36349169 http://dx.doi.org/10.22336/rjo.2022.47 Text en © The Authors.Romanian Society of Ophthalmology https://creativecommons.org/licenses/by/2.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle General Articles
Kasıkcı, Murat
Karalezli, Aylin
Eroğul, Özgür
Gobeka, Hamidu Hamisi
Quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated Pentacam Scheimpflug imaging analysis
title Quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated Pentacam Scheimpflug imaging analysis
title_full Quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated Pentacam Scheimpflug imaging analysis
title_fullStr Quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated Pentacam Scheimpflug imaging analysis
title_full_unstemmed Quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated Pentacam Scheimpflug imaging analysis
title_short Quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated Pentacam Scheimpflug imaging analysis
title_sort quantifying contact lens-related changes in keratoconus corneal topographic indices: an updated pentacam scheimpflug imaging analysis
topic General Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9585500/
https://www.ncbi.nlm.nih.gov/pubmed/36349169
http://dx.doi.org/10.22336/rjo.2022.47
work_keys_str_mv AT kasıkcımurat quantifyingcontactlensrelatedchangesinkeratoconuscornealtopographicindicesanupdatedpentacamscheimpflugimaginganalysis
AT karalezliaylin quantifyingcontactlensrelatedchangesinkeratoconuscornealtopographicindicesanupdatedpentacamscheimpflugimaginganalysis
AT erogulozgur quantifyingcontactlensrelatedchangesinkeratoconuscornealtopographicindicesanupdatedpentacamscheimpflugimaginganalysis
AT gobekahamiduhamisi quantifyingcontactlensrelatedchangesinkeratoconuscornealtopographicindicesanupdatedpentacamscheimpflugimaginganalysis