Cargando…

Diagnostic Accuracy and Agreement Between Inter- and Intra-Observers in the Absence of Clinical History for Liquid-Based Preparation of Gynecology Specimens

CONTEXT: The clinical history in cytology is the best source of information to ensure the accuracy of diagnosis, facilitating a slide observer to interpret and relate their findings in screening gynecology slides. AIMS: This study aims to evaluate the performance of slide observers to screen-blinded...

Descripción completa

Detalles Bibliográficos
Autores principales: Roslan, Nur Amirah, Abu, Mohd Nazri, Ismail, Farid Ridhuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9585816/
https://www.ncbi.nlm.nih.gov/pubmed/36277808
http://dx.doi.org/10.4103/joc.joc_68_22
_version_ 1784813574647971840
author Roslan, Nur Amirah
Abu, Mohd Nazri
Ismail, Farid Ridhuan
author_facet Roslan, Nur Amirah
Abu, Mohd Nazri
Ismail, Farid Ridhuan
author_sort Roslan, Nur Amirah
collection PubMed
description CONTEXT: The clinical history in cytology is the best source of information to ensure the accuracy of diagnosis, facilitating a slide observer to interpret and relate their findings in screening gynecology slides. AIMS: This study aims to evaluate the performance of slide observers to screen-blinded gynecology slides without providing any information on clinical history. SETTING AND DESIGN: A correlational study design was conducted at the cytology laboratory, Universiti Teknologi MARA Selangor, Puncak Alam Campus. METHODS AND MATERIALS: Fity-seven liquid-based preparation slides from gynecology specimens were screened blindly by five slide observers among Medical Laboratory Technology students who completed the enrollment of the cytology course. STATISTICAL ANALYSIS USED: The inter- and intra-observer reliability testing was measured using the kappa value of Fleiss’ and Cohen's kappa value, respectively, while the diagnostic accuracy without a clinical history was determined by the receiver operating characteristic (ROC) curve. RESULTS: The value of Fleiss’ kappa (κ) was 0.221—this represents a fair strength of agreement between inter-observers. An intra-observer reliability test for each slide observer was analyzed using Cohen's kappa statistic and revealed that the kappa value varied between 0.116 and 0.696, indicating slight-to-substantial agreement between intra-observers. Additionally, the sensitivity value of 94.28%, specificity value of 72.40%, a positive predictive value (PPV) of 37.28%, a negative predictive value (NPV) of 72.40%, a likelihood ratio of 14.43, and the diagnostic accuracy of 75.09% were recorded. CONCLUSIONS: In conclusion, the students (slide observers) from the Centre of Medical Laboratory Technology Studies who took part in this study were able to interpret, classify, and diagnose the LBP gynecologic cytopathological cases into several categories (NILM and ECA) based on the 2001 Bethesda System reporting guideline.
format Online
Article
Text
id pubmed-9585816
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-95858162022-10-22 Diagnostic Accuracy and Agreement Between Inter- and Intra-Observers in the Absence of Clinical History for Liquid-Based Preparation of Gynecology Specimens Roslan, Nur Amirah Abu, Mohd Nazri Ismail, Farid Ridhuan J Cytol Original Article CONTEXT: The clinical history in cytology is the best source of information to ensure the accuracy of diagnosis, facilitating a slide observer to interpret and relate their findings in screening gynecology slides. AIMS: This study aims to evaluate the performance of slide observers to screen-blinded gynecology slides without providing any information on clinical history. SETTING AND DESIGN: A correlational study design was conducted at the cytology laboratory, Universiti Teknologi MARA Selangor, Puncak Alam Campus. METHODS AND MATERIALS: Fity-seven liquid-based preparation slides from gynecology specimens were screened blindly by five slide observers among Medical Laboratory Technology students who completed the enrollment of the cytology course. STATISTICAL ANALYSIS USED: The inter- and intra-observer reliability testing was measured using the kappa value of Fleiss’ and Cohen's kappa value, respectively, while the diagnostic accuracy without a clinical history was determined by the receiver operating characteristic (ROC) curve. RESULTS: The value of Fleiss’ kappa (κ) was 0.221—this represents a fair strength of agreement between inter-observers. An intra-observer reliability test for each slide observer was analyzed using Cohen's kappa statistic and revealed that the kappa value varied between 0.116 and 0.696, indicating slight-to-substantial agreement between intra-observers. Additionally, the sensitivity value of 94.28%, specificity value of 72.40%, a positive predictive value (PPV) of 37.28%, a negative predictive value (NPV) of 72.40%, a likelihood ratio of 14.43, and the diagnostic accuracy of 75.09% were recorded. CONCLUSIONS: In conclusion, the students (slide observers) from the Centre of Medical Laboratory Technology Studies who took part in this study were able to interpret, classify, and diagnose the LBP gynecologic cytopathological cases into several categories (NILM and ECA) based on the 2001 Bethesda System reporting guideline. Wolters Kluwer - Medknow 2022 2022-08-17 /pmc/articles/PMC9585816/ /pubmed/36277808 http://dx.doi.org/10.4103/joc.joc_68_22 Text en Copyright: © 2022 Journal of Cytology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Roslan, Nur Amirah
Abu, Mohd Nazri
Ismail, Farid Ridhuan
Diagnostic Accuracy and Agreement Between Inter- and Intra-Observers in the Absence of Clinical History for Liquid-Based Preparation of Gynecology Specimens
title Diagnostic Accuracy and Agreement Between Inter- and Intra-Observers in the Absence of Clinical History for Liquid-Based Preparation of Gynecology Specimens
title_full Diagnostic Accuracy and Agreement Between Inter- and Intra-Observers in the Absence of Clinical History for Liquid-Based Preparation of Gynecology Specimens
title_fullStr Diagnostic Accuracy and Agreement Between Inter- and Intra-Observers in the Absence of Clinical History for Liquid-Based Preparation of Gynecology Specimens
title_full_unstemmed Diagnostic Accuracy and Agreement Between Inter- and Intra-Observers in the Absence of Clinical History for Liquid-Based Preparation of Gynecology Specimens
title_short Diagnostic Accuracy and Agreement Between Inter- and Intra-Observers in the Absence of Clinical History for Liquid-Based Preparation of Gynecology Specimens
title_sort diagnostic accuracy and agreement between inter- and intra-observers in the absence of clinical history for liquid-based preparation of gynecology specimens
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9585816/
https://www.ncbi.nlm.nih.gov/pubmed/36277808
http://dx.doi.org/10.4103/joc.joc_68_22
work_keys_str_mv AT roslannuramirah diagnosticaccuracyandagreementbetweeninterandintraobserversintheabsenceofclinicalhistoryforliquidbasedpreparationofgynecologyspecimens
AT abumohdnazri diagnosticaccuracyandagreementbetweeninterandintraobserversintheabsenceofclinicalhistoryforliquidbasedpreparationofgynecologyspecimens
AT ismailfaridridhuan diagnosticaccuracyandagreementbetweeninterandintraobserversintheabsenceofclinicalhistoryforliquidbasedpreparationofgynecologyspecimens