Cargando…

A Chelating Resin of EDTA-Type Modified Cross-Linking Polystyrene to Preconcentrate Trace Metals for Seawater Detection

The determination of trace metals in seawater is an important project of marine environmental monitoring. However, the presence of many alkali metal ions with high concentration, such as sodium ion, seriously interferes with the detection limit and accuracy of atomic absorption spectrometry (AAS, fl...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Chao, Duan, Linna, Han, Mingchao, He, Hongwei, Yuan, Mengxiang, Wang, Hairong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9586797/
https://www.ncbi.nlm.nih.gov/pubmed/36275429
http://dx.doi.org/10.1155/2022/2080600
_version_ 1784813761605926912
author Li, Chao
Duan, Linna
Han, Mingchao
He, Hongwei
Yuan, Mengxiang
Wang, Hairong
author_facet Li, Chao
Duan, Linna
Han, Mingchao
He, Hongwei
Yuan, Mengxiang
Wang, Hairong
author_sort Li, Chao
collection PubMed
description The determination of trace metals in seawater is an important project of marine environmental monitoring. However, the presence of many alkali metal ions with high concentration, such as sodium ion, seriously interferes with the detection limit and accuracy of atomic absorption spectrometry (AAS, flame/graphite furnace integrated). The conventional chemical methods for the enrichment of trace metals are complex, and low boiling point organic solvents are used. In this paper, a kind of commercial cross-linked polystyrene resin microspheres was chloromethylated and aminated to introduce EDTA-type amino polycarboxylic groups and then loaded in a column as the absorption filler. A set of seawater pretreatment and enrichment devices was designed and assembled. The enriching process and conditions of trace Cu, Zn, Pb, and Cd in standard seawater were studied. 10 g of the modified resin could enrich the equivalent seawater and remove successfully the light metal ions. pH = 5∼9 and 0.2 mL/min of the flow rate were the suitable conditions for preconcentration. The enriched metal ions in the eluent were analyzed on the AAS. Compared with the conventional solvent method, the novel material and enrichment device have high preconcentration efficiency, strong anti-interference ability, and low cost and could be directly applied for routine seawater detection.
format Online
Article
Text
id pubmed-9586797
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-95867972022-10-22 A Chelating Resin of EDTA-Type Modified Cross-Linking Polystyrene to Preconcentrate Trace Metals for Seawater Detection Li, Chao Duan, Linna Han, Mingchao He, Hongwei Yuan, Mengxiang Wang, Hairong J Anal Methods Chem Research Article The determination of trace metals in seawater is an important project of marine environmental monitoring. However, the presence of many alkali metal ions with high concentration, such as sodium ion, seriously interferes with the detection limit and accuracy of atomic absorption spectrometry (AAS, flame/graphite furnace integrated). The conventional chemical methods for the enrichment of trace metals are complex, and low boiling point organic solvents are used. In this paper, a kind of commercial cross-linked polystyrene resin microspheres was chloromethylated and aminated to introduce EDTA-type amino polycarboxylic groups and then loaded in a column as the absorption filler. A set of seawater pretreatment and enrichment devices was designed and assembled. The enriching process and conditions of trace Cu, Zn, Pb, and Cd in standard seawater were studied. 10 g of the modified resin could enrich the equivalent seawater and remove successfully the light metal ions. pH = 5∼9 and 0.2 mL/min of the flow rate were the suitable conditions for preconcentration. The enriched metal ions in the eluent were analyzed on the AAS. Compared with the conventional solvent method, the novel material and enrichment device have high preconcentration efficiency, strong anti-interference ability, and low cost and could be directly applied for routine seawater detection. Hindawi 2022-10-14 /pmc/articles/PMC9586797/ /pubmed/36275429 http://dx.doi.org/10.1155/2022/2080600 Text en Copyright © 2022 Chao Li et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Li, Chao
Duan, Linna
Han, Mingchao
He, Hongwei
Yuan, Mengxiang
Wang, Hairong
A Chelating Resin of EDTA-Type Modified Cross-Linking Polystyrene to Preconcentrate Trace Metals for Seawater Detection
title A Chelating Resin of EDTA-Type Modified Cross-Linking Polystyrene to Preconcentrate Trace Metals for Seawater Detection
title_full A Chelating Resin of EDTA-Type Modified Cross-Linking Polystyrene to Preconcentrate Trace Metals for Seawater Detection
title_fullStr A Chelating Resin of EDTA-Type Modified Cross-Linking Polystyrene to Preconcentrate Trace Metals for Seawater Detection
title_full_unstemmed A Chelating Resin of EDTA-Type Modified Cross-Linking Polystyrene to Preconcentrate Trace Metals for Seawater Detection
title_short A Chelating Resin of EDTA-Type Modified Cross-Linking Polystyrene to Preconcentrate Trace Metals for Seawater Detection
title_sort chelating resin of edta-type modified cross-linking polystyrene to preconcentrate trace metals for seawater detection
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9586797/
https://www.ncbi.nlm.nih.gov/pubmed/36275429
http://dx.doi.org/10.1155/2022/2080600
work_keys_str_mv AT lichao achelatingresinofedtatypemodifiedcrosslinkingpolystyrenetopreconcentratetracemetalsforseawaterdetection
AT duanlinna achelatingresinofedtatypemodifiedcrosslinkingpolystyrenetopreconcentratetracemetalsforseawaterdetection
AT hanmingchao achelatingresinofedtatypemodifiedcrosslinkingpolystyrenetopreconcentratetracemetalsforseawaterdetection
AT hehongwei achelatingresinofedtatypemodifiedcrosslinkingpolystyrenetopreconcentratetracemetalsforseawaterdetection
AT yuanmengxiang achelatingresinofedtatypemodifiedcrosslinkingpolystyrenetopreconcentratetracemetalsforseawaterdetection
AT wanghairong achelatingresinofedtatypemodifiedcrosslinkingpolystyrenetopreconcentratetracemetalsforseawaterdetection
AT lichao chelatingresinofedtatypemodifiedcrosslinkingpolystyrenetopreconcentratetracemetalsforseawaterdetection
AT duanlinna chelatingresinofedtatypemodifiedcrosslinkingpolystyrenetopreconcentratetracemetalsforseawaterdetection
AT hanmingchao chelatingresinofedtatypemodifiedcrosslinkingpolystyrenetopreconcentratetracemetalsforseawaterdetection
AT hehongwei chelatingresinofedtatypemodifiedcrosslinkingpolystyrenetopreconcentratetracemetalsforseawaterdetection
AT yuanmengxiang chelatingresinofedtatypemodifiedcrosslinkingpolystyrenetopreconcentratetracemetalsforseawaterdetection
AT wanghairong chelatingresinofedtatypemodifiedcrosslinkingpolystyrenetopreconcentratetracemetalsforseawaterdetection