Cargando…
Evaluating Optical Quality of a New Hydrophilic Enhanced Monofocal Intraocular Lens and Comparison to the Monofocal Counterpart: An Optical Bench Analysis
INTRODUCTION: The aim of the study was to analyze the optical properties of a new hydrophilic enhanced monofocal intraocular lens (IOL) using optical bench analysis and compare it with its monofocal counterpart. METHODS: This laboratory study investigates the enhanced monofocal intraocular lens (L-3...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Healthcare
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9587156/ https://www.ncbi.nlm.nih.gov/pubmed/36040648 http://dx.doi.org/10.1007/s40123-022-00561-4 |
_version_ | 1784813845804482560 |
---|---|
author | Borkenstein, Andreas F. Borkenstein, Eva-Maria Schmid, Ruediger |
author_facet | Borkenstein, Andreas F. Borkenstein, Eva-Maria Schmid, Ruediger |
author_sort | Borkenstein, Andreas F. |
collection | PubMed |
description | INTRODUCTION: The aim of the study was to analyze the optical properties of a new hydrophilic enhanced monofocal intraocular lens (IOL) using optical bench analysis and compare it with its monofocal counterpart. METHODS: This laboratory study investigates the enhanced monofocal intraocular lens (L-333) and the monofocal counterpart (L-313) IOL by Teleon Surgical, Spankeren, Netherlands on the optical bench, using OptiSpheric IOL PRO2 (Trioptics, Germany) in order to assess the optical quality according to ISO 11979 with ISO-2 Cornea. IOLs (power 22.0 D) were evaluated regarding through frequency modulation transfer function (MTF), Strehl ratio (SR), and through focus MTF at 50 lp/mm using a 3.0-mm and a 4.5-mm aperture. Tilt and decentration were applied. In addition, wavefront measurements were obtained using WaveMaster® IOL 2 device (Trioptics, Germany) and analyzed. RESULTS: Centered: The MTF (mean) at 50 lp/mm (L-333/L-313) with 3.0 mm aperture was 0.606/0.724 and with 4.5 mm aperture 0.330/0.409. The SR (mean) with 3.0 mm aperture was 0.586/0.809 and with 4.5 mm aperture 0.330/0.348. Decentered by 1 mm: The MTF (mean) at 50 lp/mm (L-333/L-313) with 3.0 mm aperture was 0.485/0.705 and with 4.5 mm aperture 0.255/0.374. The SR (mean) with 3.0 mm aperture was 0.457/0.739 and with 4.5 mm aperture 0.185/0.268. Tilted by 5 degrees: The MTF (mean) at 50 lp/mm (L-333/L-313) with 3.0 mm aperture was 0.577/0.657 and with 4.5 mm aperture 0.345/0.336. The SR (mean) with 3.0 mm aperture was 0.583/0.702 and with 4.5 mm aperture 0.269/0.237. In through focus MTF and aperture of 3.0 mm, the L-333 showed a peak of 0.41 with some enlarged depth of power of about 2 D. For the aperture of 4.5 mm, the MTF values of L-313 and L-333 were slightly reduced; L-333 showed an MTF peak of 0.23 and some reduced depth of power of about 1.5 D. Wavefront measurements showed no major aberrations for the L-313, while a combination of moderate increase in Z 4-0 and Z 6-0 with opposite sign was revealed for the L-333. CONCLUSION: The enhanced monofocal Lentis Quantum (L-333) produces some enlarged depth of focus by combining spherical aberration of different order and opposite sign. The Lentis Quantum performs very well in comparison to the aspherical monofocal counterpart owing to its optical design. Results with large apertures were sufficient too, suggesting that the lens is a good option in eyes with a wide pupil and thus in refractive surgeries of young patients. |
format | Online Article Text |
id | pubmed-9587156 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Healthcare |
record_format | MEDLINE/PubMed |
spelling | pubmed-95871562022-11-29 Evaluating Optical Quality of a New Hydrophilic Enhanced Monofocal Intraocular Lens and Comparison to the Monofocal Counterpart: An Optical Bench Analysis Borkenstein, Andreas F. Borkenstein, Eva-Maria Schmid, Ruediger Ophthalmol Ther Original Research INTRODUCTION: The aim of the study was to analyze the optical properties of a new hydrophilic enhanced monofocal intraocular lens (IOL) using optical bench analysis and compare it with its monofocal counterpart. METHODS: This laboratory study investigates the enhanced monofocal intraocular lens (L-333) and the monofocal counterpart (L-313) IOL by Teleon Surgical, Spankeren, Netherlands on the optical bench, using OptiSpheric IOL PRO2 (Trioptics, Germany) in order to assess the optical quality according to ISO 11979 with ISO-2 Cornea. IOLs (power 22.0 D) were evaluated regarding through frequency modulation transfer function (MTF), Strehl ratio (SR), and through focus MTF at 50 lp/mm using a 3.0-mm and a 4.5-mm aperture. Tilt and decentration were applied. In addition, wavefront measurements were obtained using WaveMaster® IOL 2 device (Trioptics, Germany) and analyzed. RESULTS: Centered: The MTF (mean) at 50 lp/mm (L-333/L-313) with 3.0 mm aperture was 0.606/0.724 and with 4.5 mm aperture 0.330/0.409. The SR (mean) with 3.0 mm aperture was 0.586/0.809 and with 4.5 mm aperture 0.330/0.348. Decentered by 1 mm: The MTF (mean) at 50 lp/mm (L-333/L-313) with 3.0 mm aperture was 0.485/0.705 and with 4.5 mm aperture 0.255/0.374. The SR (mean) with 3.0 mm aperture was 0.457/0.739 and with 4.5 mm aperture 0.185/0.268. Tilted by 5 degrees: The MTF (mean) at 50 lp/mm (L-333/L-313) with 3.0 mm aperture was 0.577/0.657 and with 4.5 mm aperture 0.345/0.336. The SR (mean) with 3.0 mm aperture was 0.583/0.702 and with 4.5 mm aperture 0.269/0.237. In through focus MTF and aperture of 3.0 mm, the L-333 showed a peak of 0.41 with some enlarged depth of power of about 2 D. For the aperture of 4.5 mm, the MTF values of L-313 and L-333 were slightly reduced; L-333 showed an MTF peak of 0.23 and some reduced depth of power of about 1.5 D. Wavefront measurements showed no major aberrations for the L-313, while a combination of moderate increase in Z 4-0 and Z 6-0 with opposite sign was revealed for the L-333. CONCLUSION: The enhanced monofocal Lentis Quantum (L-333) produces some enlarged depth of focus by combining spherical aberration of different order and opposite sign. The Lentis Quantum performs very well in comparison to the aspherical monofocal counterpart owing to its optical design. Results with large apertures were sufficient too, suggesting that the lens is a good option in eyes with a wide pupil and thus in refractive surgeries of young patients. Springer Healthcare 2022-08-30 2022-12 /pmc/articles/PMC9587156/ /pubmed/36040648 http://dx.doi.org/10.1007/s40123-022-00561-4 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by-nc/4.0/Open AccessThis article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License, which permits any non-commercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) . |
spellingShingle | Original Research Borkenstein, Andreas F. Borkenstein, Eva-Maria Schmid, Ruediger Evaluating Optical Quality of a New Hydrophilic Enhanced Monofocal Intraocular Lens and Comparison to the Monofocal Counterpart: An Optical Bench Analysis |
title | Evaluating Optical Quality of a New Hydrophilic Enhanced Monofocal Intraocular Lens and Comparison to the Monofocal Counterpart: An Optical Bench Analysis |
title_full | Evaluating Optical Quality of a New Hydrophilic Enhanced Monofocal Intraocular Lens and Comparison to the Monofocal Counterpart: An Optical Bench Analysis |
title_fullStr | Evaluating Optical Quality of a New Hydrophilic Enhanced Monofocal Intraocular Lens and Comparison to the Monofocal Counterpart: An Optical Bench Analysis |
title_full_unstemmed | Evaluating Optical Quality of a New Hydrophilic Enhanced Monofocal Intraocular Lens and Comparison to the Monofocal Counterpart: An Optical Bench Analysis |
title_short | Evaluating Optical Quality of a New Hydrophilic Enhanced Monofocal Intraocular Lens and Comparison to the Monofocal Counterpart: An Optical Bench Analysis |
title_sort | evaluating optical quality of a new hydrophilic enhanced monofocal intraocular lens and comparison to the monofocal counterpart: an optical bench analysis |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9587156/ https://www.ncbi.nlm.nih.gov/pubmed/36040648 http://dx.doi.org/10.1007/s40123-022-00561-4 |
work_keys_str_mv | AT borkensteinandreasf evaluatingopticalqualityofanewhydrophilicenhancedmonofocalintraocularlensandcomparisontothemonofocalcounterpartanopticalbenchanalysis AT borkensteinevamaria evaluatingopticalqualityofanewhydrophilicenhancedmonofocalintraocularlensandcomparisontothemonofocalcounterpartanopticalbenchanalysis AT schmidruediger evaluatingopticalqualityofanewhydrophilicenhancedmonofocalintraocularlensandcomparisontothemonofocalcounterpartanopticalbenchanalysis |