Cargando…
The Relationship Between BMI and Lung Function in Populations with Different Characteristics: A Cross-Sectional Study Based on the Enjoying Breathing Program in China
PURPOSE: To analyze the relationship between body mass index (BMI) and lung function, which may help optimize the screening and management process for chronic obstructive pulmonary disease (COPD) in the early stages. PATIENTS AND METHODS: In this cross-sectional study using data from the Enjoying Br...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9587705/ https://www.ncbi.nlm.nih.gov/pubmed/36281228 http://dx.doi.org/10.2147/COPD.S378247 |
Sumario: | PURPOSE: To analyze the relationship between body mass index (BMI) and lung function, which may help optimize the screening and management process for chronic obstructive pulmonary disease (COPD) in the early stages. PATIENTS AND METHODS: In this cross-sectional study using data from the Enjoying Breathing Program in China, participants were divided into two groups according to COPD Screening Questionnaire (COPD-SQ) scores (at risk and not at risk of COPD) and three groups based on lung function (normal lung function, preserved ratio impaired spirometry [PRISm], and obstructive lung function). RESULTS: A total of 32,033 subjects were enrolled in the current analysis. First, in people at risk of COPD, overweight and obese participants had better forced expiratory volume in one second (FEV1; overweight: 0.33 liters (l), 95% confidence interval [CI]: 0.27 to 0.38; obesity: 0.31 L, 95% CI: 0.22 to 0.39) values than the normal BMI group. Second, among people with PRISm, underweight participants had a lower FEV1 (−0.56 L, 95% CI: −0.86 to −0.26) and forced vital capacity (FVC; −0.33 L, 95% CI: −0.55 to −0.11) than participants with a normal weight, and obese participants had a higher FEV1 (0.22 L, 95% CI: 0.02 to 0.42) and FVC (0.16 L, 95% CI: 0.02 to 0.30) than participants with a normal weight. Taking normal BMI as the reference group, lower FEV1 (−0.80 L, 95% CI: −0.97 to −0.63) and FVC (−0.53 L, 95% CI: −0.64 to −0.42) were found in underweight participants with obstructive spirometry, and better FEV1 (obesity: 0.26 L, 95% CI: 0.12 to 0.40) was found in obese participants with obstructive spirometry. CONCLUSION: Being underweight and severely obese are associated with reduced lung function. Slight obesity was shown to be a protective factor for lung function in people at risk of COPD and those with PRISm. |
---|