Cargando…

At‐home end‐tidal carbon dioxide measurement in children with invasive home mechanical ventilation

BACKGROUND: Carbon dioxide concentration trending is used in chronic management of children with invasive home mechanical ventilation (HMV) in clinical settings, but options for end‐tidal carbon dioxide (EtCO(2)) monitoring at home are limited. We hypothesized that a palm‐sized, portable endotrachea...

Descripción completa

Detalles Bibliográficos
Autores principales: Foster, Carolyn C., Kwon, Soyang, Shah, Avani V., Hodgson, Caroline A., Hird‐McCorry, Lindsey P., Janus, Angela, Jedraszko, Aneta M., Swanson, Philip, Davis, Matthew M., Goodman, Denise M., Laguna, Theresa A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9588689/
https://www.ncbi.nlm.nih.gov/pubmed/35959530
http://dx.doi.org/10.1002/ppul.26092
_version_ 1784814147654909952
author Foster, Carolyn C.
Kwon, Soyang
Shah, Avani V.
Hodgson, Caroline A.
Hird‐McCorry, Lindsey P.
Janus, Angela
Jedraszko, Aneta M.
Swanson, Philip
Davis, Matthew M.
Goodman, Denise M.
Laguna, Theresa A.
author_facet Foster, Carolyn C.
Kwon, Soyang
Shah, Avani V.
Hodgson, Caroline A.
Hird‐McCorry, Lindsey P.
Janus, Angela
Jedraszko, Aneta M.
Swanson, Philip
Davis, Matthew M.
Goodman, Denise M.
Laguna, Theresa A.
author_sort Foster, Carolyn C.
collection PubMed
description BACKGROUND: Carbon dioxide concentration trending is used in chronic management of children with invasive home mechanical ventilation (HMV) in clinical settings, but options for end‐tidal carbon dioxide (EtCO(2)) monitoring at home are limited. We hypothesized that a palm‐sized, portable endotracheal capnograph (PEC) that measures EtCO(2) could be adapted for in‐home use in children with HMV. METHODS: We evaluated the internal consistency of the PEC by calculating an intraclass correlation coefficient of three back‐to‐back breaths by children (0–17 years) at baseline health in the clinic. Pearson's correlation was calculated for PEC EtCO(2) values with concurrent mean values of in‐clinic EtCO(2) and transcutaneous CO(2) (TCM) capnometers. The Bland–Altman test determined their level of agreement. Qualitative interviews and surveys assessed usability and acceptability by family‐caregivers at home. RESULTS: CO(2) values were collected in awake children in varied activity levels and positions (N = 30). The intraclass correlation coefficient for the PEC was 0.95 (p < 0.05). The correlation between the PEC and in‐clinic EtCO(2) device was 0.85 with a mean difference of −3.8 mmHg and precision of ±1.1 mmHg. The correlation between the PEC and the clinic TCM device was 0.92 with a mean difference of 0.2 mmHg and precision of ±1.0. Family‐caregivers (N = 10) trialed the PEC at home; all were able to obtain measurements at home while children were awake and sometimes asleep. CONCLUSIONS: A portable, noninvasive device for measuring EtCO(2) was feasible and acceptable, with values that trend similarly to currently in‐practice, outpatient models. These devices may facilitate monitoring of EtCO(2) at home in children with invasive HMV.
format Online
Article
Text
id pubmed-9588689
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-95886892023-01-03 At‐home end‐tidal carbon dioxide measurement in children with invasive home mechanical ventilation Foster, Carolyn C. Kwon, Soyang Shah, Avani V. Hodgson, Caroline A. Hird‐McCorry, Lindsey P. Janus, Angela Jedraszko, Aneta M. Swanson, Philip Davis, Matthew M. Goodman, Denise M. Laguna, Theresa A. Pediatr Pulmonol Original Articles BACKGROUND: Carbon dioxide concentration trending is used in chronic management of children with invasive home mechanical ventilation (HMV) in clinical settings, but options for end‐tidal carbon dioxide (EtCO(2)) monitoring at home are limited. We hypothesized that a palm‐sized, portable endotracheal capnograph (PEC) that measures EtCO(2) could be adapted for in‐home use in children with HMV. METHODS: We evaluated the internal consistency of the PEC by calculating an intraclass correlation coefficient of three back‐to‐back breaths by children (0–17 years) at baseline health in the clinic. Pearson's correlation was calculated for PEC EtCO(2) values with concurrent mean values of in‐clinic EtCO(2) and transcutaneous CO(2) (TCM) capnometers. The Bland–Altman test determined their level of agreement. Qualitative interviews and surveys assessed usability and acceptability by family‐caregivers at home. RESULTS: CO(2) values were collected in awake children in varied activity levels and positions (N = 30). The intraclass correlation coefficient for the PEC was 0.95 (p < 0.05). The correlation between the PEC and in‐clinic EtCO(2) device was 0.85 with a mean difference of −3.8 mmHg and precision of ±1.1 mmHg. The correlation between the PEC and the clinic TCM device was 0.92 with a mean difference of 0.2 mmHg and precision of ±1.0. Family‐caregivers (N = 10) trialed the PEC at home; all were able to obtain measurements at home while children were awake and sometimes asleep. CONCLUSIONS: A portable, noninvasive device for measuring EtCO(2) was feasible and acceptable, with values that trend similarly to currently in‐practice, outpatient models. These devices may facilitate monitoring of EtCO(2) at home in children with invasive HMV. John Wiley and Sons Inc. 2022-08-24 2022-11 /pmc/articles/PMC9588689/ /pubmed/35959530 http://dx.doi.org/10.1002/ppul.26092 Text en © 2022 The Authors. Pediatric Pulmonology published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Articles
Foster, Carolyn C.
Kwon, Soyang
Shah, Avani V.
Hodgson, Caroline A.
Hird‐McCorry, Lindsey P.
Janus, Angela
Jedraszko, Aneta M.
Swanson, Philip
Davis, Matthew M.
Goodman, Denise M.
Laguna, Theresa A.
At‐home end‐tidal carbon dioxide measurement in children with invasive home mechanical ventilation
title At‐home end‐tidal carbon dioxide measurement in children with invasive home mechanical ventilation
title_full At‐home end‐tidal carbon dioxide measurement in children with invasive home mechanical ventilation
title_fullStr At‐home end‐tidal carbon dioxide measurement in children with invasive home mechanical ventilation
title_full_unstemmed At‐home end‐tidal carbon dioxide measurement in children with invasive home mechanical ventilation
title_short At‐home end‐tidal carbon dioxide measurement in children with invasive home mechanical ventilation
title_sort at‐home end‐tidal carbon dioxide measurement in children with invasive home mechanical ventilation
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9588689/
https://www.ncbi.nlm.nih.gov/pubmed/35959530
http://dx.doi.org/10.1002/ppul.26092
work_keys_str_mv AT fostercarolync athomeendtidalcarbondioxidemeasurementinchildrenwithinvasivehomemechanicalventilation
AT kwonsoyang athomeendtidalcarbondioxidemeasurementinchildrenwithinvasivehomemechanicalventilation
AT shahavaniv athomeendtidalcarbondioxidemeasurementinchildrenwithinvasivehomemechanicalventilation
AT hodgsoncarolinea athomeendtidalcarbondioxidemeasurementinchildrenwithinvasivehomemechanicalventilation
AT hirdmccorrylindseyp athomeendtidalcarbondioxidemeasurementinchildrenwithinvasivehomemechanicalventilation
AT janusangela athomeendtidalcarbondioxidemeasurementinchildrenwithinvasivehomemechanicalventilation
AT jedraszkoanetam athomeendtidalcarbondioxidemeasurementinchildrenwithinvasivehomemechanicalventilation
AT swansonphilip athomeendtidalcarbondioxidemeasurementinchildrenwithinvasivehomemechanicalventilation
AT davismatthewm athomeendtidalcarbondioxidemeasurementinchildrenwithinvasivehomemechanicalventilation
AT goodmandenisem athomeendtidalcarbondioxidemeasurementinchildrenwithinvasivehomemechanicalventilation
AT lagunatheresaa athomeendtidalcarbondioxidemeasurementinchildrenwithinvasivehomemechanicalventilation