Cargando…
Head-to-head comparison of commercial artificial intelligence solutions for detection of large vessel occlusion at a comprehensive stroke center
PURPOSE: Despite the availability of commercial artificial intelligence (AI) tools for large vessel occlusion (LVO) detection, there is paucity of data comparing traditional machine learning and deep learning solutions in a real-world setting. The purpose of this study is to compare and validate the...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9588973/ https://www.ncbi.nlm.nih.gov/pubmed/36299266 http://dx.doi.org/10.3389/fneur.2022.1026609 |
_version_ | 1784814193945346048 |
---|---|
author | Schlossman, Jacob Ro, Daniel Salehi, Shirin Chow, Daniel Yu, Wengui Chang, Peter D. Soun, Jennifer E. |
author_facet | Schlossman, Jacob Ro, Daniel Salehi, Shirin Chow, Daniel Yu, Wengui Chang, Peter D. Soun, Jennifer E. |
author_sort | Schlossman, Jacob |
collection | PubMed |
description | PURPOSE: Despite the availability of commercial artificial intelligence (AI) tools for large vessel occlusion (LVO) detection, there is paucity of data comparing traditional machine learning and deep learning solutions in a real-world setting. The purpose of this study is to compare and validate the performance of two AI-based tools (RAPID LVO and CINA LVO) for LVO detection. MATERIALS AND METHODS: This was a retrospective, single center study performed at a comprehensive stroke center from December 2020 to June 2021. CT angiography (n = 263) for suspected stroke were evaluated for LVO. RAPID LVO is a traditional machine learning model which primarily relies on vessel density threshold assessment, while CINA LVO is an end-to-end deep learning tool implemented with multiple neural networks for detection and localization tasks. Reasons for errors were also recorded. RESULTS: There were 29 positive and 224 negative LVO cases by ground truth assessment. RAPID LVO demonstrated an accuracy of 0.86, sensitivity of 0.90, specificity of 0.86, positive predictive value of 0.45, and negative predictive value of 0.98, while CINA demonstrated an accuracy of 0.96, sensitivity of 0.76, specificity of 0.98, positive predictive value of 0.85, and negative predictive value of 0.97. CONCLUSION: Both tools successfully detected most anterior circulation occlusions. RAPID LVO had higher sensitivity while CINA LVO had higher accuracy and specificity. Interestingly, both tools were able to detect some, but not all M2 MCA occlusions. This is the first study to compare traditional and deep learning LVO tools in the clinical setting. |
format | Online Article Text |
id | pubmed-9588973 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-95889732022-10-25 Head-to-head comparison of commercial artificial intelligence solutions for detection of large vessel occlusion at a comprehensive stroke center Schlossman, Jacob Ro, Daniel Salehi, Shirin Chow, Daniel Yu, Wengui Chang, Peter D. Soun, Jennifer E. Front Neurol Neurology PURPOSE: Despite the availability of commercial artificial intelligence (AI) tools for large vessel occlusion (LVO) detection, there is paucity of data comparing traditional machine learning and deep learning solutions in a real-world setting. The purpose of this study is to compare and validate the performance of two AI-based tools (RAPID LVO and CINA LVO) for LVO detection. MATERIALS AND METHODS: This was a retrospective, single center study performed at a comprehensive stroke center from December 2020 to June 2021. CT angiography (n = 263) for suspected stroke were evaluated for LVO. RAPID LVO is a traditional machine learning model which primarily relies on vessel density threshold assessment, while CINA LVO is an end-to-end deep learning tool implemented with multiple neural networks for detection and localization tasks. Reasons for errors were also recorded. RESULTS: There were 29 positive and 224 negative LVO cases by ground truth assessment. RAPID LVO demonstrated an accuracy of 0.86, sensitivity of 0.90, specificity of 0.86, positive predictive value of 0.45, and negative predictive value of 0.98, while CINA demonstrated an accuracy of 0.96, sensitivity of 0.76, specificity of 0.98, positive predictive value of 0.85, and negative predictive value of 0.97. CONCLUSION: Both tools successfully detected most anterior circulation occlusions. RAPID LVO had higher sensitivity while CINA LVO had higher accuracy and specificity. Interestingly, both tools were able to detect some, but not all M2 MCA occlusions. This is the first study to compare traditional and deep learning LVO tools in the clinical setting. Frontiers Media S.A. 2022-10-10 /pmc/articles/PMC9588973/ /pubmed/36299266 http://dx.doi.org/10.3389/fneur.2022.1026609 Text en Copyright © 2022 Schlossman, Ro, Salehi, Chow, Yu, Chang and Soun. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Neurology Schlossman, Jacob Ro, Daniel Salehi, Shirin Chow, Daniel Yu, Wengui Chang, Peter D. Soun, Jennifer E. Head-to-head comparison of commercial artificial intelligence solutions for detection of large vessel occlusion at a comprehensive stroke center |
title | Head-to-head comparison of commercial artificial intelligence solutions for detection of large vessel occlusion at a comprehensive stroke center |
title_full | Head-to-head comparison of commercial artificial intelligence solutions for detection of large vessel occlusion at a comprehensive stroke center |
title_fullStr | Head-to-head comparison of commercial artificial intelligence solutions for detection of large vessel occlusion at a comprehensive stroke center |
title_full_unstemmed | Head-to-head comparison of commercial artificial intelligence solutions for detection of large vessel occlusion at a comprehensive stroke center |
title_short | Head-to-head comparison of commercial artificial intelligence solutions for detection of large vessel occlusion at a comprehensive stroke center |
title_sort | head-to-head comparison of commercial artificial intelligence solutions for detection of large vessel occlusion at a comprehensive stroke center |
topic | Neurology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9588973/ https://www.ncbi.nlm.nih.gov/pubmed/36299266 http://dx.doi.org/10.3389/fneur.2022.1026609 |
work_keys_str_mv | AT schlossmanjacob headtoheadcomparisonofcommercialartificialintelligencesolutionsfordetectionoflargevesselocclusionatacomprehensivestrokecenter AT rodaniel headtoheadcomparisonofcommercialartificialintelligencesolutionsfordetectionoflargevesselocclusionatacomprehensivestrokecenter AT salehishirin headtoheadcomparisonofcommercialartificialintelligencesolutionsfordetectionoflargevesselocclusionatacomprehensivestrokecenter AT chowdaniel headtoheadcomparisonofcommercialartificialintelligencesolutionsfordetectionoflargevesselocclusionatacomprehensivestrokecenter AT yuwengui headtoheadcomparisonofcommercialartificialintelligencesolutionsfordetectionoflargevesselocclusionatacomprehensivestrokecenter AT changpeterd headtoheadcomparisonofcommercialartificialintelligencesolutionsfordetectionoflargevesselocclusionatacomprehensivestrokecenter AT sounjennifere headtoheadcomparisonofcommercialartificialintelligencesolutionsfordetectionoflargevesselocclusionatacomprehensivestrokecenter |