Cargando…

Assessment of Surface and Build-up Doses for a 6 MV Photon Beam using Parallel Plate Chamber, EBT3 Gafchromic Films, and PRIMO Monte Carlo Simulation Code

BACKGROUND: Accurate assessment of surface and build-up doses has a key role in radiotherapy, especially for the superficial lesions with uncertainties involved while performing measurements in the build-up region. OBJECTIVE: This study aimed to assess surface and build-up doses for 6 MV photon beam...

Descripción completa

Detalles Bibliográficos
Autores principales: Mahur, Mamta, Singh, Munendra, Gurjar, Om Prakash, Semwal, Manoj Kumar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shiraz University of Medical Sciences 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9589075/
https://www.ncbi.nlm.nih.gov/pubmed/36313413
http://dx.doi.org/10.31661/jbpe.v0i0.2101-1274
_version_ 1784814219482365952
author Mahur, Mamta
Singh, Munendra
Gurjar, Om Prakash
Semwal, Manoj Kumar
author_facet Mahur, Mamta
Singh, Munendra
Gurjar, Om Prakash
Semwal, Manoj Kumar
author_sort Mahur, Mamta
collection PubMed
description BACKGROUND: Accurate assessment of surface and build-up doses has a key role in radiotherapy, especially for the superficial lesions with uncertainties involved while performing measurements in the build-up region. OBJECTIVE: This study aimed to assess surface and build-up doses for 6 MV photon beam from linear accelerator using parallel plate ionization chamber, EBT3 Gafchromic films, and PRIMO Monte Carlo (MC) simulation code. MATERIAL AND METHODS: In this experimental study, parallel plate chamber (PPC05) and EBT3 Gafchromic films were used to measure doses in a build-up region for 6 MV beam from the linear accelerator for different field sizes at various depths ranging from 0 to 2 cm from the surface with 100 cm source to surface distance (SSD) in a solid water phantom. Measured results were compared with Monte Carlo simulated results using PENELOPE-based PRIMO simulation code for the same setup conditions. Effect of gantry angle incidence and SSD were also analyzed for depth doses at the surface and build-up regions using PPC05 ion chamber and EBT3 Gafchromic films. RESULTS: Doses measured at the surface were 14.78%, 19.87%, 25.83%, and 31.54% for field sizes of 5×5, 10×10, 15×15, and 20×20 cm(2), respectively for a 6 MV photon beam with a parallel plate chamber and 14.20%, 19.14%, 25.149%, and 30.90%, respectively for EBT3 Gafchromic films. Both measurement sets were in good agreement with corresponding simulated results from the PRIMO MC simulation code; doses increase with the increase in field sizes. CONCLUSION: Good agreement was observed between the measured depth doses using parallel plate ionization chamber, EBT3 Gafchromic films, and the simulated depth doses using PRIMO Monte Carlo simulation code.
format Online
Article
Text
id pubmed-9589075
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Shiraz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-95890752022-10-28 Assessment of Surface and Build-up Doses for a 6 MV Photon Beam using Parallel Plate Chamber, EBT3 Gafchromic Films, and PRIMO Monte Carlo Simulation Code Mahur, Mamta Singh, Munendra Gurjar, Om Prakash Semwal, Manoj Kumar J Biomed Phys Eng Original Article BACKGROUND: Accurate assessment of surface and build-up doses has a key role in radiotherapy, especially for the superficial lesions with uncertainties involved while performing measurements in the build-up region. OBJECTIVE: This study aimed to assess surface and build-up doses for 6 MV photon beam from linear accelerator using parallel plate ionization chamber, EBT3 Gafchromic films, and PRIMO Monte Carlo (MC) simulation code. MATERIAL AND METHODS: In this experimental study, parallel plate chamber (PPC05) and EBT3 Gafchromic films were used to measure doses in a build-up region for 6 MV beam from the linear accelerator for different field sizes at various depths ranging from 0 to 2 cm from the surface with 100 cm source to surface distance (SSD) in a solid water phantom. Measured results were compared with Monte Carlo simulated results using PENELOPE-based PRIMO simulation code for the same setup conditions. Effect of gantry angle incidence and SSD were also analyzed for depth doses at the surface and build-up regions using PPC05 ion chamber and EBT3 Gafchromic films. RESULTS: Doses measured at the surface were 14.78%, 19.87%, 25.83%, and 31.54% for field sizes of 5×5, 10×10, 15×15, and 20×20 cm(2), respectively for a 6 MV photon beam with a parallel plate chamber and 14.20%, 19.14%, 25.149%, and 30.90%, respectively for EBT3 Gafchromic films. Both measurement sets were in good agreement with corresponding simulated results from the PRIMO MC simulation code; doses increase with the increase in field sizes. CONCLUSION: Good agreement was observed between the measured depth doses using parallel plate ionization chamber, EBT3 Gafchromic films, and the simulated depth doses using PRIMO Monte Carlo simulation code. Shiraz University of Medical Sciences 2022-10-01 /pmc/articles/PMC9589075/ /pubmed/36313413 http://dx.doi.org/10.31661/jbpe.v0i0.2101-1274 Text en Copyright: © Journal of Biomedical Physics and Engineering https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 Unported License, ( http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Mahur, Mamta
Singh, Munendra
Gurjar, Om Prakash
Semwal, Manoj Kumar
Assessment of Surface and Build-up Doses for a 6 MV Photon Beam using Parallel Plate Chamber, EBT3 Gafchromic Films, and PRIMO Monte Carlo Simulation Code
title Assessment of Surface and Build-up Doses for a 6 MV Photon Beam using Parallel Plate Chamber, EBT3 Gafchromic Films, and PRIMO Monte Carlo Simulation Code
title_full Assessment of Surface and Build-up Doses for a 6 MV Photon Beam using Parallel Plate Chamber, EBT3 Gafchromic Films, and PRIMO Monte Carlo Simulation Code
title_fullStr Assessment of Surface and Build-up Doses for a 6 MV Photon Beam using Parallel Plate Chamber, EBT3 Gafchromic Films, and PRIMO Monte Carlo Simulation Code
title_full_unstemmed Assessment of Surface and Build-up Doses for a 6 MV Photon Beam using Parallel Plate Chamber, EBT3 Gafchromic Films, and PRIMO Monte Carlo Simulation Code
title_short Assessment of Surface and Build-up Doses for a 6 MV Photon Beam using Parallel Plate Chamber, EBT3 Gafchromic Films, and PRIMO Monte Carlo Simulation Code
title_sort assessment of surface and build-up doses for a 6 mv photon beam using parallel plate chamber, ebt3 gafchromic films, and primo monte carlo simulation code
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9589075/
https://www.ncbi.nlm.nih.gov/pubmed/36313413
http://dx.doi.org/10.31661/jbpe.v0i0.2101-1274
work_keys_str_mv AT mahurmamta assessmentofsurfaceandbuildupdosesfora6mvphotonbeamusingparallelplatechamberebt3gafchromicfilmsandprimomontecarlosimulationcode
AT singhmunendra assessmentofsurfaceandbuildupdosesfora6mvphotonbeamusingparallelplatechamberebt3gafchromicfilmsandprimomontecarlosimulationcode
AT gurjaromprakash assessmentofsurfaceandbuildupdosesfora6mvphotonbeamusingparallelplatechamberebt3gafchromicfilmsandprimomontecarlosimulationcode
AT semwalmanojkumar assessmentofsurfaceandbuildupdosesfora6mvphotonbeamusingparallelplatechamberebt3gafchromicfilmsandprimomontecarlosimulationcode