Cargando…
Prediction of Preterm Birth with Serial Measurements of Ultrasound Markers
To compare the ability of cervical length (CL), anterior cervical angle (ACA), and cervical consistency index (CCI) to predict premature birth. Methods. This prospective study involved 85 pregnant women who gave birth prematurely and a control group of 31 pregnant women who gave birth at term. The s...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medical University Publishing House Craiova
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9590368/ https://www.ncbi.nlm.nih.gov/pubmed/36320871 http://dx.doi.org/10.12865/CHSJ.48.02.04 |
_version_ | 1784814497939062784 |
---|---|
author | CAMEN, IOANA VICTORIA MANOLEA, MARIA MAGDALENA VRABIE, SIDONIA CATALINA SANDULESCU, MARIA SIDONIA SERBANESCU, MIRCEA SEBASTIAN BOLDEANU, MIHAIL VIRGIL NOVAC, LILIANA ISTRATE-OFITERU, ANCA MARIA NEAMTU, SIMONA DANIELA DIJMARESCU, ANDA LORENA |
author_facet | CAMEN, IOANA VICTORIA MANOLEA, MARIA MAGDALENA VRABIE, SIDONIA CATALINA SANDULESCU, MARIA SIDONIA SERBANESCU, MIRCEA SEBASTIAN BOLDEANU, MIHAIL VIRGIL NOVAC, LILIANA ISTRATE-OFITERU, ANCA MARIA NEAMTU, SIMONA DANIELA DIJMARESCU, ANDA LORENA |
author_sort | CAMEN, IOANA VICTORIA |
collection | PubMed |
description | To compare the ability of cervical length (CL), anterior cervical angle (ACA), and cervical consistency index (CCI) to predict premature birth. Methods. This prospective study involved 85 pregnant women who gave birth prematurely and a control group of 31 pregnant women who gave birth at term. The study was performed in the Obstetrics and Gynecology Clinic of the Municipal Clinical Hospital Filanthropia Craiova between January 1, 2019, and January 1, 2022. Cases were examined using transvaginal ultrasonography (TVU) in the second and third trimesters of pregnancy, and cervical length (CL), Anterior Cervical Angle (ACA), and Cervical Consistency Index (CCI) were measured. Results. The mean value from the three measurements at all three parameters was statistically significant with preterm birth (p<0.05). Cervical length <25mm, was highly significant in the prediction of preterm labor with a sensitivity of 99%, specificity of 61%, positive predictive value (PPV) of 78%, negative predictive value (NPV) of 97 %, and a positive likelihood ratio (LR+) of 2.54 and negative likelihood ratio (LR-) of 0.02. CCI also remains, despite low specificity and PPV values, a potential predictive parameter in the prediction of preterm birth, with a sensitivity of 73%, NPV of 92% and a LR+of 1.32 and LR- of 0.6 also correlated with CL, CCI being more difficult to interpret as an independent predictive parameter. Conclusions. CL remains the standard parameter for predicting the preterm birth, but in combination with other parameters, the prediction rate can increase significantly. |
format | Online Article Text |
id | pubmed-9590368 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Medical University Publishing House Craiova |
record_format | MEDLINE/PubMed |
spelling | pubmed-95903682022-10-31 Prediction of Preterm Birth with Serial Measurements of Ultrasound Markers CAMEN, IOANA VICTORIA MANOLEA, MARIA MAGDALENA VRABIE, SIDONIA CATALINA SANDULESCU, MARIA SIDONIA SERBANESCU, MIRCEA SEBASTIAN BOLDEANU, MIHAIL VIRGIL NOVAC, LILIANA ISTRATE-OFITERU, ANCA MARIA NEAMTU, SIMONA DANIELA DIJMARESCU, ANDA LORENA Curr Health Sci J Original Paper To compare the ability of cervical length (CL), anterior cervical angle (ACA), and cervical consistency index (CCI) to predict premature birth. Methods. This prospective study involved 85 pregnant women who gave birth prematurely and a control group of 31 pregnant women who gave birth at term. The study was performed in the Obstetrics and Gynecology Clinic of the Municipal Clinical Hospital Filanthropia Craiova between January 1, 2019, and January 1, 2022. Cases were examined using transvaginal ultrasonography (TVU) in the second and third trimesters of pregnancy, and cervical length (CL), Anterior Cervical Angle (ACA), and Cervical Consistency Index (CCI) were measured. Results. The mean value from the three measurements at all three parameters was statistically significant with preterm birth (p<0.05). Cervical length <25mm, was highly significant in the prediction of preterm labor with a sensitivity of 99%, specificity of 61%, positive predictive value (PPV) of 78%, negative predictive value (NPV) of 97 %, and a positive likelihood ratio (LR+) of 2.54 and negative likelihood ratio (LR-) of 0.02. CCI also remains, despite low specificity and PPV values, a potential predictive parameter in the prediction of preterm birth, with a sensitivity of 73%, NPV of 92% and a LR+of 1.32 and LR- of 0.6 also correlated with CL, CCI being more difficult to interpret as an independent predictive parameter. Conclusions. CL remains the standard parameter for predicting the preterm birth, but in combination with other parameters, the prediction rate can increase significantly. Medical University Publishing House Craiova 2022 2022-06-30 /pmc/articles/PMC9590368/ /pubmed/36320871 http://dx.doi.org/10.12865/CHSJ.48.02.04 Text en Copyright © 2014, Medical University Publishing House Craiova https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open-access article distributed under the terms of a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International Public License, which permits unrestricted use, adaptation, distribution and reproduction in any medium, non-commercially, provided the new creations are licensed under identical terms as the original work and the original work is properly cited. |
spellingShingle | Original Paper CAMEN, IOANA VICTORIA MANOLEA, MARIA MAGDALENA VRABIE, SIDONIA CATALINA SANDULESCU, MARIA SIDONIA SERBANESCU, MIRCEA SEBASTIAN BOLDEANU, MIHAIL VIRGIL NOVAC, LILIANA ISTRATE-OFITERU, ANCA MARIA NEAMTU, SIMONA DANIELA DIJMARESCU, ANDA LORENA Prediction of Preterm Birth with Serial Measurements of Ultrasound Markers |
title | Prediction of Preterm Birth with Serial Measurements of Ultrasound Markers |
title_full | Prediction of Preterm Birth with Serial Measurements of Ultrasound Markers |
title_fullStr | Prediction of Preterm Birth with Serial Measurements of Ultrasound Markers |
title_full_unstemmed | Prediction of Preterm Birth with Serial Measurements of Ultrasound Markers |
title_short | Prediction of Preterm Birth with Serial Measurements of Ultrasound Markers |
title_sort | prediction of preterm birth with serial measurements of ultrasound markers |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9590368/ https://www.ncbi.nlm.nih.gov/pubmed/36320871 http://dx.doi.org/10.12865/CHSJ.48.02.04 |
work_keys_str_mv | AT camenioanavictoria predictionofpretermbirthwithserialmeasurementsofultrasoundmarkers AT manoleamariamagdalena predictionofpretermbirthwithserialmeasurementsofultrasoundmarkers AT vrabiesidoniacatalina predictionofpretermbirthwithserialmeasurementsofultrasoundmarkers AT sandulescumariasidonia predictionofpretermbirthwithserialmeasurementsofultrasoundmarkers AT serbanescumirceasebastian predictionofpretermbirthwithserialmeasurementsofultrasoundmarkers AT boldeanumihailvirgil predictionofpretermbirthwithserialmeasurementsofultrasoundmarkers AT novacliliana predictionofpretermbirthwithserialmeasurementsofultrasoundmarkers AT istrateofiteruancamaria predictionofpretermbirthwithserialmeasurementsofultrasoundmarkers AT neamtusimonadaniela predictionofpretermbirthwithserialmeasurementsofultrasoundmarkers AT dijmarescuandalorena predictionofpretermbirthwithserialmeasurementsofultrasoundmarkers |