Cargando…
Hybrid split-arc partial-field volumetric modulated arc therapy: an improved beam arrangement for linear accelerator-based hippocampal-avoidance whole brain radiation therapy
BACKGROUND: This technical note aims to verify the hippocampus and adjacent organs at risk (OARs) sparing ability of an improved beam arrangement, namely hybrid split-arc partial-field volumetric modulated arc therapy (VMAT) (Hsapf-VMAT) during whole brain radiation therapy (WBRT). MATERIALS AND MET...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Via Medica
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9591038/ https://www.ncbi.nlm.nih.gov/pubmed/36299387 http://dx.doi.org/10.5603/RPOR.a2022.0022 |
_version_ | 1784814623892963328 |
---|---|
author | Yuen, Adams Hei Long Wu, Po Man Li, Alex Kai Leung Mak, Philip Chung Yin |
author_facet | Yuen, Adams Hei Long Wu, Po Man Li, Alex Kai Leung Mak, Philip Chung Yin |
author_sort | Yuen, Adams Hei Long |
collection | PubMed |
description | BACKGROUND: This technical note aims to verify the hippocampus and adjacent organs at risk (OARs) sparing ability of an improved beam arrangement, namely hybrid split-arc partial-field volumetric modulated arc therapy (VMAT) (Hsapf-VMAT) during whole brain radiation therapy (WBRT). MATERIALS AND METHODS: Computed tomography simulation images of 22 patients with brain metastases were retrieved in this retrospective planning study. The hippocampus was manually delineated according to the criterion of RTOG 0933. Plans delivering 30 Gy in 10 fractions were generated for each patient using split-arc partial-field VMAT (sapf-VMAT) and Hsapf-VMAT. The sapf-VMAT plans consisted of 4 arc fields of 179.9° each with reduced field size. The Hsapf-VMAT consisted of 4 arc fields similar to sapf-VMAT in addition to 2 lateral opposing static fields. Statistical comparisons between treatment plans of both techniques were performed using the paired t-test at 5% level significance. RESULTS: The results demonstrated that Hsapf-VMAT can achieve superior dose sparing in hippocampus which is comparable to sapf-VMAT (p > 0.05). In both eyes, Hsapf-VMAT had significantly lower D(mean) and D(max) compared to sapf-VMAT (p < 0.005). Decrease in D(max) of both lenses using Hsapf-VMAT (p < 0.005) were statistically significant when compared to sapf-VMAT. Hsapf-VMAT demonstrated significant reduction of D(mean) and D(median) to the optic nerves (p < 0.05). Whole brain planning target volume (PTV) coverage was not compromised in both techniques. CONCLUSION: The present study adopts a hybrid technique, namely Hsapf-VMAT, for hippocampal sparing WBRT. Hsapf-VMAT can achieve promising dose reduction to the hippocampus, both eyes and lenses. Therefore, Hsapf-VMAT can be considered an improved version of sapf-VMAT. |
format | Online Article Text |
id | pubmed-9591038 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Via Medica |
record_format | MEDLINE/PubMed |
spelling | pubmed-95910382022-10-25 Hybrid split-arc partial-field volumetric modulated arc therapy: an improved beam arrangement for linear accelerator-based hippocampal-avoidance whole brain radiation therapy Yuen, Adams Hei Long Wu, Po Man Li, Alex Kai Leung Mak, Philip Chung Yin Rep Pract Oncol Radiother Technical Note BACKGROUND: This technical note aims to verify the hippocampus and adjacent organs at risk (OARs) sparing ability of an improved beam arrangement, namely hybrid split-arc partial-field volumetric modulated arc therapy (VMAT) (Hsapf-VMAT) during whole brain radiation therapy (WBRT). MATERIALS AND METHODS: Computed tomography simulation images of 22 patients with brain metastases were retrieved in this retrospective planning study. The hippocampus was manually delineated according to the criterion of RTOG 0933. Plans delivering 30 Gy in 10 fractions were generated for each patient using split-arc partial-field VMAT (sapf-VMAT) and Hsapf-VMAT. The sapf-VMAT plans consisted of 4 arc fields of 179.9° each with reduced field size. The Hsapf-VMAT consisted of 4 arc fields similar to sapf-VMAT in addition to 2 lateral opposing static fields. Statistical comparisons between treatment plans of both techniques were performed using the paired t-test at 5% level significance. RESULTS: The results demonstrated that Hsapf-VMAT can achieve superior dose sparing in hippocampus which is comparable to sapf-VMAT (p > 0.05). In both eyes, Hsapf-VMAT had significantly lower D(mean) and D(max) compared to sapf-VMAT (p < 0.005). Decrease in D(max) of both lenses using Hsapf-VMAT (p < 0.005) were statistically significant when compared to sapf-VMAT. Hsapf-VMAT demonstrated significant reduction of D(mean) and D(median) to the optic nerves (p < 0.05). Whole brain planning target volume (PTV) coverage was not compromised in both techniques. CONCLUSION: The present study adopts a hybrid technique, namely Hsapf-VMAT, for hippocampal sparing WBRT. Hsapf-VMAT can achieve promising dose reduction to the hippocampus, both eyes and lenses. Therefore, Hsapf-VMAT can be considered an improved version of sapf-VMAT. Via Medica 2022-05-19 /pmc/articles/PMC9591038/ /pubmed/36299387 http://dx.doi.org/10.5603/RPOR.a2022.0022 Text en © 2022 Greater Poland Cancer Centre https://creativecommons.org/licenses/by-nc-nd/4.0/This article is available in open access under Creative Common Attribution-Non-Commercial-No Derivatives 4.0 International (CC BY-NC-ND 4.0) license, allowing to download articles and share them with others as long as they credit the authors and the publisher, but without permission to change them in any way or use them commercially |
spellingShingle | Technical Note Yuen, Adams Hei Long Wu, Po Man Li, Alex Kai Leung Mak, Philip Chung Yin Hybrid split-arc partial-field volumetric modulated arc therapy: an improved beam arrangement for linear accelerator-based hippocampal-avoidance whole brain radiation therapy |
title | Hybrid split-arc partial-field volumetric modulated arc therapy: an improved beam arrangement for linear accelerator-based hippocampal-avoidance whole brain radiation therapy |
title_full | Hybrid split-arc partial-field volumetric modulated arc therapy: an improved beam arrangement for linear accelerator-based hippocampal-avoidance whole brain radiation therapy |
title_fullStr | Hybrid split-arc partial-field volumetric modulated arc therapy: an improved beam arrangement for linear accelerator-based hippocampal-avoidance whole brain radiation therapy |
title_full_unstemmed | Hybrid split-arc partial-field volumetric modulated arc therapy: an improved beam arrangement for linear accelerator-based hippocampal-avoidance whole brain radiation therapy |
title_short | Hybrid split-arc partial-field volumetric modulated arc therapy: an improved beam arrangement for linear accelerator-based hippocampal-avoidance whole brain radiation therapy |
title_sort | hybrid split-arc partial-field volumetric modulated arc therapy: an improved beam arrangement for linear accelerator-based hippocampal-avoidance whole brain radiation therapy |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9591038/ https://www.ncbi.nlm.nih.gov/pubmed/36299387 http://dx.doi.org/10.5603/RPOR.a2022.0022 |
work_keys_str_mv | AT yuenadamsheilong hybridsplitarcpartialfieldvolumetricmodulatedarctherapyanimprovedbeamarrangementforlinearacceleratorbasedhippocampalavoidancewholebrainradiationtherapy AT wupoman hybridsplitarcpartialfieldvolumetricmodulatedarctherapyanimprovedbeamarrangementforlinearacceleratorbasedhippocampalavoidancewholebrainradiationtherapy AT lialexkaileung hybridsplitarcpartialfieldvolumetricmodulatedarctherapyanimprovedbeamarrangementforlinearacceleratorbasedhippocampalavoidancewholebrainradiationtherapy AT makphilipchungyin hybridsplitarcpartialfieldvolumetricmodulatedarctherapyanimprovedbeamarrangementforlinearacceleratorbasedhippocampalavoidancewholebrainradiationtherapy |