Cargando…

The Acoustic Change Complex Compared to Hearing Performance in Unilaterally and Bilaterally Deaf Cochlear Implant Users

Clinical measures evaluating hearing performance in cochlear implant (CI) users depend on attention and linguistic skills, which limits the evaluation of auditory perception in some patients. The acoustic change complex (ACC), a cortical auditory evoked potential to a sound change, might yield usefu...

Descripción completa

Detalles Bibliográficos
Autores principales: van Heteren, Jan A. A., Vonck, Bernard M. D., Stokroos, Robert J., Versnel, Huib, Lammers, Marc J. W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9592183/
https://www.ncbi.nlm.nih.gov/pubmed/35696186
http://dx.doi.org/10.1097/AUD.0000000000001248
_version_ 1784814866599510016
author van Heteren, Jan A. A.
Vonck, Bernard M. D.
Stokroos, Robert J.
Versnel, Huib
Lammers, Marc J. W.
author_facet van Heteren, Jan A. A.
Vonck, Bernard M. D.
Stokroos, Robert J.
Versnel, Huib
Lammers, Marc J. W.
author_sort van Heteren, Jan A. A.
collection PubMed
description Clinical measures evaluating hearing performance in cochlear implant (CI) users depend on attention and linguistic skills, which limits the evaluation of auditory perception in some patients. The acoustic change complex (ACC), a cortical auditory evoked potential to a sound change, might yield useful objective measures to assess hearing performance and could provide insight in cortical auditory processing. The aim of this study is to examine the ACC in response to frequency changes as an objective measure for hearing performance in CI users. DESIGN: Thirteen bilaterally deaf and six single-sided deaf subjects were included, all having used a unilateral CI for at least 1 year. Speech perception was tested with a consonant-vowel-consonant test (+10 dB signal-to-noise ratio) and a digits-in-noise test. Frequency discrimination thresholds were measured at two reference frequencies, using a 3-interval, 2-alternative forced-choice, adaptive staircase procedure. The two reference frequencies were selected using each participant’s frequency allocation table and were centered in the frequency band of an electrode that included 500 or 2000 Hz, corresponding to the apical electrode or the middle electrode, respectively. The ACC was evoked with pure tones of the same two reference frequencies with varying frequency increases: within the frequency band of the middle or the apical electrode (+0.25 electrode step), and steps to the center frequency of the first (+1), second (+2), and third (+3) adjacent electrodes. RESULTS: Reproducible ACCs were recorded in 17 out of 19 subjects. Most successful recordings were obtained with the largest frequency change (+3 electrode step). Larger frequency changes resulted in shorter N1 latencies and larger N1-P2 amplitudes. In both unilaterally and bilaterally deaf subjects, the N1 latency and N1-P2 amplitude of the CI ears correlated to speech perception as well as frequency discrimination, that is, short latencies and large amplitudes were indicative of better speech perception and better frequency discrimination. No significant differences in ACC latencies or amplitudes were found between the CI ears of the unilaterally and bilaterally deaf subjects, but the CI ears of the unilaterally deaf subjects showed substantially longer latencies and smaller amplitudes than their contralateral normal-hearing ears. CONCLUSIONS: The ACC latency and amplitude evoked by tone frequency changes correlate well to frequency discrimination and speech perception capabilities of CI users. For patients unable to reliably perform behavioral tasks, the ACC could be of added value in assessing hearing performance.
format Online
Article
Text
id pubmed-9592183
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-95921832022-10-27 The Acoustic Change Complex Compared to Hearing Performance in Unilaterally and Bilaterally Deaf Cochlear Implant Users van Heteren, Jan A. A. Vonck, Bernard M. D. Stokroos, Robert J. Versnel, Huib Lammers, Marc J. W. Ear Hear Research Article Clinical measures evaluating hearing performance in cochlear implant (CI) users depend on attention and linguistic skills, which limits the evaluation of auditory perception in some patients. The acoustic change complex (ACC), a cortical auditory evoked potential to a sound change, might yield useful objective measures to assess hearing performance and could provide insight in cortical auditory processing. The aim of this study is to examine the ACC in response to frequency changes as an objective measure for hearing performance in CI users. DESIGN: Thirteen bilaterally deaf and six single-sided deaf subjects were included, all having used a unilateral CI for at least 1 year. Speech perception was tested with a consonant-vowel-consonant test (+10 dB signal-to-noise ratio) and a digits-in-noise test. Frequency discrimination thresholds were measured at two reference frequencies, using a 3-interval, 2-alternative forced-choice, adaptive staircase procedure. The two reference frequencies were selected using each participant’s frequency allocation table and were centered in the frequency band of an electrode that included 500 or 2000 Hz, corresponding to the apical electrode or the middle electrode, respectively. The ACC was evoked with pure tones of the same two reference frequencies with varying frequency increases: within the frequency band of the middle or the apical electrode (+0.25 electrode step), and steps to the center frequency of the first (+1), second (+2), and third (+3) adjacent electrodes. RESULTS: Reproducible ACCs were recorded in 17 out of 19 subjects. Most successful recordings were obtained with the largest frequency change (+3 electrode step). Larger frequency changes resulted in shorter N1 latencies and larger N1-P2 amplitudes. In both unilaterally and bilaterally deaf subjects, the N1 latency and N1-P2 amplitude of the CI ears correlated to speech perception as well as frequency discrimination, that is, short latencies and large amplitudes were indicative of better speech perception and better frequency discrimination. No significant differences in ACC latencies or amplitudes were found between the CI ears of the unilaterally and bilaterally deaf subjects, but the CI ears of the unilaterally deaf subjects showed substantially longer latencies and smaller amplitudes than their contralateral normal-hearing ears. CONCLUSIONS: The ACC latency and amplitude evoked by tone frequency changes correlate well to frequency discrimination and speech perception capabilities of CI users. For patients unable to reliably perform behavioral tasks, the ACC could be of added value in assessing hearing performance. Lippincott Williams & Wilkins 2022-10-18 /pmc/articles/PMC9592183/ /pubmed/35696186 http://dx.doi.org/10.1097/AUD.0000000000001248 Text en Copyright © 2022 The Authors. Ear & Hearing is published on behalf of the American Auditory Society, by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
van Heteren, Jan A. A.
Vonck, Bernard M. D.
Stokroos, Robert J.
Versnel, Huib
Lammers, Marc J. W.
The Acoustic Change Complex Compared to Hearing Performance in Unilaterally and Bilaterally Deaf Cochlear Implant Users
title The Acoustic Change Complex Compared to Hearing Performance in Unilaterally and Bilaterally Deaf Cochlear Implant Users
title_full The Acoustic Change Complex Compared to Hearing Performance in Unilaterally and Bilaterally Deaf Cochlear Implant Users
title_fullStr The Acoustic Change Complex Compared to Hearing Performance in Unilaterally and Bilaterally Deaf Cochlear Implant Users
title_full_unstemmed The Acoustic Change Complex Compared to Hearing Performance in Unilaterally and Bilaterally Deaf Cochlear Implant Users
title_short The Acoustic Change Complex Compared to Hearing Performance in Unilaterally and Bilaterally Deaf Cochlear Implant Users
title_sort acoustic change complex compared to hearing performance in unilaterally and bilaterally deaf cochlear implant users
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9592183/
https://www.ncbi.nlm.nih.gov/pubmed/35696186
http://dx.doi.org/10.1097/AUD.0000000000001248
work_keys_str_mv AT vanheterenjanaa theacousticchangecomplexcomparedtohearingperformanceinunilaterallyandbilaterallydeafcochlearimplantusers
AT vonckbernardmd theacousticchangecomplexcomparedtohearingperformanceinunilaterallyandbilaterallydeafcochlearimplantusers
AT stokroosrobertj theacousticchangecomplexcomparedtohearingperformanceinunilaterallyandbilaterallydeafcochlearimplantusers
AT versnelhuib theacousticchangecomplexcomparedtohearingperformanceinunilaterallyandbilaterallydeafcochlearimplantusers
AT lammersmarcjw theacousticchangecomplexcomparedtohearingperformanceinunilaterallyandbilaterallydeafcochlearimplantusers
AT vanheterenjanaa acousticchangecomplexcomparedtohearingperformanceinunilaterallyandbilaterallydeafcochlearimplantusers
AT vonckbernardmd acousticchangecomplexcomparedtohearingperformanceinunilaterallyandbilaterallydeafcochlearimplantusers
AT stokroosrobertj acousticchangecomplexcomparedtohearingperformanceinunilaterallyandbilaterallydeafcochlearimplantusers
AT versnelhuib acousticchangecomplexcomparedtohearingperformanceinunilaterallyandbilaterallydeafcochlearimplantusers
AT lammersmarcjw acousticchangecomplexcomparedtohearingperformanceinunilaterallyandbilaterallydeafcochlearimplantusers