Cargando…
Safety of transesophageal echocardiography during transcatheter edge-to-edge tricuspid valve repair: A single-center experience
OBJECTIVES: We aimed to determine transesophageal echocardiography (TEE) related complications during Transcatheter edge-to-edge tricuspid valve repair (TTVR). BACKGROUND: Transesophageal echocardiography is essential to guide structural heart disease (SHD) interventions. TTVR has become an evolving...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9592690/ https://www.ncbi.nlm.nih.gov/pubmed/36304534 http://dx.doi.org/10.3389/fcvm.2022.856028 |
_version_ | 1784814983519928320 |
---|---|
author | Hellhammer, Katharina Schueler, Robert Eißmann, Mareike Schumacher, Brigitte Wolf, Alexander Bruder, Oliver Schmitz, Thomas Lambers, Moritz |
author_facet | Hellhammer, Katharina Schueler, Robert Eißmann, Mareike Schumacher, Brigitte Wolf, Alexander Bruder, Oliver Schmitz, Thomas Lambers, Moritz |
author_sort | Hellhammer, Katharina |
collection | PubMed |
description | OBJECTIVES: We aimed to determine transesophageal echocardiography (TEE) related complications during Transcatheter edge-to-edge tricuspid valve repair (TTVR). BACKGROUND: Transesophageal echocardiography is essential to guide structural heart disease (SHD) interventions. TTVR has become an evolving procedure for high-risk patients not suitable for surgery. Whether this complex procedure is associated with TEE related complications is not known so far. METHODS: We retrospectively analyzed 64 consecutive patients undergoing TTVR between 2019 and 2021 with the TriClip system (Abbott, Chicago, IL, USA) at our center. All procedures were performed under general anesthesia (GA). TEE related complications were classified as major and minor complications. RESULTS: Transesophageal echocardiography related complications were observed in two patients (3.1%) with one major complication (1.6%) and one minor complication (1.6%). In one patient perforation of the esophageal mucosa requiring red blood cell transfusion was observed, the other patient had hematemesis due to minor esophageal and gastric lesions without the need for blood transfusion. Both patients recovered during hospital stay with no persistent symptoms at discharge. CONCLUSIONS: Transesophageal echocardiography related complications during TTVR are clinically relevant occurring in 3.1% of the patients. Further investigations are needed to identify potential risk factors and patients at high risk to develop a TEE related complication in the course of TTVR. |
format | Online Article Text |
id | pubmed-9592690 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-95926902022-10-26 Safety of transesophageal echocardiography during transcatheter edge-to-edge tricuspid valve repair: A single-center experience Hellhammer, Katharina Schueler, Robert Eißmann, Mareike Schumacher, Brigitte Wolf, Alexander Bruder, Oliver Schmitz, Thomas Lambers, Moritz Front Cardiovasc Med Cardiovascular Medicine OBJECTIVES: We aimed to determine transesophageal echocardiography (TEE) related complications during Transcatheter edge-to-edge tricuspid valve repair (TTVR). BACKGROUND: Transesophageal echocardiography is essential to guide structural heart disease (SHD) interventions. TTVR has become an evolving procedure for high-risk patients not suitable for surgery. Whether this complex procedure is associated with TEE related complications is not known so far. METHODS: We retrospectively analyzed 64 consecutive patients undergoing TTVR between 2019 and 2021 with the TriClip system (Abbott, Chicago, IL, USA) at our center. All procedures were performed under general anesthesia (GA). TEE related complications were classified as major and minor complications. RESULTS: Transesophageal echocardiography related complications were observed in two patients (3.1%) with one major complication (1.6%) and one minor complication (1.6%). In one patient perforation of the esophageal mucosa requiring red blood cell transfusion was observed, the other patient had hematemesis due to minor esophageal and gastric lesions without the need for blood transfusion. Both patients recovered during hospital stay with no persistent symptoms at discharge. CONCLUSIONS: Transesophageal echocardiography related complications during TTVR are clinically relevant occurring in 3.1% of the patients. Further investigations are needed to identify potential risk factors and patients at high risk to develop a TEE related complication in the course of TTVR. Frontiers Media S.A. 2022-10-11 /pmc/articles/PMC9592690/ /pubmed/36304534 http://dx.doi.org/10.3389/fcvm.2022.856028 Text en Copyright © 2022 Hellhammer, Schueler, Eißmann, Schumacher, Wolf, Bruder, Schmitz and Lambers. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Cardiovascular Medicine Hellhammer, Katharina Schueler, Robert Eißmann, Mareike Schumacher, Brigitte Wolf, Alexander Bruder, Oliver Schmitz, Thomas Lambers, Moritz Safety of transesophageal echocardiography during transcatheter edge-to-edge tricuspid valve repair: A single-center experience |
title | Safety of transesophageal echocardiography during transcatheter edge-to-edge tricuspid valve repair: A single-center experience |
title_full | Safety of transesophageal echocardiography during transcatheter edge-to-edge tricuspid valve repair: A single-center experience |
title_fullStr | Safety of transesophageal echocardiography during transcatheter edge-to-edge tricuspid valve repair: A single-center experience |
title_full_unstemmed | Safety of transesophageal echocardiography during transcatheter edge-to-edge tricuspid valve repair: A single-center experience |
title_short | Safety of transesophageal echocardiography during transcatheter edge-to-edge tricuspid valve repair: A single-center experience |
title_sort | safety of transesophageal echocardiography during transcatheter edge-to-edge tricuspid valve repair: a single-center experience |
topic | Cardiovascular Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9592690/ https://www.ncbi.nlm.nih.gov/pubmed/36304534 http://dx.doi.org/10.3389/fcvm.2022.856028 |
work_keys_str_mv | AT hellhammerkatharina safetyoftransesophagealechocardiographyduringtranscatheteredgetoedgetricuspidvalverepairasinglecenterexperience AT schuelerrobert safetyoftransesophagealechocardiographyduringtranscatheteredgetoedgetricuspidvalverepairasinglecenterexperience AT eißmannmareike safetyoftransesophagealechocardiographyduringtranscatheteredgetoedgetricuspidvalverepairasinglecenterexperience AT schumacherbrigitte safetyoftransesophagealechocardiographyduringtranscatheteredgetoedgetricuspidvalverepairasinglecenterexperience AT wolfalexander safetyoftransesophagealechocardiographyduringtranscatheteredgetoedgetricuspidvalverepairasinglecenterexperience AT bruderoliver safetyoftransesophagealechocardiographyduringtranscatheteredgetoedgetricuspidvalverepairasinglecenterexperience AT schmitzthomas safetyoftransesophagealechocardiographyduringtranscatheteredgetoedgetricuspidvalverepairasinglecenterexperience AT lambersmoritz safetyoftransesophagealechocardiographyduringtranscatheteredgetoedgetricuspidvalverepairasinglecenterexperience |