Aerosol concentrations and size distributions during clinical dental procedures

BACKGROUND: Suspected aerosol-generating dental instruments may cause risks for operators by transmitting pathogens, such as the SARS-CoV-2 virus. The aim of our study was to measure aerosol generation in various dental procedures in clinical settings. METHODS: The study population comprised of 84 p...

Descripción completa

Detalles Bibliográficos
Autores principales: Lahdentausta, Laura, Sanmark, Enni, Lauretsalo, Saku, Korkee, Verneri, Nyman, Sini, Atanasova, Nina, Oksanen, Lotta, Zhao, Jiangyue, Hussein, Tareq, Hyvärinen, Antti, Paju, Susanna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9593181/
https://www.ncbi.nlm.nih.gov/pubmed/36303931
http://dx.doi.org/10.1016/j.heliyon.2022.e11074
Descripción
Sumario:BACKGROUND: Suspected aerosol-generating dental instruments may cause risks for operators by transmitting pathogens, such as the SARS-CoV-2 virus. The aim of our study was to measure aerosol generation in various dental procedures in clinical settings. METHODS: The study population comprised of 84 patients who underwent 253 different dental procedures measured with Optical Particle Sizer in a dental office setting. Aerosol particles from 0.3 to 10 μm in diameter were measured. Dental procedures included oral examinations (N = 52), restorative procedures with air turbine handpiece (N = 8), high-speed (N = 6) and low-speed (N = 30) handpieces, ultrasonic scaling (N = 31), periodontal treatment using hand instruments (N = 60), endodontic treatment (N = 12), intraoral radiographs (N = 24), and dental local anesthesia (N = 31). RESULTS: Air turbine handpieces significantly elevated <1 μm particle median (p = 0.013) and maximum (p = 0.016) aerosol number concentrations as well as aerosol particle mass concentrations (p = 0.046 and p = 0.006) compared to the background aerosol levels preceding the operation. Low-speed dental handpieces elevated >5 μm median (p = 0.023), maximum (p = 0.013) particle number concentrations,> 5 μm particle mass concentrations (p = 0.021) and maximum total particle mass concentrations (p = 0.022). High-speed dental handpieces elevated aerosol concentration levels compared to the levels produced during oral examination. CONCLUSIONS: Air turbine handpieces produced the highest levels of <1 μm aerosols and total particle number concentrations when compared to the other commonly used instruments. In addition, high- and low-speed dental handpieces and ultrasonic scalers elevated the aerosol concentration levels compared to the aerosol levels measured during oral examination. These aerosol-generating procedures, involving air turbine, high- and low-speed handpiece, and ultrasonic scaler, should be performed with caution. CLINICAL SIGNIFICANCE: Aerosol generating dental instruments, especially air turbine, should be used with adequate precautions (rubber dam, high-volume evacuation, FFP-respirators), because aerosols can cause a potential risk for operators and substitution of air turbine for high-speed dental handpiece in poor epidemic situations should be considered to reduce the risk of aerosol transmission.