Cargando…

Incorrectly corrected? QT interval analysis in rats and mice

QT interval, a surrogate measure for ventricular action potential duration (APD) in the surface ECG, is widely used to identify cardiac abnormalities and drug safety. In humans, cardiac APD and QT interval are prominently affected by heart rate (HR), leading to widely accepted formulas to correct th...

Descripción completa

Detalles Bibliográficos
Autores principales: Mulla, Wesam, Murninkas, Michael, Levi, Or, Etzion, Yoram
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9595597/
https://www.ncbi.nlm.nih.gov/pubmed/36304573
http://dx.doi.org/10.3389/fphys.2022.1002203
_version_ 1784815689315385344
author Mulla, Wesam
Murninkas, Michael
Levi, Or
Etzion, Yoram
author_facet Mulla, Wesam
Murninkas, Michael
Levi, Or
Etzion, Yoram
author_sort Mulla, Wesam
collection PubMed
description QT interval, a surrogate measure for ventricular action potential duration (APD) in the surface ECG, is widely used to identify cardiac abnormalities and drug safety. In humans, cardiac APD and QT interval are prominently affected by heart rate (HR), leading to widely accepted formulas to correct the QT interval for HR changes (QT corrected - QTc). While QTc is widely used in the clinic, the proper way to correct the QT interval in small mammals such as rats and mice is not clear. Over the years, empiric correction formulas were developed for rats and mice, which are widely used in the literature. Recent experimental findings obtained from pharmacological and direct pacing experiments in unanesthetized rodents show that the rate-adaptation properties are markedly different from those in humans and the use of existing QTc formulae can lead to major errors in data interpretation. In the present review, these experimental findings are summarized and discussed.
format Online
Article
Text
id pubmed-9595597
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-95955972022-10-26 Incorrectly corrected? QT interval analysis in rats and mice Mulla, Wesam Murninkas, Michael Levi, Or Etzion, Yoram Front Physiol Physiology QT interval, a surrogate measure for ventricular action potential duration (APD) in the surface ECG, is widely used to identify cardiac abnormalities and drug safety. In humans, cardiac APD and QT interval are prominently affected by heart rate (HR), leading to widely accepted formulas to correct the QT interval for HR changes (QT corrected - QTc). While QTc is widely used in the clinic, the proper way to correct the QT interval in small mammals such as rats and mice is not clear. Over the years, empiric correction formulas were developed for rats and mice, which are widely used in the literature. Recent experimental findings obtained from pharmacological and direct pacing experiments in unanesthetized rodents show that the rate-adaptation properties are markedly different from those in humans and the use of existing QTc formulae can lead to major errors in data interpretation. In the present review, these experimental findings are summarized and discussed. Frontiers Media S.A. 2022-10-11 /pmc/articles/PMC9595597/ /pubmed/36304573 http://dx.doi.org/10.3389/fphys.2022.1002203 Text en Copyright © 2022 Mulla, Murninkas, Levi and Etzion. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Mulla, Wesam
Murninkas, Michael
Levi, Or
Etzion, Yoram
Incorrectly corrected? QT interval analysis in rats and mice
title Incorrectly corrected? QT interval analysis in rats and mice
title_full Incorrectly corrected? QT interval analysis in rats and mice
title_fullStr Incorrectly corrected? QT interval analysis in rats and mice
title_full_unstemmed Incorrectly corrected? QT interval analysis in rats and mice
title_short Incorrectly corrected? QT interval analysis in rats and mice
title_sort incorrectly corrected? qt interval analysis in rats and mice
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9595597/
https://www.ncbi.nlm.nih.gov/pubmed/36304573
http://dx.doi.org/10.3389/fphys.2022.1002203
work_keys_str_mv AT mullawesam incorrectlycorrectedqtintervalanalysisinratsandmice
AT murninkasmichael incorrectlycorrectedqtintervalanalysisinratsandmice
AT levior incorrectlycorrectedqtintervalanalysisinratsandmice
AT etzionyoram incorrectlycorrectedqtintervalanalysisinratsandmice