Cargando…
Regular and irregular astigmatism of bullous keratopathy using Fourier harmonic analysis with anterior segment optical coherence tomography
Bullous keratopathy (BK) is known to present with corneal edema and Descemet's folds, which can cause corneal astigmatism. However, no report quantitatively evaluated BK astigmatism by separating it into regular and irregular astigmatism. This study investigated the regular and irregular astigm...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9596404/ https://www.ncbi.nlm.nih.gov/pubmed/36284222 http://dx.doi.org/10.1038/s41598-022-22144-w |
_version_ | 1784815863084351488 |
---|---|
author | Chen, Lily Wei Ono, Takashi Hashimoto, Yumi Tsuneya, Miki Abe, Yuito Omoto, Takashi Taketani, Yukako Toyono, Tetsuya Aihara, Makoto Miyai, Takashi |
author_facet | Chen, Lily Wei Ono, Takashi Hashimoto, Yumi Tsuneya, Miki Abe, Yuito Omoto, Takashi Taketani, Yukako Toyono, Tetsuya Aihara, Makoto Miyai, Takashi |
author_sort | Chen, Lily Wei |
collection | PubMed |
description | Bullous keratopathy (BK) is known to present with corneal edema and Descemet's folds, which can cause corneal astigmatism. However, no report quantitatively evaluated BK astigmatism by separating it into regular and irregular astigmatism. This study investigated the regular and irregular astigmatism of the anterior and posterior corneal surface with Fourier harmonic analysis and anterior segment optical coherence tomography. Preoperative data from 43 eyes of 41 BK patients who received corneal endothelial transplantation were compared with the data from 43 eyes of 43 subjects without corneal disease. Anterior and posterior cylinder power, central corneal thickness (CCT) and thinnest corneal thickness were significantly greater in BK. With Fourier harmonic analysis, BK eyes were found to have significantly larger anterior and posterior regular astigmatism, asymmetry component and higher-order irregularity. Asymmetry component and higher-order irregularity that accounted for the posterior irregular astigmatism increased as CCT increased in BK. Higher-order irregularity in the posterior cornea also positively correlated with worsening best corrected visual acuity. Subgroup analysis found significant correlations between CCT and posterior higher-order irregularity for intraocular surgery and laser iridotomy, but not Fuchs endothelial corneal dystrophy. This study has significance in that it revealed the characteristics of the corneal posterior irregular astigmatism of BK. |
format | Online Article Text |
id | pubmed-9596404 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-95964042022-10-27 Regular and irregular astigmatism of bullous keratopathy using Fourier harmonic analysis with anterior segment optical coherence tomography Chen, Lily Wei Ono, Takashi Hashimoto, Yumi Tsuneya, Miki Abe, Yuito Omoto, Takashi Taketani, Yukako Toyono, Tetsuya Aihara, Makoto Miyai, Takashi Sci Rep Article Bullous keratopathy (BK) is known to present with corneal edema and Descemet's folds, which can cause corneal astigmatism. However, no report quantitatively evaluated BK astigmatism by separating it into regular and irregular astigmatism. This study investigated the regular and irregular astigmatism of the anterior and posterior corneal surface with Fourier harmonic analysis and anterior segment optical coherence tomography. Preoperative data from 43 eyes of 41 BK patients who received corneal endothelial transplantation were compared with the data from 43 eyes of 43 subjects without corneal disease. Anterior and posterior cylinder power, central corneal thickness (CCT) and thinnest corneal thickness were significantly greater in BK. With Fourier harmonic analysis, BK eyes were found to have significantly larger anterior and posterior regular astigmatism, asymmetry component and higher-order irregularity. Asymmetry component and higher-order irregularity that accounted for the posterior irregular astigmatism increased as CCT increased in BK. Higher-order irregularity in the posterior cornea also positively correlated with worsening best corrected visual acuity. Subgroup analysis found significant correlations between CCT and posterior higher-order irregularity for intraocular surgery and laser iridotomy, but not Fuchs endothelial corneal dystrophy. This study has significance in that it revealed the characteristics of the corneal posterior irregular astigmatism of BK. Nature Publishing Group UK 2022-10-25 /pmc/articles/PMC9596404/ /pubmed/36284222 http://dx.doi.org/10.1038/s41598-022-22144-w Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Chen, Lily Wei Ono, Takashi Hashimoto, Yumi Tsuneya, Miki Abe, Yuito Omoto, Takashi Taketani, Yukako Toyono, Tetsuya Aihara, Makoto Miyai, Takashi Regular and irregular astigmatism of bullous keratopathy using Fourier harmonic analysis with anterior segment optical coherence tomography |
title | Regular and irregular astigmatism of bullous keratopathy using Fourier harmonic analysis with anterior segment optical coherence tomography |
title_full | Regular and irregular astigmatism of bullous keratopathy using Fourier harmonic analysis with anterior segment optical coherence tomography |
title_fullStr | Regular and irregular astigmatism of bullous keratopathy using Fourier harmonic analysis with anterior segment optical coherence tomography |
title_full_unstemmed | Regular and irregular astigmatism of bullous keratopathy using Fourier harmonic analysis with anterior segment optical coherence tomography |
title_short | Regular and irregular astigmatism of bullous keratopathy using Fourier harmonic analysis with anterior segment optical coherence tomography |
title_sort | regular and irregular astigmatism of bullous keratopathy using fourier harmonic analysis with anterior segment optical coherence tomography |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9596404/ https://www.ncbi.nlm.nih.gov/pubmed/36284222 http://dx.doi.org/10.1038/s41598-022-22144-w |
work_keys_str_mv | AT chenlilywei regularandirregularastigmatismofbullouskeratopathyusingfourierharmonicanalysiswithanteriorsegmentopticalcoherencetomography AT onotakashi regularandirregularastigmatismofbullouskeratopathyusingfourierharmonicanalysiswithanteriorsegmentopticalcoherencetomography AT hashimotoyumi regularandirregularastigmatismofbullouskeratopathyusingfourierharmonicanalysiswithanteriorsegmentopticalcoherencetomography AT tsuneyamiki regularandirregularastigmatismofbullouskeratopathyusingfourierharmonicanalysiswithanteriorsegmentopticalcoherencetomography AT abeyuito regularandirregularastigmatismofbullouskeratopathyusingfourierharmonicanalysiswithanteriorsegmentopticalcoherencetomography AT omototakashi regularandirregularastigmatismofbullouskeratopathyusingfourierharmonicanalysiswithanteriorsegmentopticalcoherencetomography AT taketaniyukako regularandirregularastigmatismofbullouskeratopathyusingfourierharmonicanalysiswithanteriorsegmentopticalcoherencetomography AT toyonotetsuya regularandirregularastigmatismofbullouskeratopathyusingfourierharmonicanalysiswithanteriorsegmentopticalcoherencetomography AT aiharamakoto regularandirregularastigmatismofbullouskeratopathyusingfourierharmonicanalysiswithanteriorsegmentopticalcoherencetomography AT miyaitakashi regularandirregularastigmatismofbullouskeratopathyusingfourierharmonicanalysiswithanteriorsegmentopticalcoherencetomography |