Three Medial All Suture Anchors Improves Contact Force Compared to Two Hard Body Anchors in a Biomechanical Two-Tendon Rotator Cuff Tear Model

PURPOSE: To biomechanically compare a knotless double-row construct with 3 medial all-suture (3AS) anchors with a standard 2 medial hard body (2HB) anchor construct. METHODS: Twelve matched cadaveric shoulder specimens with a mean age of 57 years (range: 54-61 years) were randomized to receive a kno...

Descripción completa

Detalles Bibliográficos
Autores principales: Hoffman, Tammy R., Lamplot, Joseph D., McClish, Sarah J., Payne, Cassie, Denard, Patrick J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9596862/
https://www.ncbi.nlm.nih.gov/pubmed/36312697
http://dx.doi.org/10.1016/j.asmr.2022.05.012
_version_ 1784815962072023040
author Hoffman, Tammy R.
Lamplot, Joseph D.
McClish, Sarah J.
Payne, Cassie
Denard, Patrick J.
author_facet Hoffman, Tammy R.
Lamplot, Joseph D.
McClish, Sarah J.
Payne, Cassie
Denard, Patrick J.
author_sort Hoffman, Tammy R.
collection PubMed
description PURPOSE: To biomechanically compare a knotless double-row construct with 3 medial all-suture (3AS) anchors with a standard 2 medial hard body (2HB) anchor construct. METHODS: Twelve matched cadaveric shoulder specimens with a mean age of 57 years (range: 54-61 years) were randomized to receive a knotless double-row repair with either a 3AS or 2HB construct. In the 3AS construct, three 2.6-mm all-suture anchors were placed adjacent to the articular margin and secured laterally with two 4.75-mm knotless hard body anchors. In the 2HB construct, two 4.75-mm medial hard body anchors were placed medially, lateral fixation was identical to the 3AS construct. Creep, displacement, stiffness, and ultimate load were recorded for each sample. In addition, a SynDaver model was used to compare contact pressure between the 2 repair constructs. RESULTS: There were no differences in cyclic displacement at 1, 30, and 100 cycles (P = .616, .497, .190, respectively), cyclic stiffness (.928), ultimate load (.445), or load to failure (P = .445) between the 2 constructs. The 3AS repair construct had improved contact pressure between tendon and bone when compared with the 2HB construct at loads of 20 N, 30 N, and 40 N (P = .01, .02, and .04, respectively). CONCLUSIONS: Displacement and load to failure properties are similar between knotless constructs using either 2HB or 3AS for the medial row. However, contact force may improve with the use of 3 medial all-suture anchors. CLINICAL RELEVANCE: As all-suture anchors are smaller in size when compared with hard body anchors. For this reason, there is potential to place an additional all-suture medial anchor to improve contact force and potentially improve rotator cuff healing when compared with the use of hard body anchors.
format Online
Article
Text
id pubmed-9596862
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-95968622022-10-27 Three Medial All Suture Anchors Improves Contact Force Compared to Two Hard Body Anchors in a Biomechanical Two-Tendon Rotator Cuff Tear Model Hoffman, Tammy R. Lamplot, Joseph D. McClish, Sarah J. Payne, Cassie Denard, Patrick J. Arthrosc Sports Med Rehabil Original Article PURPOSE: To biomechanically compare a knotless double-row construct with 3 medial all-suture (3AS) anchors with a standard 2 medial hard body (2HB) anchor construct. METHODS: Twelve matched cadaveric shoulder specimens with a mean age of 57 years (range: 54-61 years) were randomized to receive a knotless double-row repair with either a 3AS or 2HB construct. In the 3AS construct, three 2.6-mm all-suture anchors were placed adjacent to the articular margin and secured laterally with two 4.75-mm knotless hard body anchors. In the 2HB construct, two 4.75-mm medial hard body anchors were placed medially, lateral fixation was identical to the 3AS construct. Creep, displacement, stiffness, and ultimate load were recorded for each sample. In addition, a SynDaver model was used to compare contact pressure between the 2 repair constructs. RESULTS: There were no differences in cyclic displacement at 1, 30, and 100 cycles (P = .616, .497, .190, respectively), cyclic stiffness (.928), ultimate load (.445), or load to failure (P = .445) between the 2 constructs. The 3AS repair construct had improved contact pressure between tendon and bone when compared with the 2HB construct at loads of 20 N, 30 N, and 40 N (P = .01, .02, and .04, respectively). CONCLUSIONS: Displacement and load to failure properties are similar between knotless constructs using either 2HB or 3AS for the medial row. However, contact force may improve with the use of 3 medial all-suture anchors. CLINICAL RELEVANCE: As all-suture anchors are smaller in size when compared with hard body anchors. For this reason, there is potential to place an additional all-suture medial anchor to improve contact force and potentially improve rotator cuff healing when compared with the use of hard body anchors. Elsevier 2022-08-05 /pmc/articles/PMC9596862/ /pubmed/36312697 http://dx.doi.org/10.1016/j.asmr.2022.05.012 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Hoffman, Tammy R.
Lamplot, Joseph D.
McClish, Sarah J.
Payne, Cassie
Denard, Patrick J.
Three Medial All Suture Anchors Improves Contact Force Compared to Two Hard Body Anchors in a Biomechanical Two-Tendon Rotator Cuff Tear Model
title Three Medial All Suture Anchors Improves Contact Force Compared to Two Hard Body Anchors in a Biomechanical Two-Tendon Rotator Cuff Tear Model
title_full Three Medial All Suture Anchors Improves Contact Force Compared to Two Hard Body Anchors in a Biomechanical Two-Tendon Rotator Cuff Tear Model
title_fullStr Three Medial All Suture Anchors Improves Contact Force Compared to Two Hard Body Anchors in a Biomechanical Two-Tendon Rotator Cuff Tear Model
title_full_unstemmed Three Medial All Suture Anchors Improves Contact Force Compared to Two Hard Body Anchors in a Biomechanical Two-Tendon Rotator Cuff Tear Model
title_short Three Medial All Suture Anchors Improves Contact Force Compared to Two Hard Body Anchors in a Biomechanical Two-Tendon Rotator Cuff Tear Model
title_sort three medial all suture anchors improves contact force compared to two hard body anchors in a biomechanical two-tendon rotator cuff tear model
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9596862/
https://www.ncbi.nlm.nih.gov/pubmed/36312697
http://dx.doi.org/10.1016/j.asmr.2022.05.012
work_keys_str_mv AT hoffmantammyr threemedialallsutureanchorsimprovescontactforcecomparedtotwohardbodyanchorsinabiomechanicaltwotendonrotatorcufftearmodel
AT lamplotjosephd threemedialallsutureanchorsimprovescontactforcecomparedtotwohardbodyanchorsinabiomechanicaltwotendonrotatorcufftearmodel
AT mcclishsarahj threemedialallsutureanchorsimprovescontactforcecomparedtotwohardbodyanchorsinabiomechanicaltwotendonrotatorcufftearmodel
AT paynecassie threemedialallsutureanchorsimprovescontactforcecomparedtotwohardbodyanchorsinabiomechanicaltwotendonrotatorcufftearmodel
AT denardpatrickj threemedialallsutureanchorsimprovescontactforcecomparedtotwohardbodyanchorsinabiomechanicaltwotendonrotatorcufftearmodel