Five-Strand Hamstring Grafts are Biomechanically Comparable to Four-Strand Grafts and Offer Greater Diameter for Anterior Cruciate Ligament Reconstruction

PURPOSE: The purpose of this study was to compare the biomechanics of 4-strand and 5-strand hamstring constructs for anterior cruciate ligament grafts. METHODS: Thirty-six human cadaveric hamstring grafts were tested in 3 different conditions: (1) graft femoral fixation complex, (2) graft femoral an...

Descripción completa

Detalles Bibliográficos
Autores principales: Brzezinski, Andrzej, Nasra, Matthew, Pfaff, William, Imbergamo, Casey, Simon, Michael, Tarapore, Rae, Xavier, Jorden, Ghodbane, Salim, Gatt, Charles
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9596886/
https://www.ncbi.nlm.nih.gov/pubmed/36312720
http://dx.doi.org/10.1016/j.asmr.2022.06.020
Descripción
Sumario:PURPOSE: The purpose of this study was to compare the biomechanics of 4-strand and 5-strand hamstring constructs for anterior cruciate ligament grafts. METHODS: Thirty-six human cadaveric hamstring grafts were tested in 3 different conditions: (1) graft femoral fixation complex, (2) graft femoral and tibial fixation (GFTF) complex using a human model, and (3) GFTF complex using a porcine model. Grafts were tested on a tensile testing machine. Four-stranded grafts served as the control group, and 5-stranded grafts served as the experimental group. Cyclic elongation, ultimate load to failure, stiffness, and diameter of the grafts were analyzed. RESULTS: Average 4-strand graft diameter was 7.96 mm compared to 9.32 mm for the 5-strand graft (P = .00017). Average stiffness of grafts ≥8 mm was 105.04 N/mm compared to 85.05 N/mm for grafts <8 mm (P = .04988). There was a positive correlation between graft diameter and stiffness (13.4 N/mm per every 1 mm increase in diameter, r(2) value of 13.1%, and F-significance of 0.02778). There were no significant differences in terms of ultimate load to failure, cyclic elongation, or stiffness between the experimental groups. CONCLUSION: Five-strand hamstring grafts offer greater diameter and are biomechanically comparable to 4-strand equivalents at time 0. Grafts >8 mm offer significantly greater stiffness compared to grafts sized <8 mm. There is a weak positive correlation between graft diameter and stiffness. CLINICAL RELEVANCE: A potential drawback to hamstring grafts is their variability in size. Five-strand hamstring grafts provide increased diameter in comparison to 4-strand equivalents and might be used when quadrupled graft diameter is <8 mm.