Cargando…

Encoder-Controlled Functional Electrical Stimulator for Bilateral Wrist Activities—Design and Evaluation

Upper limb impairment following stroke is often characterized by limited voluntary control in the affected arm. In addition, significant motor coordination problems occur on the unaffected arm due to avoidance of performing bilateral symmetrical activities. Rehabilitation strategies should, therefor...

Descripción completa

Detalles Bibliográficos
Autores principales: Solomons, Cassandra D., Shanmugasundaram, Vivekanandan, Balasubramanian, Sivakumar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9598413/
https://www.ncbi.nlm.nih.gov/pubmed/36290469
http://dx.doi.org/10.3390/bioengineering9100501
_version_ 1784816327875100672
author Solomons, Cassandra D.
Shanmugasundaram, Vivekanandan
Balasubramanian, Sivakumar
author_facet Solomons, Cassandra D.
Shanmugasundaram, Vivekanandan
Balasubramanian, Sivakumar
author_sort Solomons, Cassandra D.
collection PubMed
description Upper limb impairment following stroke is often characterized by limited voluntary control in the affected arm. In addition, significant motor coordination problems occur on the unaffected arm due to avoidance of performing bilateral symmetrical activities. Rehabilitation strategies should, therefore, not only aim at improving voluntary control on the affected arm, but also contribute to synchronizing activity from both upper limbs. The encoder-controlled functional electrical stimulator, described in this paper, implements precise contralateral control of wrist flexion and extension with electrical stimulation. The stimulator is calibrated for each individual to obtain a table of stimulation parameters versus wrist angle. This table is used to set stimulation parameters dynamically, based on the difference in wrist angle between the set and stimulated side, which is continuously monitored. This allows the wrist on the stimulated side to follow flexion and extension patterns on the set side, thereby mirroring wrist movements of the normal side. This device also gives real-time graphical feedback on how the stimulated wrist is performing in comparison to the normal side. A study was performed on 25 normal volunteers to determine how closely wrist movements on the set side were being followed on the stimulated side. Graphical results show that there were minor differences, which were quantified by considering the peak angles of flexion and extension on the set and stimulated side for each participant. The mean difference in peak flexion and extension range of movement was 2.3 degrees and 1.9 degrees, respectively, with a mean time lag of 1 s between the set and the stimulated angle graphs.
format Online
Article
Text
id pubmed-9598413
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-95984132022-10-27 Encoder-Controlled Functional Electrical Stimulator for Bilateral Wrist Activities—Design and Evaluation Solomons, Cassandra D. Shanmugasundaram, Vivekanandan Balasubramanian, Sivakumar Bioengineering (Basel) Article Upper limb impairment following stroke is often characterized by limited voluntary control in the affected arm. In addition, significant motor coordination problems occur on the unaffected arm due to avoidance of performing bilateral symmetrical activities. Rehabilitation strategies should, therefore, not only aim at improving voluntary control on the affected arm, but also contribute to synchronizing activity from both upper limbs. The encoder-controlled functional electrical stimulator, described in this paper, implements precise contralateral control of wrist flexion and extension with electrical stimulation. The stimulator is calibrated for each individual to obtain a table of stimulation parameters versus wrist angle. This table is used to set stimulation parameters dynamically, based on the difference in wrist angle between the set and stimulated side, which is continuously monitored. This allows the wrist on the stimulated side to follow flexion and extension patterns on the set side, thereby mirroring wrist movements of the normal side. This device also gives real-time graphical feedback on how the stimulated wrist is performing in comparison to the normal side. A study was performed on 25 normal volunteers to determine how closely wrist movements on the set side were being followed on the stimulated side. Graphical results show that there were minor differences, which were quantified by considering the peak angles of flexion and extension on the set and stimulated side for each participant. The mean difference in peak flexion and extension range of movement was 2.3 degrees and 1.9 degrees, respectively, with a mean time lag of 1 s between the set and the stimulated angle graphs. MDPI 2022-09-24 /pmc/articles/PMC9598413/ /pubmed/36290469 http://dx.doi.org/10.3390/bioengineering9100501 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Solomons, Cassandra D.
Shanmugasundaram, Vivekanandan
Balasubramanian, Sivakumar
Encoder-Controlled Functional Electrical Stimulator for Bilateral Wrist Activities—Design and Evaluation
title Encoder-Controlled Functional Electrical Stimulator for Bilateral Wrist Activities—Design and Evaluation
title_full Encoder-Controlled Functional Electrical Stimulator for Bilateral Wrist Activities—Design and Evaluation
title_fullStr Encoder-Controlled Functional Electrical Stimulator for Bilateral Wrist Activities—Design and Evaluation
title_full_unstemmed Encoder-Controlled Functional Electrical Stimulator for Bilateral Wrist Activities—Design and Evaluation
title_short Encoder-Controlled Functional Electrical Stimulator for Bilateral Wrist Activities—Design and Evaluation
title_sort encoder-controlled functional electrical stimulator for bilateral wrist activities—design and evaluation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9598413/
https://www.ncbi.nlm.nih.gov/pubmed/36290469
http://dx.doi.org/10.3390/bioengineering9100501
work_keys_str_mv AT solomonscassandrad encodercontrolledfunctionalelectricalstimulatorforbilateralwristactivitiesdesignandevaluation
AT shanmugasundaramvivekanandan encodercontrolledfunctionalelectricalstimulatorforbilateralwristactivitiesdesignandevaluation
AT balasubramaniansivakumar encodercontrolledfunctionalelectricalstimulatorforbilateralwristactivitiesdesignandevaluation