Cargando…

A Portable Servoregulation Controller to Automate CO(2) Removal in Artificial Lungs

Artificial lung (AL) systems provide respiratory support to patients with severe lung disease, but none can adapt to the changing respiratory needs of the patients. Precisely, none can automatically adjust carbon dioxide ([Formula: see text]) removal from the blood in response to changes in patient...

Descripción completa

Detalles Bibliográficos
Autores principales: Shaikh, Navid, Zhang, Andrew, Jenter, Jesse, Nikpreljevic, Brandon, Toomasian, John, Lynch, William, Rojas-Peña, Alvaro, Bartlett, Robert H., Potkay, Joseph A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9598878/
https://www.ncbi.nlm.nih.gov/pubmed/36290561
http://dx.doi.org/10.3390/bioengineering9100593
_version_ 1784816457077489664
author Shaikh, Navid
Zhang, Andrew
Jenter, Jesse
Nikpreljevic, Brandon
Toomasian, John
Lynch, William
Rojas-Peña, Alvaro
Bartlett, Robert H.
Potkay, Joseph A.
author_facet Shaikh, Navid
Zhang, Andrew
Jenter, Jesse
Nikpreljevic, Brandon
Toomasian, John
Lynch, William
Rojas-Peña, Alvaro
Bartlett, Robert H.
Potkay, Joseph A.
author_sort Shaikh, Navid
collection PubMed
description Artificial lung (AL) systems provide respiratory support to patients with severe lung disease, but none can adapt to the changing respiratory needs of the patients. Precisely, none can automatically adjust carbon dioxide ([Formula: see text]) removal from the blood in response to changes in patient activity or disease status. Because of this, all current systems limit patient comfort, activity level, and rehabilitation. A portable servoregulation controller that automatically modulates [Formula: see text] removal in ALs to meet the real-time metabolic demands of the patient is described. The controller is based on a proportional-integral-derivative (PID) based closed-loop feedback control system that modulates sweep gas (air) flow through the AL to maintain a target exhaust gas [Formula: see text] partial pressure (target [Formula: see text] or [Formula: see text]). The presented work advances previous research by (1) using gas-side sensing that avoids complications and clotting associated with blood-based sensors, (2) incorporating all components into a portable, battery-powered package, and (3) integrating smart moisture removal from the AL to enable long term operation. The performance of the controller was tested in vitro for ∼12 h with anti-coagulated bovine blood and 5 days with distilled water. In tests with blood, the sweep gas flow was automatically adjusted by the controller rapidly (<2 min) meeting the specified tEG [Formula: see text] level when confronted with changes in inlet blood partial pressure of [Formula: see text] (p [Formula: see text]) levels at various AL blood flows. Overall, the [Formula: see text] removal from the AL showed a strong correlation with blood flow rate and blood p [Formula: see text] levels. The controller successfully operated continuously for 5 days when tested with water. This study demonstrates an important step toward ambulatory AL systems that automatically modulate [Formula: see text] removal as required by lung disease patients, thereby allowing for physiotherapy, comfort, and activity.
format Online
Article
Text
id pubmed-9598878
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-95988782022-10-27 A Portable Servoregulation Controller to Automate CO(2) Removal in Artificial Lungs Shaikh, Navid Zhang, Andrew Jenter, Jesse Nikpreljevic, Brandon Toomasian, John Lynch, William Rojas-Peña, Alvaro Bartlett, Robert H. Potkay, Joseph A. Bioengineering (Basel) Article Artificial lung (AL) systems provide respiratory support to patients with severe lung disease, but none can adapt to the changing respiratory needs of the patients. Precisely, none can automatically adjust carbon dioxide ([Formula: see text]) removal from the blood in response to changes in patient activity or disease status. Because of this, all current systems limit patient comfort, activity level, and rehabilitation. A portable servoregulation controller that automatically modulates [Formula: see text] removal in ALs to meet the real-time metabolic demands of the patient is described. The controller is based on a proportional-integral-derivative (PID) based closed-loop feedback control system that modulates sweep gas (air) flow through the AL to maintain a target exhaust gas [Formula: see text] partial pressure (target [Formula: see text] or [Formula: see text]). The presented work advances previous research by (1) using gas-side sensing that avoids complications and clotting associated with blood-based sensors, (2) incorporating all components into a portable, battery-powered package, and (3) integrating smart moisture removal from the AL to enable long term operation. The performance of the controller was tested in vitro for ∼12 h with anti-coagulated bovine blood and 5 days with distilled water. In tests with blood, the sweep gas flow was automatically adjusted by the controller rapidly (<2 min) meeting the specified tEG [Formula: see text] level when confronted with changes in inlet blood partial pressure of [Formula: see text] (p [Formula: see text]) levels at various AL blood flows. Overall, the [Formula: see text] removal from the AL showed a strong correlation with blood flow rate and blood p [Formula: see text] levels. The controller successfully operated continuously for 5 days when tested with water. This study demonstrates an important step toward ambulatory AL systems that automatically modulate [Formula: see text] removal as required by lung disease patients, thereby allowing for physiotherapy, comfort, and activity. MDPI 2022-10-21 /pmc/articles/PMC9598878/ /pubmed/36290561 http://dx.doi.org/10.3390/bioengineering9100593 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Shaikh, Navid
Zhang, Andrew
Jenter, Jesse
Nikpreljevic, Brandon
Toomasian, John
Lynch, William
Rojas-Peña, Alvaro
Bartlett, Robert H.
Potkay, Joseph A.
A Portable Servoregulation Controller to Automate CO(2) Removal in Artificial Lungs
title A Portable Servoregulation Controller to Automate CO(2) Removal in Artificial Lungs
title_full A Portable Servoregulation Controller to Automate CO(2) Removal in Artificial Lungs
title_fullStr A Portable Servoregulation Controller to Automate CO(2) Removal in Artificial Lungs
title_full_unstemmed A Portable Servoregulation Controller to Automate CO(2) Removal in Artificial Lungs
title_short A Portable Servoregulation Controller to Automate CO(2) Removal in Artificial Lungs
title_sort portable servoregulation controller to automate co(2) removal in artificial lungs
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9598878/
https://www.ncbi.nlm.nih.gov/pubmed/36290561
http://dx.doi.org/10.3390/bioengineering9100593
work_keys_str_mv AT shaikhnavid aportableservoregulationcontrollertoautomateco2removalinartificiallungs
AT zhangandrew aportableservoregulationcontrollertoautomateco2removalinartificiallungs
AT jenterjesse aportableservoregulationcontrollertoautomateco2removalinartificiallungs
AT nikpreljevicbrandon aportableservoregulationcontrollertoautomateco2removalinartificiallungs
AT toomasianjohn aportableservoregulationcontrollertoautomateco2removalinartificiallungs
AT lynchwilliam aportableservoregulationcontrollertoautomateco2removalinartificiallungs
AT rojaspenaalvaro aportableservoregulationcontrollertoautomateco2removalinartificiallungs
AT bartlettroberth aportableservoregulationcontrollertoautomateco2removalinartificiallungs
AT potkayjosepha aportableservoregulationcontrollertoautomateco2removalinartificiallungs
AT shaikhnavid portableservoregulationcontrollertoautomateco2removalinartificiallungs
AT zhangandrew portableservoregulationcontrollertoautomateco2removalinartificiallungs
AT jenterjesse portableservoregulationcontrollertoautomateco2removalinartificiallungs
AT nikpreljevicbrandon portableservoregulationcontrollertoautomateco2removalinartificiallungs
AT toomasianjohn portableservoregulationcontrollertoautomateco2removalinartificiallungs
AT lynchwilliam portableservoregulationcontrollertoautomateco2removalinartificiallungs
AT rojaspenaalvaro portableservoregulationcontrollertoautomateco2removalinartificiallungs
AT bartlettroberth portableservoregulationcontrollertoautomateco2removalinartificiallungs
AT potkayjosepha portableservoregulationcontrollertoautomateco2removalinartificiallungs