A Core–Shell Au@TiO(2) and Multi-Walled Carbon Nanotube-Based Sensor for the Electroanalytical Determination of H(2)O(2) in Human Blood Serum and Saliva

A hydrogen peroxide (H(2)O(2)) sensor was developed based on core–shell gold@titanium dioxide nanoparticles and multi-walled carbon nanotubes modified glassy carbon electrode (Au@TiO(2)/MWCNTs/GCE). Core–shell Au@TiO(2) material was prepared and characterized using a scanning electron microscopy and...

Descripción completa

Detalles Bibliográficos
Autores principales: Saeed, Ayman Ali, Abbas, Mohammed Nooredeen, El-Hawary, Waheed Fathi, Issa, Yousry Moustafa, Singh, Baljit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9599508/
https://www.ncbi.nlm.nih.gov/pubmed/36290916
http://dx.doi.org/10.3390/bios12100778
_version_ 1784816611544268800
author Saeed, Ayman Ali
Abbas, Mohammed Nooredeen
El-Hawary, Waheed Fathi
Issa, Yousry Moustafa
Singh, Baljit
author_facet Saeed, Ayman Ali
Abbas, Mohammed Nooredeen
El-Hawary, Waheed Fathi
Issa, Yousry Moustafa
Singh, Baljit
author_sort Saeed, Ayman Ali
collection PubMed
description A hydrogen peroxide (H(2)O(2)) sensor was developed based on core–shell gold@titanium dioxide nanoparticles and multi-walled carbon nanotubes modified glassy carbon electrode (Au@TiO(2)/MWCNTs/GCE). Core–shell Au@TiO(2) material was prepared and characterized using a scanning electron microscopy and energy dispersive X-ray analysis (SEM/EDX), transmission electron microscopy (TEM), atomic force microscopy (AFM), Raman spectroscopy, X-ray diffraction (XRD) and Zeta-potential analyzer. The proposed sensor (Au@TiO(2)/MWCNTs/GCE) was investigated electrochemically using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The analytical performance of the sensor was evaluated towards H(2)O(2) using differential pulse voltammetry (DPV). The proposed sensor exhibited excellent stability and sensitivity with a linear concentration range from 5 to 200 µM (R(2) = 0.9973) and 200 to 6000 µM (R(2) = 0.9994), and a limit of detection (LOD) of 1.4 µM achieved under physiological pH conditions. The practicality of the proposed sensor was further tested by measuring H(2)O(2) in human serum and saliva samples. The observed response and recovery results demonstrate its potential for real-world H(2)O(2) monitoring. Additionally, the proposed sensor and detection strategy can offer potential prospects in electrochemical sensors development, indicative oxidative stress monitoring, clinical diagnostics, general cancer biomarker measurements, paper bleaching, etc.
format Online
Article
Text
id pubmed-9599508
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-95995082022-10-27 A Core–Shell Au@TiO(2) and Multi-Walled Carbon Nanotube-Based Sensor for the Electroanalytical Determination of H(2)O(2) in Human Blood Serum and Saliva Saeed, Ayman Ali Abbas, Mohammed Nooredeen El-Hawary, Waheed Fathi Issa, Yousry Moustafa Singh, Baljit Biosensors (Basel) Article A hydrogen peroxide (H(2)O(2)) sensor was developed based on core–shell gold@titanium dioxide nanoparticles and multi-walled carbon nanotubes modified glassy carbon electrode (Au@TiO(2)/MWCNTs/GCE). Core–shell Au@TiO(2) material was prepared and characterized using a scanning electron microscopy and energy dispersive X-ray analysis (SEM/EDX), transmission electron microscopy (TEM), atomic force microscopy (AFM), Raman spectroscopy, X-ray diffraction (XRD) and Zeta-potential analyzer. The proposed sensor (Au@TiO(2)/MWCNTs/GCE) was investigated electrochemically using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The analytical performance of the sensor was evaluated towards H(2)O(2) using differential pulse voltammetry (DPV). The proposed sensor exhibited excellent stability and sensitivity with a linear concentration range from 5 to 200 µM (R(2) = 0.9973) and 200 to 6000 µM (R(2) = 0.9994), and a limit of detection (LOD) of 1.4 µM achieved under physiological pH conditions. The practicality of the proposed sensor was further tested by measuring H(2)O(2) in human serum and saliva samples. The observed response and recovery results demonstrate its potential for real-world H(2)O(2) monitoring. Additionally, the proposed sensor and detection strategy can offer potential prospects in electrochemical sensors development, indicative oxidative stress monitoring, clinical diagnostics, general cancer biomarker measurements, paper bleaching, etc. MDPI 2022-09-20 /pmc/articles/PMC9599508/ /pubmed/36290916 http://dx.doi.org/10.3390/bios12100778 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Saeed, Ayman Ali
Abbas, Mohammed Nooredeen
El-Hawary, Waheed Fathi
Issa, Yousry Moustafa
Singh, Baljit
A Core–Shell Au@TiO(2) and Multi-Walled Carbon Nanotube-Based Sensor for the Electroanalytical Determination of H(2)O(2) in Human Blood Serum and Saliva
title A Core–Shell Au@TiO(2) and Multi-Walled Carbon Nanotube-Based Sensor for the Electroanalytical Determination of H(2)O(2) in Human Blood Serum and Saliva
title_full A Core–Shell Au@TiO(2) and Multi-Walled Carbon Nanotube-Based Sensor for the Electroanalytical Determination of H(2)O(2) in Human Blood Serum and Saliva
title_fullStr A Core–Shell Au@TiO(2) and Multi-Walled Carbon Nanotube-Based Sensor for the Electroanalytical Determination of H(2)O(2) in Human Blood Serum and Saliva
title_full_unstemmed A Core–Shell Au@TiO(2) and Multi-Walled Carbon Nanotube-Based Sensor for the Electroanalytical Determination of H(2)O(2) in Human Blood Serum and Saliva
title_short A Core–Shell Au@TiO(2) and Multi-Walled Carbon Nanotube-Based Sensor for the Electroanalytical Determination of H(2)O(2) in Human Blood Serum and Saliva
title_sort core–shell au@tio(2) and multi-walled carbon nanotube-based sensor for the electroanalytical determination of h(2)o(2) in human blood serum and saliva
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9599508/
https://www.ncbi.nlm.nih.gov/pubmed/36290916
http://dx.doi.org/10.3390/bios12100778
work_keys_str_mv AT saeedaymanali acoreshellautio2andmultiwalledcarbonnanotubebasedsensorfortheelectroanalyticaldeterminationofh2o2inhumanbloodserumandsaliva
AT abbasmohammednooredeen acoreshellautio2andmultiwalledcarbonnanotubebasedsensorfortheelectroanalyticaldeterminationofh2o2inhumanbloodserumandsaliva
AT elhawarywaheedfathi acoreshellautio2andmultiwalledcarbonnanotubebasedsensorfortheelectroanalyticaldeterminationofh2o2inhumanbloodserumandsaliva
AT issayousrymoustafa acoreshellautio2andmultiwalledcarbonnanotubebasedsensorfortheelectroanalyticaldeterminationofh2o2inhumanbloodserumandsaliva
AT singhbaljit acoreshellautio2andmultiwalledcarbonnanotubebasedsensorfortheelectroanalyticaldeterminationofh2o2inhumanbloodserumandsaliva
AT saeedaymanali coreshellautio2andmultiwalledcarbonnanotubebasedsensorfortheelectroanalyticaldeterminationofh2o2inhumanbloodserumandsaliva
AT abbasmohammednooredeen coreshellautio2andmultiwalledcarbonnanotubebasedsensorfortheelectroanalyticaldeterminationofh2o2inhumanbloodserumandsaliva
AT elhawarywaheedfathi coreshellautio2andmultiwalledcarbonnanotubebasedsensorfortheelectroanalyticaldeterminationofh2o2inhumanbloodserumandsaliva
AT issayousrymoustafa coreshellautio2andmultiwalledcarbonnanotubebasedsensorfortheelectroanalyticaldeterminationofh2o2inhumanbloodserumandsaliva
AT singhbaljit coreshellautio2andmultiwalledcarbonnanotubebasedsensorfortheelectroanalyticaldeterminationofh2o2inhumanbloodserumandsaliva