Cargando…
Study on the Effect of Non-Symmetrical Current Distribution Controlled by Capacitor Placement in Radio-Frequency Coils for 7T MRI
In this paper, we present a study on the effects of varying the position of a single tuning capacitor in a circular loop coil as a mechanism to control and produce non-symmetric current distribution, such that could be used for magnetic resonance imaging (MRI) operating at ultra-high frequency (UHF)...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9599509/ https://www.ncbi.nlm.nih.gov/pubmed/36291004 http://dx.doi.org/10.3390/bios12100867 |
_version_ | 1784816611790684160 |
---|---|
author | Hernandez, Daniel Nam, Taewoo Jeong, Yonghwa Kim, Donghyuk Kim, Kyoung-Nam |
author_facet | Hernandez, Daniel Nam, Taewoo Jeong, Yonghwa Kim, Donghyuk Kim, Kyoung-Nam |
author_sort | Hernandez, Daniel |
collection | PubMed |
description | In this paper, we present a study on the effects of varying the position of a single tuning capacitor in a circular loop coil as a mechanism to control and produce non-symmetric current distribution, such that could be used for magnetic resonance imaging (MRI) operating at ultra-high frequency (UHF). This study aims to demonstrate that the position of the tuning capacitor of a circular loop could improve the coupling between adjacent coils, used to optimize transmission field uniformity or intensity, improve signal-to-noise ratio (SNR) or specific absorption rate (SAR). A typical loop coil used in MRI consists of symmetrically distributed capacitors along the coil; this design is able to produce uniform current distributions inside the coil. However, in UHF conditions, the magnetic flux density (|B(1)(+)|) field produced by this setup may exhibit field distortion, requiring a method of controlling the field distribution and improving the field intensity of the circular loop coil. The control mechanism investigated in this study is based on the position of the tuning capacitor in the circular coil, the capacitor position was varied from 15° to 345°, in steps of 15°. We performed electromagnetic (EM) simulations, fabricated the coils, and performed MRI experiments at 7T, with each of the coils with capacitor position from 15° to 345° to determine the effects on field intensity, coupling between adjacent coils, SAR, and applications for field uniformity optimization. For the case of free space, a coil with capacitor position at 15° showed higher field intensity compared to the reference coil; while an improved decoupling was achieved when a coil had the capacitor placed at 180° and the other coil at 90°; in a similar matter, we discuss the results for SAR, field uniformity and an application with an array coil for the spinal cord. |
format | Online Article Text |
id | pubmed-9599509 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-95995092022-10-27 Study on the Effect of Non-Symmetrical Current Distribution Controlled by Capacitor Placement in Radio-Frequency Coils for 7T MRI Hernandez, Daniel Nam, Taewoo Jeong, Yonghwa Kim, Donghyuk Kim, Kyoung-Nam Biosensors (Basel) Article In this paper, we present a study on the effects of varying the position of a single tuning capacitor in a circular loop coil as a mechanism to control and produce non-symmetric current distribution, such that could be used for magnetic resonance imaging (MRI) operating at ultra-high frequency (UHF). This study aims to demonstrate that the position of the tuning capacitor of a circular loop could improve the coupling between adjacent coils, used to optimize transmission field uniformity or intensity, improve signal-to-noise ratio (SNR) or specific absorption rate (SAR). A typical loop coil used in MRI consists of symmetrically distributed capacitors along the coil; this design is able to produce uniform current distributions inside the coil. However, in UHF conditions, the magnetic flux density (|B(1)(+)|) field produced by this setup may exhibit field distortion, requiring a method of controlling the field distribution and improving the field intensity of the circular loop coil. The control mechanism investigated in this study is based on the position of the tuning capacitor in the circular coil, the capacitor position was varied from 15° to 345°, in steps of 15°. We performed electromagnetic (EM) simulations, fabricated the coils, and performed MRI experiments at 7T, with each of the coils with capacitor position from 15° to 345° to determine the effects on field intensity, coupling between adjacent coils, SAR, and applications for field uniformity optimization. For the case of free space, a coil with capacitor position at 15° showed higher field intensity compared to the reference coil; while an improved decoupling was achieved when a coil had the capacitor placed at 180° and the other coil at 90°; in a similar matter, we discuss the results for SAR, field uniformity and an application with an array coil for the spinal cord. MDPI 2022-10-12 /pmc/articles/PMC9599509/ /pubmed/36291004 http://dx.doi.org/10.3390/bios12100867 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Hernandez, Daniel Nam, Taewoo Jeong, Yonghwa Kim, Donghyuk Kim, Kyoung-Nam Study on the Effect of Non-Symmetrical Current Distribution Controlled by Capacitor Placement in Radio-Frequency Coils for 7T MRI |
title | Study on the Effect of Non-Symmetrical Current Distribution Controlled by Capacitor Placement in Radio-Frequency Coils for 7T MRI |
title_full | Study on the Effect of Non-Symmetrical Current Distribution Controlled by Capacitor Placement in Radio-Frequency Coils for 7T MRI |
title_fullStr | Study on the Effect of Non-Symmetrical Current Distribution Controlled by Capacitor Placement in Radio-Frequency Coils for 7T MRI |
title_full_unstemmed | Study on the Effect of Non-Symmetrical Current Distribution Controlled by Capacitor Placement in Radio-Frequency Coils for 7T MRI |
title_short | Study on the Effect of Non-Symmetrical Current Distribution Controlled by Capacitor Placement in Radio-Frequency Coils for 7T MRI |
title_sort | study on the effect of non-symmetrical current distribution controlled by capacitor placement in radio-frequency coils for 7t mri |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9599509/ https://www.ncbi.nlm.nih.gov/pubmed/36291004 http://dx.doi.org/10.3390/bios12100867 |
work_keys_str_mv | AT hernandezdaniel studyontheeffectofnonsymmetricalcurrentdistributioncontrolledbycapacitorplacementinradiofrequencycoilsfor7tmri AT namtaewoo studyontheeffectofnonsymmetricalcurrentdistributioncontrolledbycapacitorplacementinradiofrequencycoilsfor7tmri AT jeongyonghwa studyontheeffectofnonsymmetricalcurrentdistributioncontrolledbycapacitorplacementinradiofrequencycoilsfor7tmri AT kimdonghyuk studyontheeffectofnonsymmetricalcurrentdistributioncontrolledbycapacitorplacementinradiofrequencycoilsfor7tmri AT kimkyoungnam studyontheeffectofnonsymmetricalcurrentdistributioncontrolledbycapacitorplacementinradiofrequencycoilsfor7tmri |