Cargando…
Prospective Evaluation of 3 T MRI Effect on Residual Hearing Function of Cochlea Implantees
Introduction: The approval process for MRI safety of implants includes physical observations and an experimental evaluation in artificial settings to simulate the in vivo effect. This contains the observation of temperature changes and artificial current generation by the magnetic field. From these...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9599932/ https://www.ncbi.nlm.nih.gov/pubmed/36291339 http://dx.doi.org/10.3390/brainsci12101406 |
_version_ | 1784816715608096768 |
---|---|
author | Eichler, Theda Ibrahim, Ahmed Riemann, Conrad Scholtz, Lars Uwe Gehl, Hans Björn Goon, Peter Sudhoff, Holger Todt, Ingo |
author_facet | Eichler, Theda Ibrahim, Ahmed Riemann, Conrad Scholtz, Lars Uwe Gehl, Hans Björn Goon, Peter Sudhoff, Holger Todt, Ingo |
author_sort | Eichler, Theda |
collection | PubMed |
description | Introduction: The approval process for MRI safety of implants includes physical observations and an experimental evaluation in artificial settings to simulate the in vivo effect. This contains the observation of temperature changes and artificial current generation by the magnetic field. From these findings, the safety of an implant and its effect on the patient can be estimated. MRI safety is based on an in vivo evaluation of adverse events after the approval process, but an actual analysis of the effect on different tissues is not followed. The effect of MRI scanning in cochlea implantees on their residual hearing as the correlate of the hair cell function is so far unknown, therefore the aim of the present study was to observe the effect of 3 T MRI on the residual hearing of cochlea implantees. Material and Methods: In this prospective study, we performed a 3 T MRI T2 2D MS Drive sequence in eight cochlea-implanted ears. Before and after the MRI scan, a bone conduction pure tone audiogram (BC PTA) was performed. All cochlea implantees had a pre-scanning threshold of low frequency residual hearing between 20 dB and 65 dB. Results: Low frequency mean residual hearing was not affected by the 3 T T2 2D MS Drive sequence. We observed a pre-scanning threshold at 250 Hz of 42.9 (SD 3.9) dB and for 500 Hz 57.1 (SD 6.4) dB. Post-scanning BC PTA was for 250 Hz 42.1 (SD 3.9) dB and for 500 Hz 57.1 (SD 5.7) dB. Conclusion: 3 T MRI scanning has no significant functional effect on the hair cells in cochlea implantees in low frequencies with a T2 2D MS Drive sequence. |
format | Online Article Text |
id | pubmed-9599932 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-95999322022-10-27 Prospective Evaluation of 3 T MRI Effect on Residual Hearing Function of Cochlea Implantees Eichler, Theda Ibrahim, Ahmed Riemann, Conrad Scholtz, Lars Uwe Gehl, Hans Björn Goon, Peter Sudhoff, Holger Todt, Ingo Brain Sci Perspective Introduction: The approval process for MRI safety of implants includes physical observations and an experimental evaluation in artificial settings to simulate the in vivo effect. This contains the observation of temperature changes and artificial current generation by the magnetic field. From these findings, the safety of an implant and its effect on the patient can be estimated. MRI safety is based on an in vivo evaluation of adverse events after the approval process, but an actual analysis of the effect on different tissues is not followed. The effect of MRI scanning in cochlea implantees on their residual hearing as the correlate of the hair cell function is so far unknown, therefore the aim of the present study was to observe the effect of 3 T MRI on the residual hearing of cochlea implantees. Material and Methods: In this prospective study, we performed a 3 T MRI T2 2D MS Drive sequence in eight cochlea-implanted ears. Before and after the MRI scan, a bone conduction pure tone audiogram (BC PTA) was performed. All cochlea implantees had a pre-scanning threshold of low frequency residual hearing between 20 dB and 65 dB. Results: Low frequency mean residual hearing was not affected by the 3 T T2 2D MS Drive sequence. We observed a pre-scanning threshold at 250 Hz of 42.9 (SD 3.9) dB and for 500 Hz 57.1 (SD 6.4) dB. Post-scanning BC PTA was for 250 Hz 42.1 (SD 3.9) dB and for 500 Hz 57.1 (SD 5.7) dB. Conclusion: 3 T MRI scanning has no significant functional effect on the hair cells in cochlea implantees in low frequencies with a T2 2D MS Drive sequence. MDPI 2022-10-19 /pmc/articles/PMC9599932/ /pubmed/36291339 http://dx.doi.org/10.3390/brainsci12101406 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Perspective Eichler, Theda Ibrahim, Ahmed Riemann, Conrad Scholtz, Lars Uwe Gehl, Hans Björn Goon, Peter Sudhoff, Holger Todt, Ingo Prospective Evaluation of 3 T MRI Effect on Residual Hearing Function of Cochlea Implantees |
title | Prospective Evaluation of 3 T MRI Effect on Residual Hearing Function of Cochlea Implantees |
title_full | Prospective Evaluation of 3 T MRI Effect on Residual Hearing Function of Cochlea Implantees |
title_fullStr | Prospective Evaluation of 3 T MRI Effect on Residual Hearing Function of Cochlea Implantees |
title_full_unstemmed | Prospective Evaluation of 3 T MRI Effect on Residual Hearing Function of Cochlea Implantees |
title_short | Prospective Evaluation of 3 T MRI Effect on Residual Hearing Function of Cochlea Implantees |
title_sort | prospective evaluation of 3 t mri effect on residual hearing function of cochlea implantees |
topic | Perspective |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9599932/ https://www.ncbi.nlm.nih.gov/pubmed/36291339 http://dx.doi.org/10.3390/brainsci12101406 |
work_keys_str_mv | AT eichlertheda prospectiveevaluationof3tmrieffectonresidualhearingfunctionofcochleaimplantees AT ibrahimahmed prospectiveevaluationof3tmrieffectonresidualhearingfunctionofcochleaimplantees AT riemannconrad prospectiveevaluationof3tmrieffectonresidualhearingfunctionofcochleaimplantees AT scholtzlarsuwe prospectiveevaluationof3tmrieffectonresidualhearingfunctionofcochleaimplantees AT gehlhansbjorn prospectiveevaluationof3tmrieffectonresidualhearingfunctionofcochleaimplantees AT goonpeter prospectiveevaluationof3tmrieffectonresidualhearingfunctionofcochleaimplantees AT sudhoffholger prospectiveevaluationof3tmrieffectonresidualhearingfunctionofcochleaimplantees AT todtingo prospectiveevaluationof3tmrieffectonresidualhearingfunctionofcochleaimplantees |