Cargando…
Real-Time (iOCT) Guided Epiretinal Membrane Surgery Using a Novel Forceps with Laser-Ablated Microstructure Tip Surface
Purpose: We investigated intraoperative OCT (iOCT)—guided epiretinal membrane (ERM) and internal limiting membrane (ILM) removal using a novel forceps with a laser-ablated tip surface; it was designed to help prevent indentation force, shear stress, or tractional trauma when grasping very fine membr...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9599977/ https://www.ncbi.nlm.nih.gov/pubmed/36286072 http://dx.doi.org/10.3390/clinpract12050086 |
_version_ | 1784816726747119616 |
---|---|
author | Ashurov, Agharza Chronopoulos, Argyrios Heim, Julia Schutz, James Scott Arndt, Carl Hattenbach, Lars-Olof |
author_facet | Ashurov, Agharza Chronopoulos, Argyrios Heim, Julia Schutz, James Scott Arndt, Carl Hattenbach, Lars-Olof |
author_sort | Ashurov, Agharza |
collection | PubMed |
description | Purpose: We investigated intraoperative OCT (iOCT)—guided epiretinal membrane (ERM) and internal limiting membrane (ILM) removal using a novel forceps with a laser-ablated tip surface; it was designed to help prevent indentation force, shear stress, or tractional trauma when grasping very fine membranes. Patients and Methods: This retrospective study included patients who underwent 23- and 25-gauge pars plana vitrectomy (PPV) for vitreoretinal interface disorders. ERM and ILM peeling was performed under guidance with microscope-integrated iOCT using novel ILM forceps with laser-ablated tip surfaces. These forceps were engineered to enhance friction when grasping tissue. Evaluation of ERM/ILM manipulation included postoperative slow-motion video analysis of the number of grasping attempts, initial ILM mobilization, and observed damage to retinal tissue. Results: ERM/ILM removal was successfully performed in all patients, with an average of four grasp actions to initial membrane mobilization (91%). Additional use of a diamond-dusted membrane scraper was used in two cases (9%). Mean best-recorded visual acuity (BRVA) logMAR improved from 0.5 ± 0.34 to 0.33 ± 0.36 (p = 0.05) and mean central retinal thickness (CRT) improved from 462 ± 146 µm to 359 ± 78 µm (p = 0.002). Postoperative iOCT video analysis demonstrated hyper-reflectivity of the inner retinal layers associated with retinal hemorrhage in five eyes (22%), but no grasping-related retinal breaks. Conclusions: The texturized surface on the tips of the ILM forceps were found to be helpful for mobilizing ILM edges from the retinal surface. iOCT-guided ERM surgery also allowed for improved intraoperative tissue visualization. We believe that these two technologies helped reduce both unnecessary surgical maneuvers and retinal damage. |
format | Online Article Text |
id | pubmed-9599977 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-95999772022-10-27 Real-Time (iOCT) Guided Epiretinal Membrane Surgery Using a Novel Forceps with Laser-Ablated Microstructure Tip Surface Ashurov, Agharza Chronopoulos, Argyrios Heim, Julia Schutz, James Scott Arndt, Carl Hattenbach, Lars-Olof Clin Pract Article Purpose: We investigated intraoperative OCT (iOCT)—guided epiretinal membrane (ERM) and internal limiting membrane (ILM) removal using a novel forceps with a laser-ablated tip surface; it was designed to help prevent indentation force, shear stress, or tractional trauma when grasping very fine membranes. Patients and Methods: This retrospective study included patients who underwent 23- and 25-gauge pars plana vitrectomy (PPV) for vitreoretinal interface disorders. ERM and ILM peeling was performed under guidance with microscope-integrated iOCT using novel ILM forceps with laser-ablated tip surfaces. These forceps were engineered to enhance friction when grasping tissue. Evaluation of ERM/ILM manipulation included postoperative slow-motion video analysis of the number of grasping attempts, initial ILM mobilization, and observed damage to retinal tissue. Results: ERM/ILM removal was successfully performed in all patients, with an average of four grasp actions to initial membrane mobilization (91%). Additional use of a diamond-dusted membrane scraper was used in two cases (9%). Mean best-recorded visual acuity (BRVA) logMAR improved from 0.5 ± 0.34 to 0.33 ± 0.36 (p = 0.05) and mean central retinal thickness (CRT) improved from 462 ± 146 µm to 359 ± 78 µm (p = 0.002). Postoperative iOCT video analysis demonstrated hyper-reflectivity of the inner retinal layers associated with retinal hemorrhage in five eyes (22%), but no grasping-related retinal breaks. Conclusions: The texturized surface on the tips of the ILM forceps were found to be helpful for mobilizing ILM edges from the retinal surface. iOCT-guided ERM surgery also allowed for improved intraoperative tissue visualization. We believe that these two technologies helped reduce both unnecessary surgical maneuvers and retinal damage. MDPI 2022-10-10 /pmc/articles/PMC9599977/ /pubmed/36286072 http://dx.doi.org/10.3390/clinpract12050086 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ashurov, Agharza Chronopoulos, Argyrios Heim, Julia Schutz, James Scott Arndt, Carl Hattenbach, Lars-Olof Real-Time (iOCT) Guided Epiretinal Membrane Surgery Using a Novel Forceps with Laser-Ablated Microstructure Tip Surface |
title | Real-Time (iOCT) Guided Epiretinal Membrane Surgery Using a Novel Forceps with Laser-Ablated Microstructure Tip Surface |
title_full | Real-Time (iOCT) Guided Epiretinal Membrane Surgery Using a Novel Forceps with Laser-Ablated Microstructure Tip Surface |
title_fullStr | Real-Time (iOCT) Guided Epiretinal Membrane Surgery Using a Novel Forceps with Laser-Ablated Microstructure Tip Surface |
title_full_unstemmed | Real-Time (iOCT) Guided Epiretinal Membrane Surgery Using a Novel Forceps with Laser-Ablated Microstructure Tip Surface |
title_short | Real-Time (iOCT) Guided Epiretinal Membrane Surgery Using a Novel Forceps with Laser-Ablated Microstructure Tip Surface |
title_sort | real-time (ioct) guided epiretinal membrane surgery using a novel forceps with laser-ablated microstructure tip surface |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9599977/ https://www.ncbi.nlm.nih.gov/pubmed/36286072 http://dx.doi.org/10.3390/clinpract12050086 |
work_keys_str_mv | AT ashurovagharza realtimeioctguidedepiretinalmembranesurgeryusinganovelforcepswithlaserablatedmicrostructuretipsurface AT chronopoulosargyrios realtimeioctguidedepiretinalmembranesurgeryusinganovelforcepswithlaserablatedmicrostructuretipsurface AT heimjulia realtimeioctguidedepiretinalmembranesurgeryusinganovelforcepswithlaserablatedmicrostructuretipsurface AT schutzjamesscott realtimeioctguidedepiretinalmembranesurgeryusinganovelforcepswithlaserablatedmicrostructuretipsurface AT arndtcarl realtimeioctguidedepiretinalmembranesurgeryusinganovelforcepswithlaserablatedmicrostructuretipsurface AT hattenbachlarsolof realtimeioctguidedepiretinalmembranesurgeryusinganovelforcepswithlaserablatedmicrostructuretipsurface |