Cargando…

Real-Time (iOCT) Guided Epiretinal Membrane Surgery Using a Novel Forceps with Laser-Ablated Microstructure Tip Surface

Purpose: We investigated intraoperative OCT (iOCT)—guided epiretinal membrane (ERM) and internal limiting membrane (ILM) removal using a novel forceps with a laser-ablated tip surface; it was designed to help prevent indentation force, shear stress, or tractional trauma when grasping very fine membr...

Descripción completa

Detalles Bibliográficos
Autores principales: Ashurov, Agharza, Chronopoulos, Argyrios, Heim, Julia, Schutz, James Scott, Arndt, Carl, Hattenbach, Lars-Olof
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9599977/
https://www.ncbi.nlm.nih.gov/pubmed/36286072
http://dx.doi.org/10.3390/clinpract12050086
_version_ 1784816726747119616
author Ashurov, Agharza
Chronopoulos, Argyrios
Heim, Julia
Schutz, James Scott
Arndt, Carl
Hattenbach, Lars-Olof
author_facet Ashurov, Agharza
Chronopoulos, Argyrios
Heim, Julia
Schutz, James Scott
Arndt, Carl
Hattenbach, Lars-Olof
author_sort Ashurov, Agharza
collection PubMed
description Purpose: We investigated intraoperative OCT (iOCT)—guided epiretinal membrane (ERM) and internal limiting membrane (ILM) removal using a novel forceps with a laser-ablated tip surface; it was designed to help prevent indentation force, shear stress, or tractional trauma when grasping very fine membranes. Patients and Methods: This retrospective study included patients who underwent 23- and 25-gauge pars plana vitrectomy (PPV) for vitreoretinal interface disorders. ERM and ILM peeling was performed under guidance with microscope-integrated iOCT using novel ILM forceps with laser-ablated tip surfaces. These forceps were engineered to enhance friction when grasping tissue. Evaluation of ERM/ILM manipulation included postoperative slow-motion video analysis of the number of grasping attempts, initial ILM mobilization, and observed damage to retinal tissue. Results: ERM/ILM removal was successfully performed in all patients, with an average of four grasp actions to initial membrane mobilization (91%). Additional use of a diamond-dusted membrane scraper was used in two cases (9%). Mean best-recorded visual acuity (BRVA) logMAR improved from 0.5 ± 0.34 to 0.33 ± 0.36 (p = 0.05) and mean central retinal thickness (CRT) improved from 462 ± 146 µm to 359 ± 78 µm (p = 0.002). Postoperative iOCT video analysis demonstrated hyper-reflectivity of the inner retinal layers associated with retinal hemorrhage in five eyes (22%), but no grasping-related retinal breaks. Conclusions: The texturized surface on the tips of the ILM forceps were found to be helpful for mobilizing ILM edges from the retinal surface. iOCT-guided ERM surgery also allowed for improved intraoperative tissue visualization. We believe that these two technologies helped reduce both unnecessary surgical maneuvers and retinal damage.
format Online
Article
Text
id pubmed-9599977
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-95999772022-10-27 Real-Time (iOCT) Guided Epiretinal Membrane Surgery Using a Novel Forceps with Laser-Ablated Microstructure Tip Surface Ashurov, Agharza Chronopoulos, Argyrios Heim, Julia Schutz, James Scott Arndt, Carl Hattenbach, Lars-Olof Clin Pract Article Purpose: We investigated intraoperative OCT (iOCT)—guided epiretinal membrane (ERM) and internal limiting membrane (ILM) removal using a novel forceps with a laser-ablated tip surface; it was designed to help prevent indentation force, shear stress, or tractional trauma when grasping very fine membranes. Patients and Methods: This retrospective study included patients who underwent 23- and 25-gauge pars plana vitrectomy (PPV) for vitreoretinal interface disorders. ERM and ILM peeling was performed under guidance with microscope-integrated iOCT using novel ILM forceps with laser-ablated tip surfaces. These forceps were engineered to enhance friction when grasping tissue. Evaluation of ERM/ILM manipulation included postoperative slow-motion video analysis of the number of grasping attempts, initial ILM mobilization, and observed damage to retinal tissue. Results: ERM/ILM removal was successfully performed in all patients, with an average of four grasp actions to initial membrane mobilization (91%). Additional use of a diamond-dusted membrane scraper was used in two cases (9%). Mean best-recorded visual acuity (BRVA) logMAR improved from 0.5 ± 0.34 to 0.33 ± 0.36 (p = 0.05) and mean central retinal thickness (CRT) improved from 462 ± 146 µm to 359 ± 78 µm (p = 0.002). Postoperative iOCT video analysis demonstrated hyper-reflectivity of the inner retinal layers associated with retinal hemorrhage in five eyes (22%), but no grasping-related retinal breaks. Conclusions: The texturized surface on the tips of the ILM forceps were found to be helpful for mobilizing ILM edges from the retinal surface. iOCT-guided ERM surgery also allowed for improved intraoperative tissue visualization. We believe that these two technologies helped reduce both unnecessary surgical maneuvers and retinal damage. MDPI 2022-10-10 /pmc/articles/PMC9599977/ /pubmed/36286072 http://dx.doi.org/10.3390/clinpract12050086 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ashurov, Agharza
Chronopoulos, Argyrios
Heim, Julia
Schutz, James Scott
Arndt, Carl
Hattenbach, Lars-Olof
Real-Time (iOCT) Guided Epiretinal Membrane Surgery Using a Novel Forceps with Laser-Ablated Microstructure Tip Surface
title Real-Time (iOCT) Guided Epiretinal Membrane Surgery Using a Novel Forceps with Laser-Ablated Microstructure Tip Surface
title_full Real-Time (iOCT) Guided Epiretinal Membrane Surgery Using a Novel Forceps with Laser-Ablated Microstructure Tip Surface
title_fullStr Real-Time (iOCT) Guided Epiretinal Membrane Surgery Using a Novel Forceps with Laser-Ablated Microstructure Tip Surface
title_full_unstemmed Real-Time (iOCT) Guided Epiretinal Membrane Surgery Using a Novel Forceps with Laser-Ablated Microstructure Tip Surface
title_short Real-Time (iOCT) Guided Epiretinal Membrane Surgery Using a Novel Forceps with Laser-Ablated Microstructure Tip Surface
title_sort real-time (ioct) guided epiretinal membrane surgery using a novel forceps with laser-ablated microstructure tip surface
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9599977/
https://www.ncbi.nlm.nih.gov/pubmed/36286072
http://dx.doi.org/10.3390/clinpract12050086
work_keys_str_mv AT ashurovagharza realtimeioctguidedepiretinalmembranesurgeryusinganovelforcepswithlaserablatedmicrostructuretipsurface
AT chronopoulosargyrios realtimeioctguidedepiretinalmembranesurgeryusinganovelforcepswithlaserablatedmicrostructuretipsurface
AT heimjulia realtimeioctguidedepiretinalmembranesurgeryusinganovelforcepswithlaserablatedmicrostructuretipsurface
AT schutzjamesscott realtimeioctguidedepiretinalmembranesurgeryusinganovelforcepswithlaserablatedmicrostructuretipsurface
AT arndtcarl realtimeioctguidedepiretinalmembranesurgeryusinganovelforcepswithlaserablatedmicrostructuretipsurface
AT hattenbachlarsolof realtimeioctguidedepiretinalmembranesurgeryusinganovelforcepswithlaserablatedmicrostructuretipsurface