Challenges Associated with Effective Implementation of CT Dose Check Standards and Radiation Monitoring Index in Computed Tomography: Healthcare Sector Experience
Computed tomography (CT) radiation dose management tools should be used whenever possible, particularly with the increasing demand for acquiring CT studies. Herein, we aim to assess the advantages and challenges faced with implementing two CT dose management tools. A second aim was to highlight CT e...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9601746/ https://www.ncbi.nlm.nih.gov/pubmed/36292417 http://dx.doi.org/10.3390/healthcare10101970 |
_version_ | 1784817142164619264 |
---|---|
author | Dalah, Entesar Zawam Al Musfari, Yousuf Mohammad Ali, Badriya Mohd Hassan Al Hammadi, Anwaar Abdulrahim Beevi, Hashim Abdul Azeez Jaber, Manal Ibrahim Al-Ali, Alyazya Akeel Alkharoossi, Ayesha Khalid Hashemi, Fairooz Hussain Al Alkhatib, Fatma Mahmood Khan, Sabaa Anam Aqil |
author_facet | Dalah, Entesar Zawam Al Musfari, Yousuf Mohammad Ali, Badriya Mohd Hassan Al Hammadi, Anwaar Abdulrahim Beevi, Hashim Abdul Azeez Jaber, Manal Ibrahim Al-Ali, Alyazya Akeel Alkharoossi, Ayesha Khalid Hashemi, Fairooz Hussain Al Alkhatib, Fatma Mahmood Khan, Sabaa Anam Aqil |
author_sort | Dalah, Entesar Zawam |
collection | PubMed |
description | Computed tomography (CT) radiation dose management tools should be used whenever possible, particularly with the increasing demand for acquiring CT studies. Herein, we aim to assess the advantages and challenges faced with implementing two CT dose management tools. A second aim was to highlight CT examinations exceeding dose notification values (NVs) and define the common set of causes. A total of 13,037 CT examinations collected over a six-month period, were evaluated, using two independent CT dose management tools, a CT Dose Notification prospective-view tool (PVT) following CT Dose Check standards and a retrospective statistical-based view tool (RSVT). Dose NVs were set to twice the Local Diagnostic Reference Levels. There was a significant discrepancy between dose NV counts registered with prospective (4.15%) and retrospective (7.98%) tools using T-Test. A core difference is the dose configuration setup, with PVT and RSVT being dose per series and whole study, respectively. Both prospective and retrospective dose management tools were equally useful despite their technical difference. Configuring the CT prospective dose notification check tool using NVs that is based on DRLs has limitations, and one needs to establish dose NVs per series to overcome this technical hurdle. Technical challenges make the implementation of CT Dose Check standards puzzling. |
format | Online Article Text |
id | pubmed-9601746 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96017462022-10-27 Challenges Associated with Effective Implementation of CT Dose Check Standards and Radiation Monitoring Index in Computed Tomography: Healthcare Sector Experience Dalah, Entesar Zawam Al Musfari, Yousuf Mohammad Ali, Badriya Mohd Hassan Al Hammadi, Anwaar Abdulrahim Beevi, Hashim Abdul Azeez Jaber, Manal Ibrahim Al-Ali, Alyazya Akeel Alkharoossi, Ayesha Khalid Hashemi, Fairooz Hussain Al Alkhatib, Fatma Mahmood Khan, Sabaa Anam Aqil Healthcare (Basel) Article Computed tomography (CT) radiation dose management tools should be used whenever possible, particularly with the increasing demand for acquiring CT studies. Herein, we aim to assess the advantages and challenges faced with implementing two CT dose management tools. A second aim was to highlight CT examinations exceeding dose notification values (NVs) and define the common set of causes. A total of 13,037 CT examinations collected over a six-month period, were evaluated, using two independent CT dose management tools, a CT Dose Notification prospective-view tool (PVT) following CT Dose Check standards and a retrospective statistical-based view tool (RSVT). Dose NVs were set to twice the Local Diagnostic Reference Levels. There was a significant discrepancy between dose NV counts registered with prospective (4.15%) and retrospective (7.98%) tools using T-Test. A core difference is the dose configuration setup, with PVT and RSVT being dose per series and whole study, respectively. Both prospective and retrospective dose management tools were equally useful despite their technical difference. Configuring the CT prospective dose notification check tool using NVs that is based on DRLs has limitations, and one needs to establish dose NVs per series to overcome this technical hurdle. Technical challenges make the implementation of CT Dose Check standards puzzling. MDPI 2022-10-08 /pmc/articles/PMC9601746/ /pubmed/36292417 http://dx.doi.org/10.3390/healthcare10101970 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Dalah, Entesar Zawam Al Musfari, Yousuf Mohammad Ali, Badriya Mohd Hassan Al Hammadi, Anwaar Abdulrahim Beevi, Hashim Abdul Azeez Jaber, Manal Ibrahim Al-Ali, Alyazya Akeel Alkharoossi, Ayesha Khalid Hashemi, Fairooz Hussain Al Alkhatib, Fatma Mahmood Khan, Sabaa Anam Aqil Challenges Associated with Effective Implementation of CT Dose Check Standards and Radiation Monitoring Index in Computed Tomography: Healthcare Sector Experience |
title | Challenges Associated with Effective Implementation of CT Dose Check Standards and Radiation Monitoring Index in Computed Tomography: Healthcare Sector Experience |
title_full | Challenges Associated with Effective Implementation of CT Dose Check Standards and Radiation Monitoring Index in Computed Tomography: Healthcare Sector Experience |
title_fullStr | Challenges Associated with Effective Implementation of CT Dose Check Standards and Radiation Monitoring Index in Computed Tomography: Healthcare Sector Experience |
title_full_unstemmed | Challenges Associated with Effective Implementation of CT Dose Check Standards and Radiation Monitoring Index in Computed Tomography: Healthcare Sector Experience |
title_short | Challenges Associated with Effective Implementation of CT Dose Check Standards and Radiation Monitoring Index in Computed Tomography: Healthcare Sector Experience |
title_sort | challenges associated with effective implementation of ct dose check standards and radiation monitoring index in computed tomography: healthcare sector experience |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9601746/ https://www.ncbi.nlm.nih.gov/pubmed/36292417 http://dx.doi.org/10.3390/healthcare10101970 |
work_keys_str_mv | AT dalahentesarzawam challengesassociatedwitheffectiveimplementationofctdosecheckstandardsandradiationmonitoringindexincomputedtomographyhealthcaresectorexperience AT almusfariyousufmohammad challengesassociatedwitheffectiveimplementationofctdosecheckstandardsandradiationmonitoringindexincomputedtomographyhealthcaresectorexperience AT alibadriyamohdhassan challengesassociatedwitheffectiveimplementationofctdosecheckstandardsandradiationmonitoringindexincomputedtomographyhealthcaresectorexperience AT alhammadianwaarabdulrahim challengesassociatedwitheffectiveimplementationofctdosecheckstandardsandradiationmonitoringindexincomputedtomographyhealthcaresectorexperience AT beevihashimabdulazeez challengesassociatedwitheffectiveimplementationofctdosecheckstandardsandradiationmonitoringindexincomputedtomographyhealthcaresectorexperience AT jabermanalibrahim challengesassociatedwitheffectiveimplementationofctdosecheckstandardsandradiationmonitoringindexincomputedtomographyhealthcaresectorexperience AT alalialyazyaakeel challengesassociatedwitheffectiveimplementationofctdosecheckstandardsandradiationmonitoringindexincomputedtomographyhealthcaresectorexperience AT alkharoossiayeshakhalid challengesassociatedwitheffectiveimplementationofctdosecheckstandardsandradiationmonitoringindexincomputedtomographyhealthcaresectorexperience AT hashemifairoozhussainal challengesassociatedwitheffectiveimplementationofctdosecheckstandardsandradiationmonitoringindexincomputedtomographyhealthcaresectorexperience AT alkhatibfatmamahmood challengesassociatedwitheffectiveimplementationofctdosecheckstandardsandradiationmonitoringindexincomputedtomographyhealthcaresectorexperience AT khansabaaanamaqil challengesassociatedwitheffectiveimplementationofctdosecheckstandardsandradiationmonitoringindexincomputedtomographyhealthcaresectorexperience |