Cargando…

Determination of Hydroxy Polycyclic Aromatic Hydrocarbons in Human Urine Using Automated Microextraction by Packed Sorbent and Gas Chromatography–Mass Spectrometry

A fast methodology for the determination of monohydroxy polycyclic aromatic hydrocarbons in human urine using a fully automated microextraction by packed sorbent coupled to a gas chromatograph–mass spectrometer is reported. Sample preparation requires simple hydrolysis, centrifugation, filtration, a...

Descripción completa

Detalles Bibliográficos
Autores principales: García-García, Samuel, Matilla-González, Héctor, Peña, Javier, del Nogal Sánchez, Miguel, Casas-Ferreira, Ana María, Pérez Pavón, José Luis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9602966/
https://www.ncbi.nlm.nih.gov/pubmed/36293669
http://dx.doi.org/10.3390/ijerph192013089
_version_ 1784817434685865984
author García-García, Samuel
Matilla-González, Héctor
Peña, Javier
del Nogal Sánchez, Miguel
Casas-Ferreira, Ana María
Pérez Pavón, José Luis
author_facet García-García, Samuel
Matilla-González, Héctor
Peña, Javier
del Nogal Sánchez, Miguel
Casas-Ferreira, Ana María
Pérez Pavón, José Luis
author_sort García-García, Samuel
collection PubMed
description A fast methodology for the determination of monohydroxy polycyclic aromatic hydrocarbons in human urine using a fully automated microextraction by packed sorbent coupled to a gas chromatograph–mass spectrometer is reported. Sample preparation requires simple hydrolysis, centrifugation, filtration, and dilution. The method does not require a derivatization step prior to analysis with gas chromatography and allows the measurement of up to three samples per hour after hydrolysis. Quantitation is carried out by a one-point standard addition allowing the determination of 6 analytes with good limits of detection (10.1–39.6 ng L(−1) in water and 0.5–19.4 µg L(−1) in urine), accuracy (88–110%) and precision (2.1–23.4% in water and 5.1–19.0% in urine) values. This method has been successfully applied to the analysis of six urine samples (three from smoker and three from non-smoker subjects), finding significant differences between both types of samples. Results were similar to those found in the literature for similar samples, which proves the applicability of the methodology.
format Online
Article
Text
id pubmed-9602966
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96029662022-10-27 Determination of Hydroxy Polycyclic Aromatic Hydrocarbons in Human Urine Using Automated Microextraction by Packed Sorbent and Gas Chromatography–Mass Spectrometry García-García, Samuel Matilla-González, Héctor Peña, Javier del Nogal Sánchez, Miguel Casas-Ferreira, Ana María Pérez Pavón, José Luis Int J Environ Res Public Health Article A fast methodology for the determination of monohydroxy polycyclic aromatic hydrocarbons in human urine using a fully automated microextraction by packed sorbent coupled to a gas chromatograph–mass spectrometer is reported. Sample preparation requires simple hydrolysis, centrifugation, filtration, and dilution. The method does not require a derivatization step prior to analysis with gas chromatography and allows the measurement of up to three samples per hour after hydrolysis. Quantitation is carried out by a one-point standard addition allowing the determination of 6 analytes with good limits of detection (10.1–39.6 ng L(−1) in water and 0.5–19.4 µg L(−1) in urine), accuracy (88–110%) and precision (2.1–23.4% in water and 5.1–19.0% in urine) values. This method has been successfully applied to the analysis of six urine samples (three from smoker and three from non-smoker subjects), finding significant differences between both types of samples. Results were similar to those found in the literature for similar samples, which proves the applicability of the methodology. MDPI 2022-10-12 /pmc/articles/PMC9602966/ /pubmed/36293669 http://dx.doi.org/10.3390/ijerph192013089 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
García-García, Samuel
Matilla-González, Héctor
Peña, Javier
del Nogal Sánchez, Miguel
Casas-Ferreira, Ana María
Pérez Pavón, José Luis
Determination of Hydroxy Polycyclic Aromatic Hydrocarbons in Human Urine Using Automated Microextraction by Packed Sorbent and Gas Chromatography–Mass Spectrometry
title Determination of Hydroxy Polycyclic Aromatic Hydrocarbons in Human Urine Using Automated Microextraction by Packed Sorbent and Gas Chromatography–Mass Spectrometry
title_full Determination of Hydroxy Polycyclic Aromatic Hydrocarbons in Human Urine Using Automated Microextraction by Packed Sorbent and Gas Chromatography–Mass Spectrometry
title_fullStr Determination of Hydroxy Polycyclic Aromatic Hydrocarbons in Human Urine Using Automated Microextraction by Packed Sorbent and Gas Chromatography–Mass Spectrometry
title_full_unstemmed Determination of Hydroxy Polycyclic Aromatic Hydrocarbons in Human Urine Using Automated Microextraction by Packed Sorbent and Gas Chromatography–Mass Spectrometry
title_short Determination of Hydroxy Polycyclic Aromatic Hydrocarbons in Human Urine Using Automated Microextraction by Packed Sorbent and Gas Chromatography–Mass Spectrometry
title_sort determination of hydroxy polycyclic aromatic hydrocarbons in human urine using automated microextraction by packed sorbent and gas chromatography–mass spectrometry
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9602966/
https://www.ncbi.nlm.nih.gov/pubmed/36293669
http://dx.doi.org/10.3390/ijerph192013089
work_keys_str_mv AT garciagarciasamuel determinationofhydroxypolycyclicaromatichydrocarbonsinhumanurineusingautomatedmicroextractionbypackedsorbentandgaschromatographymassspectrometry
AT matillagonzalezhector determinationofhydroxypolycyclicaromatichydrocarbonsinhumanurineusingautomatedmicroextractionbypackedsorbentandgaschromatographymassspectrometry
AT penajavier determinationofhydroxypolycyclicaromatichydrocarbonsinhumanurineusingautomatedmicroextractionbypackedsorbentandgaschromatographymassspectrometry
AT delnogalsanchezmiguel determinationofhydroxypolycyclicaromatichydrocarbonsinhumanurineusingautomatedmicroextractionbypackedsorbentandgaschromatographymassspectrometry
AT casasferreiraanamaria determinationofhydroxypolycyclicaromatichydrocarbonsinhumanurineusingautomatedmicroextractionbypackedsorbentandgaschromatographymassspectrometry
AT perezpavonjoseluis determinationofhydroxypolycyclicaromatichydrocarbonsinhumanurineusingautomatedmicroextractionbypackedsorbentandgaschromatographymassspectrometry