Cargando…
Pre-deployment assessment of an AI model to assist radiologists in chest X-ray detection and identification of lead-less implanted electronic devices for pre-MRI safety screening: realized implementation needs and proposed operational solutions
PURPOSE: Chest X-ray (CXR) use in pre-MRI safety screening, such as for lead-less implanted electronic device (LLIED) recognition, is common. To assist CXR interpretation, we “pre-deployed” an artificial intelligence (AI) model to assess (1) accuracies in LLIED-type (and consequently safety-level) i...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Society of Photo-Optical Instrumentation Engineers
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9603740/ https://www.ncbi.nlm.nih.gov/pubmed/36310648 http://dx.doi.org/10.1117/1.JMI.9.5.054504 |
_version_ | 1784817631030673408 |
---|---|
author | White, Richard D. Demirer, Mutlu Gupta, Vikash Sebro, Ronnie A. Kusumoto, Frederick M. Erdal, Barbaros Selnur |
author_facet | White, Richard D. Demirer, Mutlu Gupta, Vikash Sebro, Ronnie A. Kusumoto, Frederick M. Erdal, Barbaros Selnur |
author_sort | White, Richard D. |
collection | PubMed |
description | PURPOSE: Chest X-ray (CXR) use in pre-MRI safety screening, such as for lead-less implanted electronic device (LLIED) recognition, is common. To assist CXR interpretation, we “pre-deployed” an artificial intelligence (AI) model to assess (1) accuracies in LLIED-type (and consequently safety-level) identification, (2) safety implications of LLIED nondetections or misidentifications, (3) infrastructural or workflow requirements, and (4) demands related to model adaptation to real-world conditions. APPROACH: A two-tier cascading methodology for LLIED detection/localization and identification on a frontal CXR was applied to evaluate the performance of the original nine-class AI model. With the unexpected early appearance of LLIED types during simulated real-world trialing, retraining of a newer 12-class version preceded retrialing. A zero footprint (ZF) graphical user interface (GUI)/viewer with DICOM-based output was developed for inference-result display and adjudication, supporting end-user engagement and model continuous learning and/or modernization. RESULTS: During model testing or trialing using both the nine-class and 12-class models, robust detection/localization was consistently 100%, with mAP 0.99 from fivefold cross-validation. Safety-level categorization was high during both testing ([Formula: see text] and [Formula: see text] , respectively) and trialing (accuracy 98% and 97%, respectively). LLIED-type identifications by the two models during testing (1) were 98.9% and 99.5% overall correct and (2) consistently showed [Formula: see text] (1.00 for 8/9 and 9/12 LLIED-types, respectively). Pre-deployment trialing of both models demonstrated overall type-identification accuracies of 94.5% and 95%, respectively. Of the small number of misidentifications, none involved MRI-stringently conditional or MRI-unsafe types of LLIEDs. Optimized ZF GUI/viewer operations led to greater user-friendliness for radiologist engagement. CONCLUSIONS: Our LLIED-related AI methodology supports (1) 100% detection sensitivity, (2) high identification (including MRI-safety) accuracy, and (3) future model deployment with facilitated inference-result display and adjudication for ongoing model adaptation to future real-world experiences. |
format | Online Article Text |
id | pubmed-9603740 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Society of Photo-Optical Instrumentation Engineers |
record_format | MEDLINE/PubMed |
spelling | pubmed-96037402023-10-26 Pre-deployment assessment of an AI model to assist radiologists in chest X-ray detection and identification of lead-less implanted electronic devices for pre-MRI safety screening: realized implementation needs and proposed operational solutions White, Richard D. Demirer, Mutlu Gupta, Vikash Sebro, Ronnie A. Kusumoto, Frederick M. Erdal, Barbaros Selnur J Med Imaging (Bellingham) Computer-Aided Diagnosis PURPOSE: Chest X-ray (CXR) use in pre-MRI safety screening, such as for lead-less implanted electronic device (LLIED) recognition, is common. To assist CXR interpretation, we “pre-deployed” an artificial intelligence (AI) model to assess (1) accuracies in LLIED-type (and consequently safety-level) identification, (2) safety implications of LLIED nondetections or misidentifications, (3) infrastructural or workflow requirements, and (4) demands related to model adaptation to real-world conditions. APPROACH: A two-tier cascading methodology for LLIED detection/localization and identification on a frontal CXR was applied to evaluate the performance of the original nine-class AI model. With the unexpected early appearance of LLIED types during simulated real-world trialing, retraining of a newer 12-class version preceded retrialing. A zero footprint (ZF) graphical user interface (GUI)/viewer with DICOM-based output was developed for inference-result display and adjudication, supporting end-user engagement and model continuous learning and/or modernization. RESULTS: During model testing or trialing using both the nine-class and 12-class models, robust detection/localization was consistently 100%, with mAP 0.99 from fivefold cross-validation. Safety-level categorization was high during both testing ([Formula: see text] and [Formula: see text] , respectively) and trialing (accuracy 98% and 97%, respectively). LLIED-type identifications by the two models during testing (1) were 98.9% and 99.5% overall correct and (2) consistently showed [Formula: see text] (1.00 for 8/9 and 9/12 LLIED-types, respectively). Pre-deployment trialing of both models demonstrated overall type-identification accuracies of 94.5% and 95%, respectively. Of the small number of misidentifications, none involved MRI-stringently conditional or MRI-unsafe types of LLIEDs. Optimized ZF GUI/viewer operations led to greater user-friendliness for radiologist engagement. CONCLUSIONS: Our LLIED-related AI methodology supports (1) 100% detection sensitivity, (2) high identification (including MRI-safety) accuracy, and (3) future model deployment with facilitated inference-result display and adjudication for ongoing model adaptation to future real-world experiences. Society of Photo-Optical Instrumentation Engineers 2022-10-26 2022-09 /pmc/articles/PMC9603740/ /pubmed/36310648 http://dx.doi.org/10.1117/1.JMI.9.5.054504 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. |
spellingShingle | Computer-Aided Diagnosis White, Richard D. Demirer, Mutlu Gupta, Vikash Sebro, Ronnie A. Kusumoto, Frederick M. Erdal, Barbaros Selnur Pre-deployment assessment of an AI model to assist radiologists in chest X-ray detection and identification of lead-less implanted electronic devices for pre-MRI safety screening: realized implementation needs and proposed operational solutions |
title | Pre-deployment assessment of an AI model to assist radiologists in chest X-ray detection and identification of lead-less implanted electronic devices for pre-MRI safety screening: realized implementation needs and proposed operational solutions |
title_full | Pre-deployment assessment of an AI model to assist radiologists in chest X-ray detection and identification of lead-less implanted electronic devices for pre-MRI safety screening: realized implementation needs and proposed operational solutions |
title_fullStr | Pre-deployment assessment of an AI model to assist radiologists in chest X-ray detection and identification of lead-less implanted electronic devices for pre-MRI safety screening: realized implementation needs and proposed operational solutions |
title_full_unstemmed | Pre-deployment assessment of an AI model to assist radiologists in chest X-ray detection and identification of lead-less implanted electronic devices for pre-MRI safety screening: realized implementation needs and proposed operational solutions |
title_short | Pre-deployment assessment of an AI model to assist radiologists in chest X-ray detection and identification of lead-less implanted electronic devices for pre-MRI safety screening: realized implementation needs and proposed operational solutions |
title_sort | pre-deployment assessment of an ai model to assist radiologists in chest x-ray detection and identification of lead-less implanted electronic devices for pre-mri safety screening: realized implementation needs and proposed operational solutions |
topic | Computer-Aided Diagnosis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9603740/ https://www.ncbi.nlm.nih.gov/pubmed/36310648 http://dx.doi.org/10.1117/1.JMI.9.5.054504 |
work_keys_str_mv | AT whiterichardd predeploymentassessmentofanaimodeltoassistradiologistsinchestxraydetectionandidentificationofleadlessimplantedelectronicdevicesforpremrisafetyscreeningrealizedimplementationneedsandproposedoperationalsolutions AT demirermutlu predeploymentassessmentofanaimodeltoassistradiologistsinchestxraydetectionandidentificationofleadlessimplantedelectronicdevicesforpremrisafetyscreeningrealizedimplementationneedsandproposedoperationalsolutions AT guptavikash predeploymentassessmentofanaimodeltoassistradiologistsinchestxraydetectionandidentificationofleadlessimplantedelectronicdevicesforpremrisafetyscreeningrealizedimplementationneedsandproposedoperationalsolutions AT sebroronniea predeploymentassessmentofanaimodeltoassistradiologistsinchestxraydetectionandidentificationofleadlessimplantedelectronicdevicesforpremrisafetyscreeningrealizedimplementationneedsandproposedoperationalsolutions AT kusumotofrederickm predeploymentassessmentofanaimodeltoassistradiologistsinchestxraydetectionandidentificationofleadlessimplantedelectronicdevicesforpremrisafetyscreeningrealizedimplementationneedsandproposedoperationalsolutions AT erdalbarbarosselnur predeploymentassessmentofanaimodeltoassistradiologistsinchestxraydetectionandidentificationofleadlessimplantedelectronicdevicesforpremrisafetyscreeningrealizedimplementationneedsandproposedoperationalsolutions |