Comparison of Suture-Based and Collagen-Based Vascular Closure Devices for Large Bore Arteriotomies—A Meta-Analysis of Bleeding and Vascular Outcomes

Background: Large bore access procedures rely on vascular closure devices to minimize access site complications. Suture-based vascular closure devices (S-VCD) such as ProGlide and ProStar XL have been readily used, but recently, newer generation collagen-based vascular closure devices (C-VCD) such a...

Descripción completa

Detalles Bibliográficos
Autores principales: Sohal, Sumit, Mathai, Sheetal Vasundara, Nagraj, Sanjana, Kurpad, Krishna, Suthar, Kandarp, Mehta, Harsh, Kaur, Komaldeep, Wasty, Najam, Waxman, Sergio, Cohen, Marc, Visveswaran, Gautam K., Tayal, Rajiv
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9604251/
https://www.ncbi.nlm.nih.gov/pubmed/36286283
http://dx.doi.org/10.3390/jcdd9100331
Descripción
Sumario:Background: Large bore access procedures rely on vascular closure devices to minimize access site complications. Suture-based vascular closure devices (S-VCD) such as ProGlide and ProStar XL have been readily used, but recently, newer generation collagen-based vascular closure devices (C-VCD) such as MANTA have been introduced. Data on comparisons of these devices are limited. Methods: PubMed, Scopus and Cochrane were searched for articles on vascular closure devices using keywords, (“Vascular closure devices” OR “MANTA” OR “ProStar XL” OR “ProGlide”) AND (“outcomes”) that resulted in a total of 875 studies. Studies were included if bleeding or vascular complications as defined by Valve Academic Research Consortium-2 were compared between the two types of VCDs. The event level data were pooled across trials to calculate the Odds Ratio (OR) with 95% CI, and analysis was done with Review Manager 5.4 using random effects model. Results: Pooled analyses from these nine studies resulted in a total of 3410 patients, out of which 2855 were available for analysis. A total of 1229 received C-VCD and 1626 received S- VCD. Among the patients who received C-VCD, the bleeding complications (major and minor) were similar to patients who received S-VCD ((OR: 0.70 (0.35–1.39), p = 0.31, I(2) = 55%), OR: 0.92 (0.53–1.61), p = 0.77, I(2) = 65%)). The vascular complications (major and minor) in patients who received C-VCD were also similar to patients who received S-VCD ((OR: 1.01 (0.48–2.12), p = 0.98, I(2) = 52%), (OR: 0.90 (0.62–1.30), p = 0.56, I(2) = 35%)). Conclusions: Bleeding and vascular complications after large bore arteriotomy closure with collagen-based vascular closure devices are similar to suture-based vascular closure devices.