Cargando…

Prosthetic Valve Function after Aortic Valve Replacement for Severe Aortic Stenosis by Transcatheter Procedure versus Surgery

Background This study compared the clinical outcomes of transcatheter (TAVR) and surgical (SAVR) aortic valve replacements, focusing on postoperative valvular performance assessed by echocardiography. Method and Results A total of 425 patients who underwent TAVR (230 patients) or SAVR (195 patients)...

Descripción completa

Detalles Bibliográficos
Autores principales: Saito, Shunsuke, Sairenchi, Toshimi, Hirota, Shotaro, Niitsuma, Ken, Yokoyama, Shohei, Kanno, Yasuyuki, Kanazawa, Yuta, Tezuka, Masahiro, Takei, Yusuke, Tsuchiya, Go, Konishi, Taisuke, Shibasaki, Ikuko, Ogata, Koji, Monta, Osamu, Tsutsumi, Yasushi, Fukuda, Hirotsugu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9604414/
https://www.ncbi.nlm.nih.gov/pubmed/36286307
http://dx.doi.org/10.3390/jcdd9100355
_version_ 1784817808306077696
author Saito, Shunsuke
Sairenchi, Toshimi
Hirota, Shotaro
Niitsuma, Ken
Yokoyama, Shohei
Kanno, Yasuyuki
Kanazawa, Yuta
Tezuka, Masahiro
Takei, Yusuke
Tsuchiya, Go
Konishi, Taisuke
Shibasaki, Ikuko
Ogata, Koji
Monta, Osamu
Tsutsumi, Yasushi
Fukuda, Hirotsugu
author_facet Saito, Shunsuke
Sairenchi, Toshimi
Hirota, Shotaro
Niitsuma, Ken
Yokoyama, Shohei
Kanno, Yasuyuki
Kanazawa, Yuta
Tezuka, Masahiro
Takei, Yusuke
Tsuchiya, Go
Konishi, Taisuke
Shibasaki, Ikuko
Ogata, Koji
Monta, Osamu
Tsutsumi, Yasushi
Fukuda, Hirotsugu
author_sort Saito, Shunsuke
collection PubMed
description Background This study compared the clinical outcomes of transcatheter (TAVR) and surgical (SAVR) aortic valve replacements, focusing on postoperative valvular performance assessed by echocardiography. Method and Results A total of 425 patients who underwent TAVR (230 patients) or SAVR (195 patients) were included. Postoperative effective orifice area index (EOAI) was higher in the TAVR group (1.27 ± 0.35 cm(2)/m(2)) than in the SAVR group (1.06 ± 0.27 cm(2)/m(2), p < 0.001), and patient–prosthesis mismatch (PPM) was more frequent in the SAVR group (22.6%) than in the TAVR group (8.7%, p < 0.001). Mild or greater paravalvular leakage (PVL) was more frequent in the TAVR group (21.3%) than in the SAVR group (0%, p < 0.001). Moreover, there was no difference in freedom from all-cause death, stroke, or rehospitalization between the groups. Patients with moderate or greater PPM (EOAI < 0.85 cm(2)/m(2)) had lower freedom from composite events than those without this PPM criterion (p = 0.008). Patients with mild or greater PVL also had lower freedom from composite events than those without this PVL criterion (p = 0.017). Conclusions Postoperative valvular performance of TAVR was superior to that of SAVR in terms of EOAI. This merit was counterbalanced by the significantly lower rates of PVL in patients who underwent SAVR. The overall clinical outcomes were similar between the study groups.
format Online
Article
Text
id pubmed-9604414
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96044142022-10-27 Prosthetic Valve Function after Aortic Valve Replacement for Severe Aortic Stenosis by Transcatheter Procedure versus Surgery Saito, Shunsuke Sairenchi, Toshimi Hirota, Shotaro Niitsuma, Ken Yokoyama, Shohei Kanno, Yasuyuki Kanazawa, Yuta Tezuka, Masahiro Takei, Yusuke Tsuchiya, Go Konishi, Taisuke Shibasaki, Ikuko Ogata, Koji Monta, Osamu Tsutsumi, Yasushi Fukuda, Hirotsugu J Cardiovasc Dev Dis Article Background This study compared the clinical outcomes of transcatheter (TAVR) and surgical (SAVR) aortic valve replacements, focusing on postoperative valvular performance assessed by echocardiography. Method and Results A total of 425 patients who underwent TAVR (230 patients) or SAVR (195 patients) were included. Postoperative effective orifice area index (EOAI) was higher in the TAVR group (1.27 ± 0.35 cm(2)/m(2)) than in the SAVR group (1.06 ± 0.27 cm(2)/m(2), p < 0.001), and patient–prosthesis mismatch (PPM) was more frequent in the SAVR group (22.6%) than in the TAVR group (8.7%, p < 0.001). Mild or greater paravalvular leakage (PVL) was more frequent in the TAVR group (21.3%) than in the SAVR group (0%, p < 0.001). Moreover, there was no difference in freedom from all-cause death, stroke, or rehospitalization between the groups. Patients with moderate or greater PPM (EOAI < 0.85 cm(2)/m(2)) had lower freedom from composite events than those without this PPM criterion (p = 0.008). Patients with mild or greater PVL also had lower freedom from composite events than those without this PVL criterion (p = 0.017). Conclusions Postoperative valvular performance of TAVR was superior to that of SAVR in terms of EOAI. This merit was counterbalanced by the significantly lower rates of PVL in patients who underwent SAVR. The overall clinical outcomes were similar between the study groups. MDPI 2022-10-16 /pmc/articles/PMC9604414/ /pubmed/36286307 http://dx.doi.org/10.3390/jcdd9100355 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Saito, Shunsuke
Sairenchi, Toshimi
Hirota, Shotaro
Niitsuma, Ken
Yokoyama, Shohei
Kanno, Yasuyuki
Kanazawa, Yuta
Tezuka, Masahiro
Takei, Yusuke
Tsuchiya, Go
Konishi, Taisuke
Shibasaki, Ikuko
Ogata, Koji
Monta, Osamu
Tsutsumi, Yasushi
Fukuda, Hirotsugu
Prosthetic Valve Function after Aortic Valve Replacement for Severe Aortic Stenosis by Transcatheter Procedure versus Surgery
title Prosthetic Valve Function after Aortic Valve Replacement for Severe Aortic Stenosis by Transcatheter Procedure versus Surgery
title_full Prosthetic Valve Function after Aortic Valve Replacement for Severe Aortic Stenosis by Transcatheter Procedure versus Surgery
title_fullStr Prosthetic Valve Function after Aortic Valve Replacement for Severe Aortic Stenosis by Transcatheter Procedure versus Surgery
title_full_unstemmed Prosthetic Valve Function after Aortic Valve Replacement for Severe Aortic Stenosis by Transcatheter Procedure versus Surgery
title_short Prosthetic Valve Function after Aortic Valve Replacement for Severe Aortic Stenosis by Transcatheter Procedure versus Surgery
title_sort prosthetic valve function after aortic valve replacement for severe aortic stenosis by transcatheter procedure versus surgery
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9604414/
https://www.ncbi.nlm.nih.gov/pubmed/36286307
http://dx.doi.org/10.3390/jcdd9100355
work_keys_str_mv AT saitoshunsuke prostheticvalvefunctionafteraorticvalvereplacementforsevereaorticstenosisbytranscatheterprocedureversussurgery
AT sairenchitoshimi prostheticvalvefunctionafteraorticvalvereplacementforsevereaorticstenosisbytranscatheterprocedureversussurgery
AT hirotashotaro prostheticvalvefunctionafteraorticvalvereplacementforsevereaorticstenosisbytranscatheterprocedureversussurgery
AT niitsumaken prostheticvalvefunctionafteraorticvalvereplacementforsevereaorticstenosisbytranscatheterprocedureversussurgery
AT yokoyamashohei prostheticvalvefunctionafteraorticvalvereplacementforsevereaorticstenosisbytranscatheterprocedureversussurgery
AT kannoyasuyuki prostheticvalvefunctionafteraorticvalvereplacementforsevereaorticstenosisbytranscatheterprocedureversussurgery
AT kanazawayuta prostheticvalvefunctionafteraorticvalvereplacementforsevereaorticstenosisbytranscatheterprocedureversussurgery
AT tezukamasahiro prostheticvalvefunctionafteraorticvalvereplacementforsevereaorticstenosisbytranscatheterprocedureversussurgery
AT takeiyusuke prostheticvalvefunctionafteraorticvalvereplacementforsevereaorticstenosisbytranscatheterprocedureversussurgery
AT tsuchiyago prostheticvalvefunctionafteraorticvalvereplacementforsevereaorticstenosisbytranscatheterprocedureversussurgery
AT konishitaisuke prostheticvalvefunctionafteraorticvalvereplacementforsevereaorticstenosisbytranscatheterprocedureversussurgery
AT shibasakiikuko prostheticvalvefunctionafteraorticvalvereplacementforsevereaorticstenosisbytranscatheterprocedureversussurgery
AT ogatakoji prostheticvalvefunctionafteraorticvalvereplacementforsevereaorticstenosisbytranscatheterprocedureversussurgery
AT montaosamu prostheticvalvefunctionafteraorticvalvereplacementforsevereaorticstenosisbytranscatheterprocedureversussurgery
AT tsutsumiyasushi prostheticvalvefunctionafteraorticvalvereplacementforsevereaorticstenosisbytranscatheterprocedureversussurgery
AT fukudahirotsugu prostheticvalvefunctionafteraorticvalvereplacementforsevereaorticstenosisbytranscatheterprocedureversussurgery