Cargando…

Post-Implant Phosphodiesterase-5 Inhibitors in Patients with Left Ventricular Assist Device: A Systematic Review and Meta-Analysis

Background: Despite the improvement in left ventricular assist device (LVAD) technology and the advent of third-generation LVADs, hemocompatibility-related events remain a significant issue. Therefore, new pharmacological treatments are necessary to optimize patient management and to further reduce...

Descripción completa

Detalles Bibliográficos
Autores principales: Xanthopoulos, Andrew, Magouliotis, Dimitrios E., Tryposkiadis, Konstantinos, Zotos, Prokopis-Andreas, Spiliopoulos, Kyriakos, Athanasiou, Thanos, Giamouzis, Grigorios, Skoularigis, John, Starling, Randall C., Triposkiadis, Filippos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9604415/
https://www.ncbi.nlm.nih.gov/pubmed/36294308
http://dx.doi.org/10.3390/jcm11205988
Descripción
Sumario:Background: Despite the improvement in left ventricular assist device (LVAD) technology and the advent of third-generation LVADs, hemocompatibility-related events remain a significant issue. Therefore, new pharmacological treatments are necessary to optimize patient management and to further reduce hemocompatibility-related events. The purpose of the present systematic review and meta-analysis was to summarize the existing data regarding the safety and efficacy of post-implant phosphodiesterase-5 inhibitors (PDE-5i) on hemocompatibility-related events. Methods: Among the 258 articles in Pubmed, Scopus, and CENTRAL that were retrieved (1990–2022), 15 studies were included in the qualitative synthesis, and 9 studies were included in the quantitative synthesis. The fixed-effects model was used because it is statistically sound for combining a very small number of studies. The primary endpoint of the study was all-cause mortality, whereas the secondary endpoints were ischemic stroke, pump thrombosis, and gastrointestinal bleeding. Results: Mortality was significantly lower in the PDE-5i group vs. the control group (OR: 0.92 [95% CI: 0.85, 0.98]; p = 0.02). The secondary endpoints ischemic stroke (OR: 0.87 [95% CI: 0.78, 0.98]; p = 0.02) and pump thrombosis (OR: 0.90 [95% CI: 0.82, 0.99]; p = 0.04) were also lower in the PDE-5i group. The incidence of gastrointestinal bleeding was significantly higher in patients with LVAD receiving PDE-5i (OR: 1.26 [95% CI: 1.11, 1.44]; p < 0.01). In the overall analysis, the heterogeneity of outcomes was low, except for pump thrombosis. Conclusions: The use of PDE-5i post-implant was associated with lower mortality and thrombotic events but with a higher risk of gastrointestinal bleeding.