Cargando…

Wound Infections in Adult Patients after Berlin Heart(®) EXCOR Biventricular Assist Device Implantation

SIMPLE SUMMARY: Our study shows that the Berlin Heart(®) EXCOR as a biventricular assist device in adult patients is an effective strategy in heart failure medicine. Our results may increase the use of the EXCOR with acceptable clinical outcomes despite long support times. With ongoing research to i...

Descripción completa

Detalles Bibliográficos
Autores principales: Kremer, Jamila, El-Dor, Abbas, Rivinius, Rasmus, Schlegel, Philipp, Sommer, Wiebke, Warnecke, Gregor, Karck, Matthias, Ruhparwar, Arjang, Meyer, Anna L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9604684/
https://www.ncbi.nlm.nih.gov/pubmed/36294985
http://dx.doi.org/10.3390/life12101550
_version_ 1784817876306231296
author Kremer, Jamila
El-Dor, Abbas
Rivinius, Rasmus
Schlegel, Philipp
Sommer, Wiebke
Warnecke, Gregor
Karck, Matthias
Ruhparwar, Arjang
Meyer, Anna L.
author_facet Kremer, Jamila
El-Dor, Abbas
Rivinius, Rasmus
Schlegel, Philipp
Sommer, Wiebke
Warnecke, Gregor
Karck, Matthias
Ruhparwar, Arjang
Meyer, Anna L.
author_sort Kremer, Jamila
collection PubMed
description SIMPLE SUMMARY: Our study shows that the Berlin Heart(®) EXCOR as a biventricular assist device in adult patients is an effective strategy in heart failure medicine. Our results may increase the use of the EXCOR with acceptable clinical outcomes despite long support times. With ongoing research to implement the EXCOR as a permanent right ventricular assist device, our results highlight possible arising complications. ABSTRACT: The Berlin Heart(®) EXCOR is a paracorporeal, pulsatile ventricular assist device used in patients of all age groups. However, adolescent and adult patients on EXCOR support are scarcely explored. Herein, we present a detailed description of infectious complications in this patient cohort. From 2006 to 2020, 58 patients received a biventricular assist device (BiVAD) at our institution and were included in this study. Postoperative infections were assessed after BiVAD implantation and subsequent heart transplantation (HTx). A Berlin Heart(®) EXCOR BiVAD was implanted as a bridge to transplantation in 58 patients (12–64 years). Most patients were INTERMACS I, and their median age was 49 years. Wound infections (WI) specific to the ventricular assist device (VAD) occurred in 31 (53.4%) patients with a mean time of 113 ± 155 days after BiVAD implantation. HTx was performed in 30 (51.7%) patients and thereof 10 (33.3%) patients developed at least one WI post-HTx. The mean time of WI after HTx was 17 ± 14 days. In four cases, WIs were caused by the same pathogen as before HTx. According to our institutional BiVAD wound classification, the mean wound score was 3. The VAD-specific wound infections were manageable and did not increase mortality nor precluded HTx in Berlin Heart(®) EXCOR patients. No specific risk factors for VAD-specific wound infections could be identified.
format Online
Article
Text
id pubmed-9604684
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96046842022-10-27 Wound Infections in Adult Patients after Berlin Heart(®) EXCOR Biventricular Assist Device Implantation Kremer, Jamila El-Dor, Abbas Rivinius, Rasmus Schlegel, Philipp Sommer, Wiebke Warnecke, Gregor Karck, Matthias Ruhparwar, Arjang Meyer, Anna L. Life (Basel) Article SIMPLE SUMMARY: Our study shows that the Berlin Heart(®) EXCOR as a biventricular assist device in adult patients is an effective strategy in heart failure medicine. Our results may increase the use of the EXCOR with acceptable clinical outcomes despite long support times. With ongoing research to implement the EXCOR as a permanent right ventricular assist device, our results highlight possible arising complications. ABSTRACT: The Berlin Heart(®) EXCOR is a paracorporeal, pulsatile ventricular assist device used in patients of all age groups. However, adolescent and adult patients on EXCOR support are scarcely explored. Herein, we present a detailed description of infectious complications in this patient cohort. From 2006 to 2020, 58 patients received a biventricular assist device (BiVAD) at our institution and were included in this study. Postoperative infections were assessed after BiVAD implantation and subsequent heart transplantation (HTx). A Berlin Heart(®) EXCOR BiVAD was implanted as a bridge to transplantation in 58 patients (12–64 years). Most patients were INTERMACS I, and their median age was 49 years. Wound infections (WI) specific to the ventricular assist device (VAD) occurred in 31 (53.4%) patients with a mean time of 113 ± 155 days after BiVAD implantation. HTx was performed in 30 (51.7%) patients and thereof 10 (33.3%) patients developed at least one WI post-HTx. The mean time of WI after HTx was 17 ± 14 days. In four cases, WIs were caused by the same pathogen as before HTx. According to our institutional BiVAD wound classification, the mean wound score was 3. The VAD-specific wound infections were manageable and did not increase mortality nor precluded HTx in Berlin Heart(®) EXCOR patients. No specific risk factors for VAD-specific wound infections could be identified. MDPI 2022-10-06 /pmc/articles/PMC9604684/ /pubmed/36294985 http://dx.doi.org/10.3390/life12101550 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kremer, Jamila
El-Dor, Abbas
Rivinius, Rasmus
Schlegel, Philipp
Sommer, Wiebke
Warnecke, Gregor
Karck, Matthias
Ruhparwar, Arjang
Meyer, Anna L.
Wound Infections in Adult Patients after Berlin Heart(®) EXCOR Biventricular Assist Device Implantation
title Wound Infections in Adult Patients after Berlin Heart(®) EXCOR Biventricular Assist Device Implantation
title_full Wound Infections in Adult Patients after Berlin Heart(®) EXCOR Biventricular Assist Device Implantation
title_fullStr Wound Infections in Adult Patients after Berlin Heart(®) EXCOR Biventricular Assist Device Implantation
title_full_unstemmed Wound Infections in Adult Patients after Berlin Heart(®) EXCOR Biventricular Assist Device Implantation
title_short Wound Infections in Adult Patients after Berlin Heart(®) EXCOR Biventricular Assist Device Implantation
title_sort wound infections in adult patients after berlin heart(®) excor biventricular assist device implantation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9604684/
https://www.ncbi.nlm.nih.gov/pubmed/36294985
http://dx.doi.org/10.3390/life12101550
work_keys_str_mv AT kremerjamila woundinfectionsinadultpatientsafterberlinheartexcorbiventricularassistdeviceimplantation
AT eldorabbas woundinfectionsinadultpatientsafterberlinheartexcorbiventricularassistdeviceimplantation
AT riviniusrasmus woundinfectionsinadultpatientsafterberlinheartexcorbiventricularassistdeviceimplantation
AT schlegelphilipp woundinfectionsinadultpatientsafterberlinheartexcorbiventricularassistdeviceimplantation
AT sommerwiebke woundinfectionsinadultpatientsafterberlinheartexcorbiventricularassistdeviceimplantation
AT warneckegregor woundinfectionsinadultpatientsafterberlinheartexcorbiventricularassistdeviceimplantation
AT karckmatthias woundinfectionsinadultpatientsafterberlinheartexcorbiventricularassistdeviceimplantation
AT ruhparwararjang woundinfectionsinadultpatientsafterberlinheartexcorbiventricularassistdeviceimplantation
AT meyerannal woundinfectionsinadultpatientsafterberlinheartexcorbiventricularassistdeviceimplantation