Cargando…

Mitral Valve Systolic Anterior Motion in Robotic Thoracic Surgery as the Cause of Unexplained Hemodynamic Shock: From a Case Report to Recommendations

Robotic major lung resection for lung cancer carries a risk for intraoperative hemodynamic instability. Systolic anterior motion (SAM) of the mitral valve is a rare and often misrecognized cause of intraoperative hemodynamic instability. If not promptly recognized, SAM leads to a complicated periope...

Descripción completa

Detalles Bibliográficos
Autores principales: Monaco, Fabrizio, D’Amico, Filippo, Barucco, Gaia, Licheri, Margherita, Novellis, Pierluigi, Ciriaco, Paola, Veronesi, Giulia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9604796/
https://www.ncbi.nlm.nih.gov/pubmed/36294365
http://dx.doi.org/10.3390/jcm11206044
_version_ 1784817904803381248
author Monaco, Fabrizio
D’Amico, Filippo
Barucco, Gaia
Licheri, Margherita
Novellis, Pierluigi
Ciriaco, Paola
Veronesi, Giulia
author_facet Monaco, Fabrizio
D’Amico, Filippo
Barucco, Gaia
Licheri, Margherita
Novellis, Pierluigi
Ciriaco, Paola
Veronesi, Giulia
author_sort Monaco, Fabrizio
collection PubMed
description Robotic major lung resection for lung cancer carries a risk for intraoperative hemodynamic instability. Systolic anterior motion (SAM) of the mitral valve is a rare and often misrecognized cause of intraoperative hemodynamic instability. If not promptly recognized, SAM leads to a complicated perioperative course. Here, we report for the first time a case of a patient with SAM with a severe degree of left ventricular outflow obstruction (LVOTO) undergoing robotic lung lobectomy and its challenging intraoperative management. A 70-year-old man undergoing robotic left upper lobectomy developed immediately after the induction of general anesthesia hemodynamic instability due to SAM-related LVOTO. The diagnosis was possible, thanks to the use of transesophageal echocardiography (TEE). The treatment strategies applied were preload optimization without fluid overload, ultra-short-acting beta-blockers, and vasopressors. Peripheral nerve blockades were preferred over epidural analgesia to avoid vasodilatation. The patient reported a good quality of recovery and no pain the day after surgery. The management of patients with higher risk of SAM and LVOTO development during robotic thoracic surgery requires a dedicated and skilled team together with high-impact treatment strategies driven by TEE. Since current guidelines do not recommend the use of TEE, even for patients with higher cardiac risk undergoing noncardiac surgery, the present case report may stimulate interest in future recommendations.
format Online
Article
Text
id pubmed-9604796
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96047962022-10-27 Mitral Valve Systolic Anterior Motion in Robotic Thoracic Surgery as the Cause of Unexplained Hemodynamic Shock: From a Case Report to Recommendations Monaco, Fabrizio D’Amico, Filippo Barucco, Gaia Licheri, Margherita Novellis, Pierluigi Ciriaco, Paola Veronesi, Giulia J Clin Med Case Report Robotic major lung resection for lung cancer carries a risk for intraoperative hemodynamic instability. Systolic anterior motion (SAM) of the mitral valve is a rare and often misrecognized cause of intraoperative hemodynamic instability. If not promptly recognized, SAM leads to a complicated perioperative course. Here, we report for the first time a case of a patient with SAM with a severe degree of left ventricular outflow obstruction (LVOTO) undergoing robotic lung lobectomy and its challenging intraoperative management. A 70-year-old man undergoing robotic left upper lobectomy developed immediately after the induction of general anesthesia hemodynamic instability due to SAM-related LVOTO. The diagnosis was possible, thanks to the use of transesophageal echocardiography (TEE). The treatment strategies applied were preload optimization without fluid overload, ultra-short-acting beta-blockers, and vasopressors. Peripheral nerve blockades were preferred over epidural analgesia to avoid vasodilatation. The patient reported a good quality of recovery and no pain the day after surgery. The management of patients with higher risk of SAM and LVOTO development during robotic thoracic surgery requires a dedicated and skilled team together with high-impact treatment strategies driven by TEE. Since current guidelines do not recommend the use of TEE, even for patients with higher cardiac risk undergoing noncardiac surgery, the present case report may stimulate interest in future recommendations. MDPI 2022-10-13 /pmc/articles/PMC9604796/ /pubmed/36294365 http://dx.doi.org/10.3390/jcm11206044 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Case Report
Monaco, Fabrizio
D’Amico, Filippo
Barucco, Gaia
Licheri, Margherita
Novellis, Pierluigi
Ciriaco, Paola
Veronesi, Giulia
Mitral Valve Systolic Anterior Motion in Robotic Thoracic Surgery as the Cause of Unexplained Hemodynamic Shock: From a Case Report to Recommendations
title Mitral Valve Systolic Anterior Motion in Robotic Thoracic Surgery as the Cause of Unexplained Hemodynamic Shock: From a Case Report to Recommendations
title_full Mitral Valve Systolic Anterior Motion in Robotic Thoracic Surgery as the Cause of Unexplained Hemodynamic Shock: From a Case Report to Recommendations
title_fullStr Mitral Valve Systolic Anterior Motion in Robotic Thoracic Surgery as the Cause of Unexplained Hemodynamic Shock: From a Case Report to Recommendations
title_full_unstemmed Mitral Valve Systolic Anterior Motion in Robotic Thoracic Surgery as the Cause of Unexplained Hemodynamic Shock: From a Case Report to Recommendations
title_short Mitral Valve Systolic Anterior Motion in Robotic Thoracic Surgery as the Cause of Unexplained Hemodynamic Shock: From a Case Report to Recommendations
title_sort mitral valve systolic anterior motion in robotic thoracic surgery as the cause of unexplained hemodynamic shock: from a case report to recommendations
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9604796/
https://www.ncbi.nlm.nih.gov/pubmed/36294365
http://dx.doi.org/10.3390/jcm11206044
work_keys_str_mv AT monacofabrizio mitralvalvesystolicanteriormotioninroboticthoracicsurgeryasthecauseofunexplainedhemodynamicshockfromacasereporttorecommendations
AT damicofilippo mitralvalvesystolicanteriormotioninroboticthoracicsurgeryasthecauseofunexplainedhemodynamicshockfromacasereporttorecommendations
AT baruccogaia mitralvalvesystolicanteriormotioninroboticthoracicsurgeryasthecauseofunexplainedhemodynamicshockfromacasereporttorecommendations
AT licherimargherita mitralvalvesystolicanteriormotioninroboticthoracicsurgeryasthecauseofunexplainedhemodynamicshockfromacasereporttorecommendations
AT novellispierluigi mitralvalvesystolicanteriormotioninroboticthoracicsurgeryasthecauseofunexplainedhemodynamicshockfromacasereporttorecommendations
AT ciriacopaola mitralvalvesystolicanteriormotioninroboticthoracicsurgeryasthecauseofunexplainedhemodynamicshockfromacasereporttorecommendations
AT veronesigiulia mitralvalvesystolicanteriormotioninroboticthoracicsurgeryasthecauseofunexplainedhemodynamicshockfromacasereporttorecommendations