Cargando…

Mechanical Performance Study of Beam–Column Connection with U-Shaped Steel Damper

The article proposes the use of a semi-rigid energy-dissipation connection combined with a U-shaped metal damper to avoid brittle failure of rigid steel beam–column connections under seismic loading. The U-shaped metal damper connects the H-section column and the H-section beam to form a new energy-...

Descripción completa

Detalles Bibliográficos
Autores principales: Qu, Chun-Xu, Xu, Yu-Wen, Gao, Jin-He, Zhou, Wei-Hao, Zheng, Bao-Zhu, Li, Peng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9605227/
https://www.ncbi.nlm.nih.gov/pubmed/36295152
http://dx.doi.org/10.3390/ma15207085
_version_ 1784818013770350592
author Qu, Chun-Xu
Xu, Yu-Wen
Gao, Jin-He
Zhou, Wei-Hao
Zheng, Bao-Zhu
Li, Peng
author_facet Qu, Chun-Xu
Xu, Yu-Wen
Gao, Jin-He
Zhou, Wei-Hao
Zheng, Bao-Zhu
Li, Peng
author_sort Qu, Chun-Xu
collection PubMed
description The article proposes the use of a semi-rigid energy-dissipation connection combined with a U-shaped metal damper to avoid brittle failure of rigid steel beam–column connections under seismic loading. The U-shaped metal damper connects the H-section column and the H-section beam to form a new energy-dissipation connection as an energy-dissipation member. Compared with the existing research, this connection has a stable energy-dissipation performance and great ductility. To clarify the mechanism of energy dissipation, mechanical models under two U-shaped damping deformation modes are established. The calculation formulas for the yield load and stiffness are derived for the corresponding deformation mode using the unit load method. Taking the T-shaped beam–column connection and the application of U-shaped steel damper in the beam–column connection as an example, the mechanical model of the connection is established and the calculation formulas for the yield load and stiffness are derived. At the same time, the connection is subjected to a quasi-static test under cyclic loading. The results show that the hysteretic curve of the test is complete and that the skeleton curve is accurate compared to the theory. The error range of the initial stiffness and yield load obtained by the test and the theoretical formula is kept within 20%, indicating that the theoretical formula is reasonable and feasible. In addition, the correctness of the finite element model is verified by establishing a finite element model and comparing it with the test. The mechanical responses of purely rigid connections and rigid semi-rigid composite connections are compared and analyzed using a multi-story and multi-span plane frame as an example. The results show that the model with semi-rigid connections, compared to the model with rigid connections, avoids the gradual loss of bearing capacity caused by the failure of the connection area of the second floor of the main structure and improves the seismic performance of the main structure.
format Online
Article
Text
id pubmed-9605227
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96052272022-10-27 Mechanical Performance Study of Beam–Column Connection with U-Shaped Steel Damper Qu, Chun-Xu Xu, Yu-Wen Gao, Jin-He Zhou, Wei-Hao Zheng, Bao-Zhu Li, Peng Materials (Basel) Article The article proposes the use of a semi-rigid energy-dissipation connection combined with a U-shaped metal damper to avoid brittle failure of rigid steel beam–column connections under seismic loading. The U-shaped metal damper connects the H-section column and the H-section beam to form a new energy-dissipation connection as an energy-dissipation member. Compared with the existing research, this connection has a stable energy-dissipation performance and great ductility. To clarify the mechanism of energy dissipation, mechanical models under two U-shaped damping deformation modes are established. The calculation formulas for the yield load and stiffness are derived for the corresponding deformation mode using the unit load method. Taking the T-shaped beam–column connection and the application of U-shaped steel damper in the beam–column connection as an example, the mechanical model of the connection is established and the calculation formulas for the yield load and stiffness are derived. At the same time, the connection is subjected to a quasi-static test under cyclic loading. The results show that the hysteretic curve of the test is complete and that the skeleton curve is accurate compared to the theory. The error range of the initial stiffness and yield load obtained by the test and the theoretical formula is kept within 20%, indicating that the theoretical formula is reasonable and feasible. In addition, the correctness of the finite element model is verified by establishing a finite element model and comparing it with the test. The mechanical responses of purely rigid connections and rigid semi-rigid composite connections are compared and analyzed using a multi-story and multi-span plane frame as an example. The results show that the model with semi-rigid connections, compared to the model with rigid connections, avoids the gradual loss of bearing capacity caused by the failure of the connection area of the second floor of the main structure and improves the seismic performance of the main structure. MDPI 2022-10-12 /pmc/articles/PMC9605227/ /pubmed/36295152 http://dx.doi.org/10.3390/ma15207085 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Qu, Chun-Xu
Xu, Yu-Wen
Gao, Jin-He
Zhou, Wei-Hao
Zheng, Bao-Zhu
Li, Peng
Mechanical Performance Study of Beam–Column Connection with U-Shaped Steel Damper
title Mechanical Performance Study of Beam–Column Connection with U-Shaped Steel Damper
title_full Mechanical Performance Study of Beam–Column Connection with U-Shaped Steel Damper
title_fullStr Mechanical Performance Study of Beam–Column Connection with U-Shaped Steel Damper
title_full_unstemmed Mechanical Performance Study of Beam–Column Connection with U-Shaped Steel Damper
title_short Mechanical Performance Study of Beam–Column Connection with U-Shaped Steel Damper
title_sort mechanical performance study of beam–column connection with u-shaped steel damper
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9605227/
https://www.ncbi.nlm.nih.gov/pubmed/36295152
http://dx.doi.org/10.3390/ma15207085
work_keys_str_mv AT quchunxu mechanicalperformancestudyofbeamcolumnconnectionwithushapedsteeldamper
AT xuyuwen mechanicalperformancestudyofbeamcolumnconnectionwithushapedsteeldamper
AT gaojinhe mechanicalperformancestudyofbeamcolumnconnectionwithushapedsteeldamper
AT zhouweihao mechanicalperformancestudyofbeamcolumnconnectionwithushapedsteeldamper
AT zhengbaozhu mechanicalperformancestudyofbeamcolumnconnectionwithushapedsteeldamper
AT lipeng mechanicalperformancestudyofbeamcolumnconnectionwithushapedsteeldamper