Cargando…

Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study

(1) Background: Previous studies reported limited performance of arterial pressure waveform-based cardiac output (CO) estimation (FloTrac/Vigileo system; CO-FloTrac) compared with the intermittent thermodilution technique (CO(int)). However, errors due to bolus maneuver and intermittent measurements...

Descripción completa

Detalles Bibliográficos
Autores principales: Oh, Chahyun, Lee, Soomin, Oh, Pyeonghwa, Chung, Woosuk, Ko, Youngkwon, Yoon, Seok-Hwa, Kim, Yoon-Hee, Ji, Sung-Mi, Hong, Boohwi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9605331/
https://www.ncbi.nlm.nih.gov/pubmed/36294414
http://dx.doi.org/10.3390/jcm11206093
_version_ 1784818040451366912
author Oh, Chahyun
Lee, Soomin
Oh, Pyeonghwa
Chung, Woosuk
Ko, Youngkwon
Yoon, Seok-Hwa
Kim, Yoon-Hee
Ji, Sung-Mi
Hong, Boohwi
author_facet Oh, Chahyun
Lee, Soomin
Oh, Pyeonghwa
Chung, Woosuk
Ko, Youngkwon
Yoon, Seok-Hwa
Kim, Yoon-Hee
Ji, Sung-Mi
Hong, Boohwi
author_sort Oh, Chahyun
collection PubMed
description (1) Background: Previous studies reported limited performance of arterial pressure waveform-based cardiac output (CO) estimation (FloTrac/Vigileo system; CO-FloTrac) compared with the intermittent thermodilution technique (CO(int)). However, errors due to bolus maneuver and intermittent measurements of CO(int) could limit its use as a reference. The continuous thermodilution technique (CO(cont)) may relieve such limitations. (2) Methods: The performance of CO-FloTrac was retrospectively assessed using continuous recordings of intraoperative physiological data acquired from patients who underwent off-pump coronary artery bypass graft (OPCAB) surgery with CO monitoring using both CO-FloTrac and CO(cont). Optimal time adjustments between the two measurements were determined based on R-squared values. (3) Results: A total of 134.2 h of data from 30 patients was included in the final analysis. The mean bias was –0.94 (95% CI, −1.35 to −0.52) L/min and the limits of agreements were −3.64 (95% CI, −4.44 to −3.08) L/min and 1.77 (95% CI, 1.21 to 2.57) L/min. The percentage error was 66.1% (95% CI, 52.4 to 85.8%). Depending on the time scale and the size of the exclusion zone, concordance rates ranged from 61.0% to 75.0%. (4) Conclusion: Despite the time adjustments, CO-FloTrac showed non-negligible overestimation, clinically unacceptable precision, and poor trending ability during OPCAB surgery.
format Online
Article
Text
id pubmed-9605331
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96053312022-10-27 Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study Oh, Chahyun Lee, Soomin Oh, Pyeonghwa Chung, Woosuk Ko, Youngkwon Yoon, Seok-Hwa Kim, Yoon-Hee Ji, Sung-Mi Hong, Boohwi J Clin Med Article (1) Background: Previous studies reported limited performance of arterial pressure waveform-based cardiac output (CO) estimation (FloTrac/Vigileo system; CO-FloTrac) compared with the intermittent thermodilution technique (CO(int)). However, errors due to bolus maneuver and intermittent measurements of CO(int) could limit its use as a reference. The continuous thermodilution technique (CO(cont)) may relieve such limitations. (2) Methods: The performance of CO-FloTrac was retrospectively assessed using continuous recordings of intraoperative physiological data acquired from patients who underwent off-pump coronary artery bypass graft (OPCAB) surgery with CO monitoring using both CO-FloTrac and CO(cont). Optimal time adjustments between the two measurements were determined based on R-squared values. (3) Results: A total of 134.2 h of data from 30 patients was included in the final analysis. The mean bias was –0.94 (95% CI, −1.35 to −0.52) L/min and the limits of agreements were −3.64 (95% CI, −4.44 to −3.08) L/min and 1.77 (95% CI, 1.21 to 2.57) L/min. The percentage error was 66.1% (95% CI, 52.4 to 85.8%). Depending on the time scale and the size of the exclusion zone, concordance rates ranged from 61.0% to 75.0%. (4) Conclusion: Despite the time adjustments, CO-FloTrac showed non-negligible overestimation, clinically unacceptable precision, and poor trending ability during OPCAB surgery. MDPI 2022-10-16 /pmc/articles/PMC9605331/ /pubmed/36294414 http://dx.doi.org/10.3390/jcm11206093 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Oh, Chahyun
Lee, Soomin
Oh, Pyeonghwa
Chung, Woosuk
Ko, Youngkwon
Yoon, Seok-Hwa
Kim, Yoon-Hee
Ji, Sung-Mi
Hong, Boohwi
Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study
title Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study
title_full Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study
title_fullStr Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study
title_full_unstemmed Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study
title_short Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study
title_sort comparison between fourth-generation flotrac/vigileo system and continuous thermodilution technique for cardiac output estimation after time adjustment during off-pump coronary artery bypass graft surgery: a retrospective cohort study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9605331/
https://www.ncbi.nlm.nih.gov/pubmed/36294414
http://dx.doi.org/10.3390/jcm11206093
work_keys_str_mv AT ohchahyun comparisonbetweenfourthgenerationflotracvigileosystemandcontinuousthermodilutiontechniqueforcardiacoutputestimationaftertimeadjustmentduringoffpumpcoronaryarterybypassgraftsurgeryaretrospectivecohortstudy
AT leesoomin comparisonbetweenfourthgenerationflotracvigileosystemandcontinuousthermodilutiontechniqueforcardiacoutputestimationaftertimeadjustmentduringoffpumpcoronaryarterybypassgraftsurgeryaretrospectivecohortstudy
AT ohpyeonghwa comparisonbetweenfourthgenerationflotracvigileosystemandcontinuousthermodilutiontechniqueforcardiacoutputestimationaftertimeadjustmentduringoffpumpcoronaryarterybypassgraftsurgeryaretrospectivecohortstudy
AT chungwoosuk comparisonbetweenfourthgenerationflotracvigileosystemandcontinuousthermodilutiontechniqueforcardiacoutputestimationaftertimeadjustmentduringoffpumpcoronaryarterybypassgraftsurgeryaretrospectivecohortstudy
AT koyoungkwon comparisonbetweenfourthgenerationflotracvigileosystemandcontinuousthermodilutiontechniqueforcardiacoutputestimationaftertimeadjustmentduringoffpumpcoronaryarterybypassgraftsurgeryaretrospectivecohortstudy
AT yoonseokhwa comparisonbetweenfourthgenerationflotracvigileosystemandcontinuousthermodilutiontechniqueforcardiacoutputestimationaftertimeadjustmentduringoffpumpcoronaryarterybypassgraftsurgeryaretrospectivecohortstudy
AT kimyoonhee comparisonbetweenfourthgenerationflotracvigileosystemandcontinuousthermodilutiontechniqueforcardiacoutputestimationaftertimeadjustmentduringoffpumpcoronaryarterybypassgraftsurgeryaretrospectivecohortstudy
AT jisungmi comparisonbetweenfourthgenerationflotracvigileosystemandcontinuousthermodilutiontechniqueforcardiacoutputestimationaftertimeadjustmentduringoffpumpcoronaryarterybypassgraftsurgeryaretrospectivecohortstudy
AT hongboohwi comparisonbetweenfourthgenerationflotracvigileosystemandcontinuousthermodilutiontechniqueforcardiacoutputestimationaftertimeadjustmentduringoffpumpcoronaryarterybypassgraftsurgeryaretrospectivecohortstudy