Cargando…
Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study
(1) Background: Previous studies reported limited performance of arterial pressure waveform-based cardiac output (CO) estimation (FloTrac/Vigileo system; CO-FloTrac) compared with the intermittent thermodilution technique (CO(int)). However, errors due to bolus maneuver and intermittent measurements...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9605331/ https://www.ncbi.nlm.nih.gov/pubmed/36294414 http://dx.doi.org/10.3390/jcm11206093 |
_version_ | 1784818040451366912 |
---|---|
author | Oh, Chahyun Lee, Soomin Oh, Pyeonghwa Chung, Woosuk Ko, Youngkwon Yoon, Seok-Hwa Kim, Yoon-Hee Ji, Sung-Mi Hong, Boohwi |
author_facet | Oh, Chahyun Lee, Soomin Oh, Pyeonghwa Chung, Woosuk Ko, Youngkwon Yoon, Seok-Hwa Kim, Yoon-Hee Ji, Sung-Mi Hong, Boohwi |
author_sort | Oh, Chahyun |
collection | PubMed |
description | (1) Background: Previous studies reported limited performance of arterial pressure waveform-based cardiac output (CO) estimation (FloTrac/Vigileo system; CO-FloTrac) compared with the intermittent thermodilution technique (CO(int)). However, errors due to bolus maneuver and intermittent measurements of CO(int) could limit its use as a reference. The continuous thermodilution technique (CO(cont)) may relieve such limitations. (2) Methods: The performance of CO-FloTrac was retrospectively assessed using continuous recordings of intraoperative physiological data acquired from patients who underwent off-pump coronary artery bypass graft (OPCAB) surgery with CO monitoring using both CO-FloTrac and CO(cont). Optimal time adjustments between the two measurements were determined based on R-squared values. (3) Results: A total of 134.2 h of data from 30 patients was included in the final analysis. The mean bias was –0.94 (95% CI, −1.35 to −0.52) L/min and the limits of agreements were −3.64 (95% CI, −4.44 to −3.08) L/min and 1.77 (95% CI, 1.21 to 2.57) L/min. The percentage error was 66.1% (95% CI, 52.4 to 85.8%). Depending on the time scale and the size of the exclusion zone, concordance rates ranged from 61.0% to 75.0%. (4) Conclusion: Despite the time adjustments, CO-FloTrac showed non-negligible overestimation, clinically unacceptable precision, and poor trending ability during OPCAB surgery. |
format | Online Article Text |
id | pubmed-9605331 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96053312022-10-27 Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study Oh, Chahyun Lee, Soomin Oh, Pyeonghwa Chung, Woosuk Ko, Youngkwon Yoon, Seok-Hwa Kim, Yoon-Hee Ji, Sung-Mi Hong, Boohwi J Clin Med Article (1) Background: Previous studies reported limited performance of arterial pressure waveform-based cardiac output (CO) estimation (FloTrac/Vigileo system; CO-FloTrac) compared with the intermittent thermodilution technique (CO(int)). However, errors due to bolus maneuver and intermittent measurements of CO(int) could limit its use as a reference. The continuous thermodilution technique (CO(cont)) may relieve such limitations. (2) Methods: The performance of CO-FloTrac was retrospectively assessed using continuous recordings of intraoperative physiological data acquired from patients who underwent off-pump coronary artery bypass graft (OPCAB) surgery with CO monitoring using both CO-FloTrac and CO(cont). Optimal time adjustments between the two measurements were determined based on R-squared values. (3) Results: A total of 134.2 h of data from 30 patients was included in the final analysis. The mean bias was –0.94 (95% CI, −1.35 to −0.52) L/min and the limits of agreements were −3.64 (95% CI, −4.44 to −3.08) L/min and 1.77 (95% CI, 1.21 to 2.57) L/min. The percentage error was 66.1% (95% CI, 52.4 to 85.8%). Depending on the time scale and the size of the exclusion zone, concordance rates ranged from 61.0% to 75.0%. (4) Conclusion: Despite the time adjustments, CO-FloTrac showed non-negligible overestimation, clinically unacceptable precision, and poor trending ability during OPCAB surgery. MDPI 2022-10-16 /pmc/articles/PMC9605331/ /pubmed/36294414 http://dx.doi.org/10.3390/jcm11206093 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Oh, Chahyun Lee, Soomin Oh, Pyeonghwa Chung, Woosuk Ko, Youngkwon Yoon, Seok-Hwa Kim, Yoon-Hee Ji, Sung-Mi Hong, Boohwi Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study |
title | Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study |
title_full | Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study |
title_fullStr | Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study |
title_full_unstemmed | Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study |
title_short | Comparison between Fourth-Generation FloTrac/Vigileo System and Continuous Thermodilution Technique for Cardiac Output Estimation after Time Adjustment during Off-Pump Coronary Artery Bypass Graft Surgery: A Retrospective Cohort Study |
title_sort | comparison between fourth-generation flotrac/vigileo system and continuous thermodilution technique for cardiac output estimation after time adjustment during off-pump coronary artery bypass graft surgery: a retrospective cohort study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9605331/ https://www.ncbi.nlm.nih.gov/pubmed/36294414 http://dx.doi.org/10.3390/jcm11206093 |
work_keys_str_mv | AT ohchahyun comparisonbetweenfourthgenerationflotracvigileosystemandcontinuousthermodilutiontechniqueforcardiacoutputestimationaftertimeadjustmentduringoffpumpcoronaryarterybypassgraftsurgeryaretrospectivecohortstudy AT leesoomin comparisonbetweenfourthgenerationflotracvigileosystemandcontinuousthermodilutiontechniqueforcardiacoutputestimationaftertimeadjustmentduringoffpumpcoronaryarterybypassgraftsurgeryaretrospectivecohortstudy AT ohpyeonghwa comparisonbetweenfourthgenerationflotracvigileosystemandcontinuousthermodilutiontechniqueforcardiacoutputestimationaftertimeadjustmentduringoffpumpcoronaryarterybypassgraftsurgeryaretrospectivecohortstudy AT chungwoosuk comparisonbetweenfourthgenerationflotracvigileosystemandcontinuousthermodilutiontechniqueforcardiacoutputestimationaftertimeadjustmentduringoffpumpcoronaryarterybypassgraftsurgeryaretrospectivecohortstudy AT koyoungkwon comparisonbetweenfourthgenerationflotracvigileosystemandcontinuousthermodilutiontechniqueforcardiacoutputestimationaftertimeadjustmentduringoffpumpcoronaryarterybypassgraftsurgeryaretrospectivecohortstudy AT yoonseokhwa comparisonbetweenfourthgenerationflotracvigileosystemandcontinuousthermodilutiontechniqueforcardiacoutputestimationaftertimeadjustmentduringoffpumpcoronaryarterybypassgraftsurgeryaretrospectivecohortstudy AT kimyoonhee comparisonbetweenfourthgenerationflotracvigileosystemandcontinuousthermodilutiontechniqueforcardiacoutputestimationaftertimeadjustmentduringoffpumpcoronaryarterybypassgraftsurgeryaretrospectivecohortstudy AT jisungmi comparisonbetweenfourthgenerationflotracvigileosystemandcontinuousthermodilutiontechniqueforcardiacoutputestimationaftertimeadjustmentduringoffpumpcoronaryarterybypassgraftsurgeryaretrospectivecohortstudy AT hongboohwi comparisonbetweenfourthgenerationflotracvigileosystemandcontinuousthermodilutiontechniqueforcardiacoutputestimationaftertimeadjustmentduringoffpumpcoronaryarterybypassgraftsurgeryaretrospectivecohortstudy |