Cargando…

Application of DSM–BIA in dry weight assessment in continuous ambulatory peritoneal dialysis

OBJECTIVES: Dry weight assessment (DWA) is an important part of dialysis and fluid management in patients receiving renal replacement therapy. With the development of bioimpedance analysis (BIA), the development of the direct segmental multi-frequency BIA (DSM–BIA) has provided a more convenient mea...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Qi, Wang, Zheng, Liu, Na, Mu, Shujuan, Guo, Peng, Li, Shichao, Zhou, Jingwei, Li, Yan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9605927/
https://www.ncbi.nlm.nih.gov/pubmed/35789973
http://dx.doi.org/10.1007/s11255-022-03281-7
_version_ 1784818184709210112
author Chen, Qi
Wang, Zheng
Liu, Na
Mu, Shujuan
Guo, Peng
Li, Shichao
Zhou, Jingwei
Li, Yan
author_facet Chen, Qi
Wang, Zheng
Liu, Na
Mu, Shujuan
Guo, Peng
Li, Shichao
Zhou, Jingwei
Li, Yan
author_sort Chen, Qi
collection PubMed
description OBJECTIVES: Dry weight assessment (DWA) is an important part of dialysis and fluid management in patients receiving renal replacement therapy. With the development of bioimpedance analysis (BIA), the development of the direct segmental multi-frequency BIA (DSM–BIA) has provided a more convenient measure for DWA of dialysis patients, but its accuracy remains unclear. This study was designed to evaluate the application of DSM–BIA in DWA of continuous ambulatory peritoneal dialysis (CAPD) patients. DESIGN: This is a cross-sectional study. Using the conventional BIA as a reference, we examined the accuracy of the DSM–BIA technique for assessing dry weight in CAPD patients and analyzed the potential factors influencing their fluid volume status. SETTING AND PARTICIPANTS: A total of 31 patients with end-stage renal disease receiving CAPD and 310 healthy volunteers were recruited for this study. METHODS: The intraclass correlation coefficients (ICC) and Bland–Altman plots were used to assess the consistency between DSM–BIA and the conventional BIA for DWA. Univariate and multivariate linear regression analyses were used to explore the influencing factors associated with the edema index. RESULTS: DSM–BIA and the conventional BIA technology were consistent in DWA in CAPD patients (ICC female 0.972, ICC male 0.882, ICC total 0.960). Similarly, Bland–Altman plots showed good agreements between the two methods in DWA for both genders. Univariate and multivariate linear regression analysis showed both eGFR level (P = 0.04) and serum NT-pro BNP concentration (P = 0.007) were positively correlated with the ratio of extracellular water to total body water (ECW/TCW). CONCLUSIONS: DSM–BIA in DWA has good accuracy in clinical applications and has potential application value for fluid volume management in CAPD patients. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11255-022-03281-7.
format Online
Article
Text
id pubmed-9605927
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-96059272022-10-28 Application of DSM–BIA in dry weight assessment in continuous ambulatory peritoneal dialysis Chen, Qi Wang, Zheng Liu, Na Mu, Shujuan Guo, Peng Li, Shichao Zhou, Jingwei Li, Yan Int Urol Nephrol Nephrology - Original Paper OBJECTIVES: Dry weight assessment (DWA) is an important part of dialysis and fluid management in patients receiving renal replacement therapy. With the development of bioimpedance analysis (BIA), the development of the direct segmental multi-frequency BIA (DSM–BIA) has provided a more convenient measure for DWA of dialysis patients, but its accuracy remains unclear. This study was designed to evaluate the application of DSM–BIA in DWA of continuous ambulatory peritoneal dialysis (CAPD) patients. DESIGN: This is a cross-sectional study. Using the conventional BIA as a reference, we examined the accuracy of the DSM–BIA technique for assessing dry weight in CAPD patients and analyzed the potential factors influencing their fluid volume status. SETTING AND PARTICIPANTS: A total of 31 patients with end-stage renal disease receiving CAPD and 310 healthy volunteers were recruited for this study. METHODS: The intraclass correlation coefficients (ICC) and Bland–Altman plots were used to assess the consistency between DSM–BIA and the conventional BIA for DWA. Univariate and multivariate linear regression analyses were used to explore the influencing factors associated with the edema index. RESULTS: DSM–BIA and the conventional BIA technology were consistent in DWA in CAPD patients (ICC female 0.972, ICC male 0.882, ICC total 0.960). Similarly, Bland–Altman plots showed good agreements between the two methods in DWA for both genders. Univariate and multivariate linear regression analysis showed both eGFR level (P = 0.04) and serum NT-pro BNP concentration (P = 0.007) were positively correlated with the ratio of extracellular water to total body water (ECW/TCW). CONCLUSIONS: DSM–BIA in DWA has good accuracy in clinical applications and has potential application value for fluid volume management in CAPD patients. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s11255-022-03281-7. Springer Netherlands 2022-07-04 2022 /pmc/articles/PMC9605927/ /pubmed/35789973 http://dx.doi.org/10.1007/s11255-022-03281-7 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Nephrology - Original Paper
Chen, Qi
Wang, Zheng
Liu, Na
Mu, Shujuan
Guo, Peng
Li, Shichao
Zhou, Jingwei
Li, Yan
Application of DSM–BIA in dry weight assessment in continuous ambulatory peritoneal dialysis
title Application of DSM–BIA in dry weight assessment in continuous ambulatory peritoneal dialysis
title_full Application of DSM–BIA in dry weight assessment in continuous ambulatory peritoneal dialysis
title_fullStr Application of DSM–BIA in dry weight assessment in continuous ambulatory peritoneal dialysis
title_full_unstemmed Application of DSM–BIA in dry weight assessment in continuous ambulatory peritoneal dialysis
title_short Application of DSM–BIA in dry weight assessment in continuous ambulatory peritoneal dialysis
title_sort application of dsm–bia in dry weight assessment in continuous ambulatory peritoneal dialysis
topic Nephrology - Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9605927/
https://www.ncbi.nlm.nih.gov/pubmed/35789973
http://dx.doi.org/10.1007/s11255-022-03281-7
work_keys_str_mv AT chenqi applicationofdsmbiaindryweightassessmentincontinuousambulatoryperitonealdialysis
AT wangzheng applicationofdsmbiaindryweightassessmentincontinuousambulatoryperitonealdialysis
AT liuna applicationofdsmbiaindryweightassessmentincontinuousambulatoryperitonealdialysis
AT mushujuan applicationofdsmbiaindryweightassessmentincontinuousambulatoryperitonealdialysis
AT guopeng applicationofdsmbiaindryweightassessmentincontinuousambulatoryperitonealdialysis
AT lishichao applicationofdsmbiaindryweightassessmentincontinuousambulatoryperitonealdialysis
AT zhoujingwei applicationofdsmbiaindryweightassessmentincontinuousambulatoryperitonealdialysis
AT liyan applicationofdsmbiaindryweightassessmentincontinuousambulatoryperitonealdialysis