Cargando…

Comprehensive Indicators for Evaluating and Seeking Elasto-Magnetic Parameters for High-Performance Cable Force Monitoring

The elasto-magnetic method is a promising pathway for cable force monitoring in cable-stayed bridges. Under the action of an externally applied pulsed magnetic field, both the variation in the main flux recorded by the induction coil and the localized surface magnetic field measured by the packaged...

Descripción completa

Detalles Bibliográficos
Autores principales: Yan, Shuangsheng, Wang, Yujue, Li, Peng, Gao, Zhichao, Wu, Bin, Liu, Xiucheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9607608/
https://www.ncbi.nlm.nih.gov/pubmed/36298126
http://dx.doi.org/10.3390/s22207776
_version_ 1784818588555673600
author Yan, Shuangsheng
Wang, Yujue
Li, Peng
Gao, Zhichao
Wu, Bin
Liu, Xiucheng
author_facet Yan, Shuangsheng
Wang, Yujue
Li, Peng
Gao, Zhichao
Wu, Bin
Liu, Xiucheng
author_sort Yan, Shuangsheng
collection PubMed
description The elasto-magnetic method is a promising pathway for cable force monitoring in cable-stayed bridges. Under the action of an externally applied pulsed magnetic field, both the variation in the main flux recorded by the induction coil and the localized surface magnetic field measured by the packaged magnetic sensor are typical signals for observing the elasto-magnetic effect in tensioned cables. However, the performances of the parameters extracted from the two types of elasto-magnetic signals are never strictly compared in the experiment. Meanwhile, comprehensive indicators for evaluating the ability of elasto-magnetic parameters on cable force characterization are seldom discussed. As a result, it is difficult to compare the performances of elasto-magnetic devices developed by different teams, and the pathway of seeking new parameters for cable force monitoring is obstructed. In this study, elasto-magnetic calibration experiments were performed on a cable of seven-wire steel strands to simultaneously measure the variation in the main flux and the localized surface magnetic field. Comprehensive indicators considering sensitivity, hysteresis error, and cable force resolution are proposed to examine the performances of classic elasto-magnetic parameters and new candidate ones. Through comparative study, two new parameters demonstrated outstanding ability for cable force measurement, and they are the minimum amplitude of the induced voltage and the area under the curve between two points of 3 dB height of the voltage measured by a Hall sensor. The latter is recommended for high-performance cable force monitoring from the perspective of simplicity in sensor configuration.
format Online
Article
Text
id pubmed-9607608
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96076082022-10-28 Comprehensive Indicators for Evaluating and Seeking Elasto-Magnetic Parameters for High-Performance Cable Force Monitoring Yan, Shuangsheng Wang, Yujue Li, Peng Gao, Zhichao Wu, Bin Liu, Xiucheng Sensors (Basel) Article The elasto-magnetic method is a promising pathway for cable force monitoring in cable-stayed bridges. Under the action of an externally applied pulsed magnetic field, both the variation in the main flux recorded by the induction coil and the localized surface magnetic field measured by the packaged magnetic sensor are typical signals for observing the elasto-magnetic effect in tensioned cables. However, the performances of the parameters extracted from the two types of elasto-magnetic signals are never strictly compared in the experiment. Meanwhile, comprehensive indicators for evaluating the ability of elasto-magnetic parameters on cable force characterization are seldom discussed. As a result, it is difficult to compare the performances of elasto-magnetic devices developed by different teams, and the pathway of seeking new parameters for cable force monitoring is obstructed. In this study, elasto-magnetic calibration experiments were performed on a cable of seven-wire steel strands to simultaneously measure the variation in the main flux and the localized surface magnetic field. Comprehensive indicators considering sensitivity, hysteresis error, and cable force resolution are proposed to examine the performances of classic elasto-magnetic parameters and new candidate ones. Through comparative study, two new parameters demonstrated outstanding ability for cable force measurement, and they are the minimum amplitude of the induced voltage and the area under the curve between two points of 3 dB height of the voltage measured by a Hall sensor. The latter is recommended for high-performance cable force monitoring from the perspective of simplicity in sensor configuration. MDPI 2022-10-13 /pmc/articles/PMC9607608/ /pubmed/36298126 http://dx.doi.org/10.3390/s22207776 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yan, Shuangsheng
Wang, Yujue
Li, Peng
Gao, Zhichao
Wu, Bin
Liu, Xiucheng
Comprehensive Indicators for Evaluating and Seeking Elasto-Magnetic Parameters for High-Performance Cable Force Monitoring
title Comprehensive Indicators for Evaluating and Seeking Elasto-Magnetic Parameters for High-Performance Cable Force Monitoring
title_full Comprehensive Indicators for Evaluating and Seeking Elasto-Magnetic Parameters for High-Performance Cable Force Monitoring
title_fullStr Comprehensive Indicators for Evaluating and Seeking Elasto-Magnetic Parameters for High-Performance Cable Force Monitoring
title_full_unstemmed Comprehensive Indicators for Evaluating and Seeking Elasto-Magnetic Parameters for High-Performance Cable Force Monitoring
title_short Comprehensive Indicators for Evaluating and Seeking Elasto-Magnetic Parameters for High-Performance Cable Force Monitoring
title_sort comprehensive indicators for evaluating and seeking elasto-magnetic parameters for high-performance cable force monitoring
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9607608/
https://www.ncbi.nlm.nih.gov/pubmed/36298126
http://dx.doi.org/10.3390/s22207776
work_keys_str_mv AT yanshuangsheng comprehensiveindicatorsforevaluatingandseekingelastomagneticparametersforhighperformancecableforcemonitoring
AT wangyujue comprehensiveindicatorsforevaluatingandseekingelastomagneticparametersforhighperformancecableforcemonitoring
AT lipeng comprehensiveindicatorsforevaluatingandseekingelastomagneticparametersforhighperformancecableforcemonitoring
AT gaozhichao comprehensiveindicatorsforevaluatingandseekingelastomagneticparametersforhighperformancecableforcemonitoring
AT wubin comprehensiveindicatorsforevaluatingandseekingelastomagneticparametersforhighperformancecableforcemonitoring
AT liuxiucheng comprehensiveindicatorsforevaluatingandseekingelastomagneticparametersforhighperformancecableforcemonitoring