Cargando…

Measurement of Cable Force through a Fiber Bragg Grating-Type Thin Rod Vibration Sensor and Its Application

The key to evaluating the health status of cable-stayed bridges lies in the accuracy of cable force measurement. When measuring the cable force using the conventional frequency method, the clearance between the bracing cable and the protective tube is typically disregarded. Moreover, due to their la...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, Wanxu, Teng, Wei, Liu, Fengrong, Wu, Dongwen, Wu, Yujiao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9608203/
https://www.ncbi.nlm.nih.gov/pubmed/36298433
http://dx.doi.org/10.3390/s22208081
_version_ 1784818723098460160
author Zhu, Wanxu
Teng, Wei
Liu, Fengrong
Wu, Dongwen
Wu, Yujiao
author_facet Zhu, Wanxu
Teng, Wei
Liu, Fengrong
Wu, Dongwen
Wu, Yujiao
author_sort Zhu, Wanxu
collection PubMed
description The key to evaluating the health status of cable-stayed bridges lies in the accuracy of cable force measurement. When measuring the cable force using the conventional frequency method, the clearance between the bracing cable and the protective tube is typically disregarded. Moreover, due to their large size, existing vibration sensors are difficult to install into protective tubes for steel strand-type bracing cables to measure the cable force. To address the above difficulties, a type of thin rod vibration sensor only 5 mm in diameter was designed based on the high sensitivity of Fiber Bragg grating (FBG), and high-throughput data processing software for engineering calculation (EC) was self-developed. Then, the recognition principle of the thin rod vibration sensor was theoretically analyzed and a step-by-step tension test was carried out. The results demonstrated that the relative error of the cable force measured by the thin rod vibration sensor within 12.865 Hz was less than 5% and the sensitivity reached 28.7 pm/Hz, indicating its high measurement precision. Upon subsequent application of the thin rod vibration sensor to a monitoring test in the field, the relative error of the fundamental frequency between artificial and natural excitations was less than 4%. In addition, the error relative to both the theoretical frequency and the third-party sampling frequency was less than 5%, further verifying the accuracy and applicability for monitoring the cable force of bridges under natural excitation. Compared with the traditional cantilever FBG sensor, the improved sensor with supporting data processing software has the advantages of small cross-section, high reliability, and good sensitivity. The research results can provide a reference for the subsequent accurate measurement of cable force and the development of a supporting sensor data processing system.
format Online
Article
Text
id pubmed-9608203
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96082032022-10-28 Measurement of Cable Force through a Fiber Bragg Grating-Type Thin Rod Vibration Sensor and Its Application Zhu, Wanxu Teng, Wei Liu, Fengrong Wu, Dongwen Wu, Yujiao Sensors (Basel) Article The key to evaluating the health status of cable-stayed bridges lies in the accuracy of cable force measurement. When measuring the cable force using the conventional frequency method, the clearance between the bracing cable and the protective tube is typically disregarded. Moreover, due to their large size, existing vibration sensors are difficult to install into protective tubes for steel strand-type bracing cables to measure the cable force. To address the above difficulties, a type of thin rod vibration sensor only 5 mm in diameter was designed based on the high sensitivity of Fiber Bragg grating (FBG), and high-throughput data processing software for engineering calculation (EC) was self-developed. Then, the recognition principle of the thin rod vibration sensor was theoretically analyzed and a step-by-step tension test was carried out. The results demonstrated that the relative error of the cable force measured by the thin rod vibration sensor within 12.865 Hz was less than 5% and the sensitivity reached 28.7 pm/Hz, indicating its high measurement precision. Upon subsequent application of the thin rod vibration sensor to a monitoring test in the field, the relative error of the fundamental frequency between artificial and natural excitations was less than 4%. In addition, the error relative to both the theoretical frequency and the third-party sampling frequency was less than 5%, further verifying the accuracy and applicability for monitoring the cable force of bridges under natural excitation. Compared with the traditional cantilever FBG sensor, the improved sensor with supporting data processing software has the advantages of small cross-section, high reliability, and good sensitivity. The research results can provide a reference for the subsequent accurate measurement of cable force and the development of a supporting sensor data processing system. MDPI 2022-10-21 /pmc/articles/PMC9608203/ /pubmed/36298433 http://dx.doi.org/10.3390/s22208081 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhu, Wanxu
Teng, Wei
Liu, Fengrong
Wu, Dongwen
Wu, Yujiao
Measurement of Cable Force through a Fiber Bragg Grating-Type Thin Rod Vibration Sensor and Its Application
title Measurement of Cable Force through a Fiber Bragg Grating-Type Thin Rod Vibration Sensor and Its Application
title_full Measurement of Cable Force through a Fiber Bragg Grating-Type Thin Rod Vibration Sensor and Its Application
title_fullStr Measurement of Cable Force through a Fiber Bragg Grating-Type Thin Rod Vibration Sensor and Its Application
title_full_unstemmed Measurement of Cable Force through a Fiber Bragg Grating-Type Thin Rod Vibration Sensor and Its Application
title_short Measurement of Cable Force through a Fiber Bragg Grating-Type Thin Rod Vibration Sensor and Its Application
title_sort measurement of cable force through a fiber bragg grating-type thin rod vibration sensor and its application
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9608203/
https://www.ncbi.nlm.nih.gov/pubmed/36298433
http://dx.doi.org/10.3390/s22208081
work_keys_str_mv AT zhuwanxu measurementofcableforcethroughafiberbragggratingtypethinrodvibrationsensoranditsapplication
AT tengwei measurementofcableforcethroughafiberbragggratingtypethinrodvibrationsensoranditsapplication
AT liufengrong measurementofcableforcethroughafiberbragggratingtypethinrodvibrationsensoranditsapplication
AT wudongwen measurementofcableforcethroughafiberbragggratingtypethinrodvibrationsensoranditsapplication
AT wuyujiao measurementofcableforcethroughafiberbragggratingtypethinrodvibrationsensoranditsapplication