Cargando…

Bioanalytical Method Development, Validation and Stability Assessment of Xanthohumol in Rat Plasma

Xanthohumol (XH) a prenylated chalcone has diverse therapeutic effects against various diseases. In the present study, a bioanalytical method was developed for XH in rat plasma using reverse phase high performance liquid chromatography. The validation of the method was performed as per ICH M10 guide...

Descripción completa

Detalles Bibliográficos
Autores principales: Harish, Vancha, Almalki, Waleed Hassan, Alshehri, Ahmed, Alzahrani, Abdulaziz, Alzarea, Sami I., Kazmi, Imran, Gulati, Monica, Tewari, Devesh, Chellappan, Dinesh Kumar, Gupta, Gaurav, Dua, Kamal, Singh, Sachin Kumar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9608944/
https://www.ncbi.nlm.nih.gov/pubmed/36296708
http://dx.doi.org/10.3390/molecules27207117
Descripción
Sumario:Xanthohumol (XH) a prenylated chalcone has diverse therapeutic effects against various diseases. In the present study, a bioanalytical method was developed for XH in rat plasma using reverse phase high performance liquid chromatography. The validation of the method was performed as per ICH M10 guidelines using curcumin as an internal standard. The Isocratic elution method was used with a run time of 10 min, wherein the mobile phase ratio 0.1% v/v OPA (A): Methanol (B) was 15:85 v/v at flow rate 0.8 mL/min and injection volume of 20 µL. The chromatograms of XH and curcumin was recorded at a wavelength of 370 nm. The retention time for XH and curcumin was 7.4 and 5.8 min, respectively. The spiked XH from plasma was extracted by the protein precipitation method. The developed method was linear with R(2) value of 0.9996 over a concentration range of 50–250 ng/mL along with LLOQ. The results of all the validation parameters are found to be within the accepted limits with %RSD value less than 2 and the percentage recovery was found to be greater than 95%. Based on the %RSD and percentage recovery results it was confirmed that the method was precise and accurate among the study replicates. LOD and LOQ values in plasma samples were found to be 8.49 ng/mL and 25.73 ng/mL, respectively. The stability studies like freeze thaw, short term and long-term stability studies were also performed, %RSD and percentage recovery of the XH from plasma samples were within the acceptable limits. Therefore, the developed bioanalytical method can be used effectively for estimation of XH in plasma samples.