Cargando…

Performance Analysis of a Solar Heating Ammonia Decomposition Membrane Reactor under Co-Current Sweep

Ammonia is an excellent medium for solar thermal chemical energy storage and can also use excess heat to produce hydrogen without carbon emission. To deepen the study of ammonia decomposition in these two fields, finite-time thermodynamics is used to model a solar-heating, co-current sweeping ammoni...

Descripción completa

Detalles Bibliográficos
Autores principales: Xie, Tianchao, Xia, Shaojun, Huang, Jialuo, Wang, Chao, Jin, Qinglong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9609753/
https://www.ncbi.nlm.nih.gov/pubmed/36295731
http://dx.doi.org/10.3390/membranes12100972
_version_ 1784819099782610944
author Xie, Tianchao
Xia, Shaojun
Huang, Jialuo
Wang, Chao
Jin, Qinglong
author_facet Xie, Tianchao
Xia, Shaojun
Huang, Jialuo
Wang, Chao
Jin, Qinglong
author_sort Xie, Tianchao
collection PubMed
description Ammonia is an excellent medium for solar thermal chemical energy storage and can also use excess heat to produce hydrogen without carbon emission. To deepen the study of ammonia decomposition in these two fields, finite-time thermodynamics is used to model a solar-heating, co-current sweeping ammonia decomposition membrane reactor. According to the needs of energy storage systems and solar hydrogen production, five performance indicators are put forward, including the heat absorption rate (HAR), ammonia conversion rate (ACR), hydrogen production rate (HPR), entropy generation rate (EGR) and energy conversion rate (ECR). The effects of the light intensity, ammonia flow rate, nitrogen flow rate and palladium membrane radius on system performances are further analyzed. The results show that the influences of the palladium membrane radius and nitrogen flow rate on reactor performances are very slight. When the light intensity is increased from 500 W/m(2) to 800 W/m(2), the ACR, EGR, HAR and HPR increase obviously, but the ECR decreases by 14.2%. When the ammonia flow rate is increased by 100%, the ECR, EGR and HPR increase by more than 70%, the HAR increases by 15.6% and the ACR decreases by 12.9%. At the same time, the ammonia flow rate needs to be adjusted with the light intensity. The results can provide some guiding significance for the engineering application of ammonia solar energy storage systems and solar hydrogen production.
format Online
Article
Text
id pubmed-9609753
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96097532022-10-28 Performance Analysis of a Solar Heating Ammonia Decomposition Membrane Reactor under Co-Current Sweep Xie, Tianchao Xia, Shaojun Huang, Jialuo Wang, Chao Jin, Qinglong Membranes (Basel) Article Ammonia is an excellent medium for solar thermal chemical energy storage and can also use excess heat to produce hydrogen without carbon emission. To deepen the study of ammonia decomposition in these two fields, finite-time thermodynamics is used to model a solar-heating, co-current sweeping ammonia decomposition membrane reactor. According to the needs of energy storage systems and solar hydrogen production, five performance indicators are put forward, including the heat absorption rate (HAR), ammonia conversion rate (ACR), hydrogen production rate (HPR), entropy generation rate (EGR) and energy conversion rate (ECR). The effects of the light intensity, ammonia flow rate, nitrogen flow rate and palladium membrane radius on system performances are further analyzed. The results show that the influences of the palladium membrane radius and nitrogen flow rate on reactor performances are very slight. When the light intensity is increased from 500 W/m(2) to 800 W/m(2), the ACR, EGR, HAR and HPR increase obviously, but the ECR decreases by 14.2%. When the ammonia flow rate is increased by 100%, the ECR, EGR and HPR increase by more than 70%, the HAR increases by 15.6% and the ACR decreases by 12.9%. At the same time, the ammonia flow rate needs to be adjusted with the light intensity. The results can provide some guiding significance for the engineering application of ammonia solar energy storage systems and solar hydrogen production. MDPI 2022-10-03 /pmc/articles/PMC9609753/ /pubmed/36295731 http://dx.doi.org/10.3390/membranes12100972 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Xie, Tianchao
Xia, Shaojun
Huang, Jialuo
Wang, Chao
Jin, Qinglong
Performance Analysis of a Solar Heating Ammonia Decomposition Membrane Reactor under Co-Current Sweep
title Performance Analysis of a Solar Heating Ammonia Decomposition Membrane Reactor under Co-Current Sweep
title_full Performance Analysis of a Solar Heating Ammonia Decomposition Membrane Reactor under Co-Current Sweep
title_fullStr Performance Analysis of a Solar Heating Ammonia Decomposition Membrane Reactor under Co-Current Sweep
title_full_unstemmed Performance Analysis of a Solar Heating Ammonia Decomposition Membrane Reactor under Co-Current Sweep
title_short Performance Analysis of a Solar Heating Ammonia Decomposition Membrane Reactor under Co-Current Sweep
title_sort performance analysis of a solar heating ammonia decomposition membrane reactor under co-current sweep
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9609753/
https://www.ncbi.nlm.nih.gov/pubmed/36295731
http://dx.doi.org/10.3390/membranes12100972
work_keys_str_mv AT xietianchao performanceanalysisofasolarheatingammoniadecompositionmembranereactorundercocurrentsweep
AT xiashaojun performanceanalysisofasolarheatingammoniadecompositionmembranereactorundercocurrentsweep
AT huangjialuo performanceanalysisofasolarheatingammoniadecompositionmembranereactorundercocurrentsweep
AT wangchao performanceanalysisofasolarheatingammoniadecompositionmembranereactorundercocurrentsweep
AT jinqinglong performanceanalysisofasolarheatingammoniadecompositionmembranereactorundercocurrentsweep