Cargando…
The collagen matrix dural substitute graft prevents postoperative cerebrospinal fluid leakage after ventriculoperitoneal shunt surgery in patients aged <1 year
BACKGROUND: Cerebrospinal fluid (CSF) leakage is a common complication of ventriculoperitoneal shunt (VPS) and has the potential to induce shunt infection. Especially in infants and children, these are serious complications. DuraGen is a collagen matrix dural substitute used to reduce the risk of CS...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Scientific Scholar
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9610452/ https://www.ncbi.nlm.nih.gov/pubmed/36324932 http://dx.doi.org/10.25259/SNI_629_2022 |
_version_ | 1784819272561721344 |
---|---|
author | Sato, Masanori Oyoshi, Tatsuki Iwamoto, Hirofumi Tanoue, Natsuko Komasaku, Soichiro Higa, Nayuta Hosoyama, Hiroshi Tokimura, Hiroshi Ibara, Satoshi Hanaya, Ryosuke Yoshimoto, Koji |
author_facet | Sato, Masanori Oyoshi, Tatsuki Iwamoto, Hirofumi Tanoue, Natsuko Komasaku, Soichiro Higa, Nayuta Hosoyama, Hiroshi Tokimura, Hiroshi Ibara, Satoshi Hanaya, Ryosuke Yoshimoto, Koji |
author_sort | Sato, Masanori |
collection | PubMed |
description | BACKGROUND: Cerebrospinal fluid (CSF) leakage is a common complication of ventriculoperitoneal shunt (VPS) and has the potential to induce shunt infection. Especially in infants and children, these are serious complications. DuraGen is a collagen matrix dural substitute used to reduce the risk of CSF leakage in various neurosurgeries. We report our VPS procedure with DuraGen for preventing postoperative CSF leakage in patients aged <1 year. METHODS: We used DuraGen to prevent postoperative CSF leakage in six VPS surgeries. Antibiotic-impregnated shunt catheters and programmable valves with anti-siphon devices were also used in all cases. DuraGen was placed inside and atop the burr hole. All cases had an initial shunt pressure of 5 cmH2O. Fibrin glue was not used. RESULTS: The patients underwent follow-up for a year after VPS surgery. There was no postoperative subcutaneous CSF collection or leakage after all six VPS surgeries. Furthermore, no postoperative shunt infections or DuraGen-induced adverse events were noted. CONCLUSION: We speculate that DuraGen has a preventive effect on postoperative CSF leakage in VPS cases aged <1 year. |
format | Online Article Text |
id | pubmed-9610452 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Scientific Scholar |
record_format | MEDLINE/PubMed |
spelling | pubmed-96104522022-11-01 The collagen matrix dural substitute graft prevents postoperative cerebrospinal fluid leakage after ventriculoperitoneal shunt surgery in patients aged <1 year Sato, Masanori Oyoshi, Tatsuki Iwamoto, Hirofumi Tanoue, Natsuko Komasaku, Soichiro Higa, Nayuta Hosoyama, Hiroshi Tokimura, Hiroshi Ibara, Satoshi Hanaya, Ryosuke Yoshimoto, Koji Surg Neurol Int Technical Notes BACKGROUND: Cerebrospinal fluid (CSF) leakage is a common complication of ventriculoperitoneal shunt (VPS) and has the potential to induce shunt infection. Especially in infants and children, these are serious complications. DuraGen is a collagen matrix dural substitute used to reduce the risk of CSF leakage in various neurosurgeries. We report our VPS procedure with DuraGen for preventing postoperative CSF leakage in patients aged <1 year. METHODS: We used DuraGen to prevent postoperative CSF leakage in six VPS surgeries. Antibiotic-impregnated shunt catheters and programmable valves with anti-siphon devices were also used in all cases. DuraGen was placed inside and atop the burr hole. All cases had an initial shunt pressure of 5 cmH2O. Fibrin glue was not used. RESULTS: The patients underwent follow-up for a year after VPS surgery. There was no postoperative subcutaneous CSF collection or leakage after all six VPS surgeries. Furthermore, no postoperative shunt infections or DuraGen-induced adverse events were noted. CONCLUSION: We speculate that DuraGen has a preventive effect on postoperative CSF leakage in VPS cases aged <1 year. Scientific Scholar 2022-10-07 /pmc/articles/PMC9610452/ /pubmed/36324932 http://dx.doi.org/10.25259/SNI_629_2022 Text en Copyright: © 2022 Surgical Neurology International https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-Share Alike 4.0 License, which allows others to remix, transform, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Technical Notes Sato, Masanori Oyoshi, Tatsuki Iwamoto, Hirofumi Tanoue, Natsuko Komasaku, Soichiro Higa, Nayuta Hosoyama, Hiroshi Tokimura, Hiroshi Ibara, Satoshi Hanaya, Ryosuke Yoshimoto, Koji The collagen matrix dural substitute graft prevents postoperative cerebrospinal fluid leakage after ventriculoperitoneal shunt surgery in patients aged <1 year |
title | The collagen matrix dural substitute graft prevents postoperative cerebrospinal fluid leakage after ventriculoperitoneal shunt surgery in patients aged <1 year |
title_full | The collagen matrix dural substitute graft prevents postoperative cerebrospinal fluid leakage after ventriculoperitoneal shunt surgery in patients aged <1 year |
title_fullStr | The collagen matrix dural substitute graft prevents postoperative cerebrospinal fluid leakage after ventriculoperitoneal shunt surgery in patients aged <1 year |
title_full_unstemmed | The collagen matrix dural substitute graft prevents postoperative cerebrospinal fluid leakage after ventriculoperitoneal shunt surgery in patients aged <1 year |
title_short | The collagen matrix dural substitute graft prevents postoperative cerebrospinal fluid leakage after ventriculoperitoneal shunt surgery in patients aged <1 year |
title_sort | collagen matrix dural substitute graft prevents postoperative cerebrospinal fluid leakage after ventriculoperitoneal shunt surgery in patients aged <1 year |
topic | Technical Notes |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9610452/ https://www.ncbi.nlm.nih.gov/pubmed/36324932 http://dx.doi.org/10.25259/SNI_629_2022 |
work_keys_str_mv | AT satomasanori thecollagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT oyoshitatsuki thecollagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT iwamotohirofumi thecollagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT tanouenatsuko thecollagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT komasakusoichiro thecollagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT higanayuta thecollagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT hosoyamahiroshi thecollagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT tokimurahiroshi thecollagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT ibarasatoshi thecollagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT hanayaryosuke thecollagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT yoshimotokoji thecollagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT satomasanori collagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT oyoshitatsuki collagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT iwamotohirofumi collagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT tanouenatsuko collagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT komasakusoichiro collagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT higanayuta collagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT hosoyamahiroshi collagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT tokimurahiroshi collagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT ibarasatoshi collagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT hanayaryosuke collagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year AT yoshimotokoji collagenmatrixduralsubstitutegraftpreventspostoperativecerebrospinalfluidleakageafterventriculoperitonealshuntsurgeryinpatientsaged1year |