Cargando…

Comparative Study and Simulation of Capacitive Sensors in Microfluidic Channels for Sensitive Red Blood Cell Detection

Microfluidics provides an indispensable platform for combining analytical operations such as sample preparation, mixing, separation/enrichment, and detection onto a single compact platform, defined as a lab-on-a-chip (LOC) device with applicability in biomedical and life science applications. Due to...

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Wei, Wu, Bingxing, Srivastava, Soumya K., Ay, Suat Utku
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9610494/
https://www.ncbi.nlm.nih.gov/pubmed/36296007
http://dx.doi.org/10.3390/mi13101654
_version_ 1784819283391414272
author Hu, Wei
Wu, Bingxing
Srivastava, Soumya K.
Ay, Suat Utku
author_facet Hu, Wei
Wu, Bingxing
Srivastava, Soumya K.
Ay, Suat Utku
author_sort Hu, Wei
collection PubMed
description Microfluidics provides an indispensable platform for combining analytical operations such as sample preparation, mixing, separation/enrichment, and detection onto a single compact platform, defined as a lab-on-a-chip (LOC) device with applicability in biomedical and life science applications. Due to its ease of integration, 1D interdigital capacitive (IDC) sensors have been used in microfluidic platforms to detect particles of interest. This paper presents a comparative study on the use of capacitive sensors for microfluidic devices to detect bioparticles, more specifically red blood cells (RBCs). The detection sensitivities of 1D, 2D, and 3D capacitive sensors were determined by simulation using COMSOL Multiphysics(®) v5.5. A water-filled 25 μm × 25 μm PDMS microfluidic channel was used with different sizes (5–10 μm) of red blood cells passing across the capacitive sensor regions. The conformal mapping was used for translating the 1D IDC sensor dimensions into equivalent 2D/3D parallel plate capacitance (PPC) sensor dimensions, creating similar absolute sensor capacitance. The detection sensitivity of each capacitive sensor is determined, and a new 3D PPC sensor structure was proposed to improve the sensitivity for high-resolution RBC detection in microfluidic channels. Proposed 2D and 3D sensors provide a 3× to 20× improvement in sensitivity compared to the standard 1D IDC structures, achieving a 100 aF capacitance difference when a healthy RBC passes in the structure.
format Online
Article
Text
id pubmed-9610494
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96104942022-10-28 Comparative Study and Simulation of Capacitive Sensors in Microfluidic Channels for Sensitive Red Blood Cell Detection Hu, Wei Wu, Bingxing Srivastava, Soumya K. Ay, Suat Utku Micromachines (Basel) Article Microfluidics provides an indispensable platform for combining analytical operations such as sample preparation, mixing, separation/enrichment, and detection onto a single compact platform, defined as a lab-on-a-chip (LOC) device with applicability in biomedical and life science applications. Due to its ease of integration, 1D interdigital capacitive (IDC) sensors have been used in microfluidic platforms to detect particles of interest. This paper presents a comparative study on the use of capacitive sensors for microfluidic devices to detect bioparticles, more specifically red blood cells (RBCs). The detection sensitivities of 1D, 2D, and 3D capacitive sensors were determined by simulation using COMSOL Multiphysics(®) v5.5. A water-filled 25 μm × 25 μm PDMS microfluidic channel was used with different sizes (5–10 μm) of red blood cells passing across the capacitive sensor regions. The conformal mapping was used for translating the 1D IDC sensor dimensions into equivalent 2D/3D parallel plate capacitance (PPC) sensor dimensions, creating similar absolute sensor capacitance. The detection sensitivity of each capacitive sensor is determined, and a new 3D PPC sensor structure was proposed to improve the sensitivity for high-resolution RBC detection in microfluidic channels. Proposed 2D and 3D sensors provide a 3× to 20× improvement in sensitivity compared to the standard 1D IDC structures, achieving a 100 aF capacitance difference when a healthy RBC passes in the structure. MDPI 2022-09-30 /pmc/articles/PMC9610494/ /pubmed/36296007 http://dx.doi.org/10.3390/mi13101654 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hu, Wei
Wu, Bingxing
Srivastava, Soumya K.
Ay, Suat Utku
Comparative Study and Simulation of Capacitive Sensors in Microfluidic Channels for Sensitive Red Blood Cell Detection
title Comparative Study and Simulation of Capacitive Sensors in Microfluidic Channels for Sensitive Red Blood Cell Detection
title_full Comparative Study and Simulation of Capacitive Sensors in Microfluidic Channels for Sensitive Red Blood Cell Detection
title_fullStr Comparative Study and Simulation of Capacitive Sensors in Microfluidic Channels for Sensitive Red Blood Cell Detection
title_full_unstemmed Comparative Study and Simulation of Capacitive Sensors in Microfluidic Channels for Sensitive Red Blood Cell Detection
title_short Comparative Study and Simulation of Capacitive Sensors in Microfluidic Channels for Sensitive Red Blood Cell Detection
title_sort comparative study and simulation of capacitive sensors in microfluidic channels for sensitive red blood cell detection
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9610494/
https://www.ncbi.nlm.nih.gov/pubmed/36296007
http://dx.doi.org/10.3390/mi13101654
work_keys_str_mv AT huwei comparativestudyandsimulationofcapacitivesensorsinmicrofluidicchannelsforsensitiveredbloodcelldetection
AT wubingxing comparativestudyandsimulationofcapacitivesensorsinmicrofluidicchannelsforsensitiveredbloodcelldetection
AT srivastavasoumyak comparativestudyandsimulationofcapacitivesensorsinmicrofluidicchannelsforsensitiveredbloodcelldetection
AT aysuatutku comparativestudyandsimulationofcapacitivesensorsinmicrofluidicchannelsforsensitiveredbloodcelldetection