Cargando…

Algorithm for Designing a Removable Complete Denture (RCD) Based on the FEM Analysis of Its Service Life

(1) Background: The paper addresses the computer simulation and prediction of the service life of the base of removable complete dentures (RCDs) under typical loads caused by biting and chewing food. For this purpose, the finite element method (FEM) was used. It is assumed that various blocks of tee...

Descripción completa

Detalles Bibliográficos
Autores principales: Grachev, Dmitry I., Ruzuddinov, Nurmukhamet S., Arutyunov, Anatoliy S., Akhmedov, Gadzhi D., Dubova, Lubov V., Kharakh, Yaser N., Panin, Sergey V., Arutyunov, Sergey D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9610509/
https://www.ncbi.nlm.nih.gov/pubmed/36295314
http://dx.doi.org/10.3390/ma15207246
Descripción
Sumario:(1) Background: The paper addresses the computer simulation and prediction of the service life of the base of removable complete dentures (RCDs) under typical loads caused by biting and chewing food. For this purpose, the finite element method (FEM) was used. It is assumed that various blocks of teeth, such as incisors, canines, premolars and molars, are subjected to cyclic impacts during a human life. (2) Methods: Both symmetric and asymmetric mastication (two- and one-sided loads, respectively) cases were considered. The load level was assumed to be 100 N, which corresponds to the average muscular compression force of typical human jaws. (3) Results: The FEM analysis of the stress–strain state evolution for RCDs under cyclic loads was carried out. Maps of equivalent lines were drawn for the denture base in terms of its durability. A multi-axial criterion was implemented to determine the number of cycles prior to failure by the mechanism of a normal opening mode crack. The FEM-based assessment of the service life of RCDs enabled us to establish the critical stress concentration areas, thereby allowing for further planning for the correction of an occlusal scheme or teeth inclinations. As a result, the service life of RCDs under cyclic loading can be improved. (4) Conclusions: An algorithm for designing RCDs in the case of edentulism based on the FEM simulation using commercial software as part of the procedure is proposed.