Cargando…
A Highly Accurate Method for Measuring Response Time of MEMS Thermopiles
The response time is an important parameter for thermopiles sensors, which reflects the response speed of the device. The accurate measurement of response time is extremely important to evaluate device characteristics for using them in suitable scenarios. In this work, to accurately measure the resp...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9610767/ https://www.ncbi.nlm.nih.gov/pubmed/36296070 http://dx.doi.org/10.3390/mi13101717 |
_version_ | 1784819359177244672 |
---|---|
author | Xiang, Zeqing Shi, Meng Zhou, Na Zhang, Chenchen Ding, Xuefeng Ni, Yue Chen, Dapeng Mao, Haiyang |
author_facet | Xiang, Zeqing Shi, Meng Zhou, Na Zhang, Chenchen Ding, Xuefeng Ni, Yue Chen, Dapeng Mao, Haiyang |
author_sort | Xiang, Zeqing |
collection | PubMed |
description | The response time is an important parameter for thermopiles sensors, which reflects the response speed of the device. The accurate measurement of response time is extremely important to evaluate device characteristics for using them in suitable scenarios. In this work, to accurately measure the response time of thermopile sensors, an Al microheater is integrated in a MEMS thermopile as an in situ heat source. Compared with the traditional chopper measurement method for response time, this approach avoids mechanical delay induced by chopper blades. Accordingly, based on this approach, the response time of the device is measured to be 6.9 ms, while that is 12.7 ms when a chopping system is used, demonstrating that an error of at least 5.8 ms is avoided. Such an approach is quite simple to realize and provides a novel route to accurately measure the response time. |
format | Online Article Text |
id | pubmed-9610767 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-96107672022-10-28 A Highly Accurate Method for Measuring Response Time of MEMS Thermopiles Xiang, Zeqing Shi, Meng Zhou, Na Zhang, Chenchen Ding, Xuefeng Ni, Yue Chen, Dapeng Mao, Haiyang Micromachines (Basel) Article The response time is an important parameter for thermopiles sensors, which reflects the response speed of the device. The accurate measurement of response time is extremely important to evaluate device characteristics for using them in suitable scenarios. In this work, to accurately measure the response time of thermopile sensors, an Al microheater is integrated in a MEMS thermopile as an in situ heat source. Compared with the traditional chopper measurement method for response time, this approach avoids mechanical delay induced by chopper blades. Accordingly, based on this approach, the response time of the device is measured to be 6.9 ms, while that is 12.7 ms when a chopping system is used, demonstrating that an error of at least 5.8 ms is avoided. Such an approach is quite simple to realize and provides a novel route to accurately measure the response time. MDPI 2022-10-11 /pmc/articles/PMC9610767/ /pubmed/36296070 http://dx.doi.org/10.3390/mi13101717 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Xiang, Zeqing Shi, Meng Zhou, Na Zhang, Chenchen Ding, Xuefeng Ni, Yue Chen, Dapeng Mao, Haiyang A Highly Accurate Method for Measuring Response Time of MEMS Thermopiles |
title | A Highly Accurate Method for Measuring Response Time of MEMS Thermopiles |
title_full | A Highly Accurate Method for Measuring Response Time of MEMS Thermopiles |
title_fullStr | A Highly Accurate Method for Measuring Response Time of MEMS Thermopiles |
title_full_unstemmed | A Highly Accurate Method for Measuring Response Time of MEMS Thermopiles |
title_short | A Highly Accurate Method for Measuring Response Time of MEMS Thermopiles |
title_sort | highly accurate method for measuring response time of mems thermopiles |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9610767/ https://www.ncbi.nlm.nih.gov/pubmed/36296070 http://dx.doi.org/10.3390/mi13101717 |
work_keys_str_mv | AT xiangzeqing ahighlyaccuratemethodformeasuringresponsetimeofmemsthermopiles AT shimeng ahighlyaccuratemethodformeasuringresponsetimeofmemsthermopiles AT zhouna ahighlyaccuratemethodformeasuringresponsetimeofmemsthermopiles AT zhangchenchen ahighlyaccuratemethodformeasuringresponsetimeofmemsthermopiles AT dingxuefeng ahighlyaccuratemethodformeasuringresponsetimeofmemsthermopiles AT niyue ahighlyaccuratemethodformeasuringresponsetimeofmemsthermopiles AT chendapeng ahighlyaccuratemethodformeasuringresponsetimeofmemsthermopiles AT maohaiyang ahighlyaccuratemethodformeasuringresponsetimeofmemsthermopiles AT xiangzeqing highlyaccuratemethodformeasuringresponsetimeofmemsthermopiles AT shimeng highlyaccuratemethodformeasuringresponsetimeofmemsthermopiles AT zhouna highlyaccuratemethodformeasuringresponsetimeofmemsthermopiles AT zhangchenchen highlyaccuratemethodformeasuringresponsetimeofmemsthermopiles AT dingxuefeng highlyaccuratemethodformeasuringresponsetimeofmemsthermopiles AT niyue highlyaccuratemethodformeasuringresponsetimeofmemsthermopiles AT chendapeng highlyaccuratemethodformeasuringresponsetimeofmemsthermopiles AT maohaiyang highlyaccuratemethodformeasuringresponsetimeofmemsthermopiles |