Cargando…

Optimization of Electrode Patterns for an ITO-Based Digital Microfluidic through the Finite Element Simulation

Indium tin oxide (ITO)-based digital microfluidics (DMF) with unique optical and electrical properties are promising in the development of integrated, automatic and portable analytical systems. The fabrication technique using laser direct etching (LDE) on ITO glass has the advantages of being rapid,...

Descripción completa

Detalles Bibliográficos
Autores principales: Song, Ze-Rui, Zeng, Jin, Zhou, Jia-Le, Yan, Bing-Yong, Gu, Zhen, Wang, Hui-Feng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9611684/
https://www.ncbi.nlm.nih.gov/pubmed/36295916
http://dx.doi.org/10.3390/mi13101563
_version_ 1784819589657395200
author Song, Ze-Rui
Zeng, Jin
Zhou, Jia-Le
Yan, Bing-Yong
Gu, Zhen
Wang, Hui-Feng
author_facet Song, Ze-Rui
Zeng, Jin
Zhou, Jia-Le
Yan, Bing-Yong
Gu, Zhen
Wang, Hui-Feng
author_sort Song, Ze-Rui
collection PubMed
description Indium tin oxide (ITO)-based digital microfluidics (DMF) with unique optical and electrical properties are promising in the development of integrated, automatic and portable analytical systems. The fabrication technique using laser direct etching (LDE) on ITO glass has the advantages of being rapid, low cost and convenient. However, the fabrication resolution of LDE limits the minimum line width for patterns on ITO glasses, leading to a related wider lead wire for the actuating electrodes of DMF compared with photolithography. Therefore, the lead wire of electrodes could affect the droplet motion on the digital microfluidic chip due to the increased contact line with the droplet. Herein, we developed a finite element model of a DMF with improved efficiency to investigate the effect of the lead wire. An optimized electrode pattern was then designed based on a theoretical analysis and validated by a simulation, which significantly decreased the deformation of the droplets down to 0.012 mm. The performance of the optimized electrode was also verified in an experiment. The proposed simulation method could be further extended to other DMF systems or applications to provide an efficient approach for the design and optimization of DMF chips.
format Online
Article
Text
id pubmed-9611684
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-96116842022-10-28 Optimization of Electrode Patterns for an ITO-Based Digital Microfluidic through the Finite Element Simulation Song, Ze-Rui Zeng, Jin Zhou, Jia-Le Yan, Bing-Yong Gu, Zhen Wang, Hui-Feng Micromachines (Basel) Communication Indium tin oxide (ITO)-based digital microfluidics (DMF) with unique optical and electrical properties are promising in the development of integrated, automatic and portable analytical systems. The fabrication technique using laser direct etching (LDE) on ITO glass has the advantages of being rapid, low cost and convenient. However, the fabrication resolution of LDE limits the minimum line width for patterns on ITO glasses, leading to a related wider lead wire for the actuating electrodes of DMF compared with photolithography. Therefore, the lead wire of electrodes could affect the droplet motion on the digital microfluidic chip due to the increased contact line with the droplet. Herein, we developed a finite element model of a DMF with improved efficiency to investigate the effect of the lead wire. An optimized electrode pattern was then designed based on a theoretical analysis and validated by a simulation, which significantly decreased the deformation of the droplets down to 0.012 mm. The performance of the optimized electrode was also verified in an experiment. The proposed simulation method could be further extended to other DMF systems or applications to provide an efficient approach for the design and optimization of DMF chips. MDPI 2022-09-21 /pmc/articles/PMC9611684/ /pubmed/36295916 http://dx.doi.org/10.3390/mi13101563 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Song, Ze-Rui
Zeng, Jin
Zhou, Jia-Le
Yan, Bing-Yong
Gu, Zhen
Wang, Hui-Feng
Optimization of Electrode Patterns for an ITO-Based Digital Microfluidic through the Finite Element Simulation
title Optimization of Electrode Patterns for an ITO-Based Digital Microfluidic through the Finite Element Simulation
title_full Optimization of Electrode Patterns for an ITO-Based Digital Microfluidic through the Finite Element Simulation
title_fullStr Optimization of Electrode Patterns for an ITO-Based Digital Microfluidic through the Finite Element Simulation
title_full_unstemmed Optimization of Electrode Patterns for an ITO-Based Digital Microfluidic through the Finite Element Simulation
title_short Optimization of Electrode Patterns for an ITO-Based Digital Microfluidic through the Finite Element Simulation
title_sort optimization of electrode patterns for an ito-based digital microfluidic through the finite element simulation
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9611684/
https://www.ncbi.nlm.nih.gov/pubmed/36295916
http://dx.doi.org/10.3390/mi13101563
work_keys_str_mv AT songzerui optimizationofelectrodepatternsforanitobaseddigitalmicrofluidicthroughthefiniteelementsimulation
AT zengjin optimizationofelectrodepatternsforanitobaseddigitalmicrofluidicthroughthefiniteelementsimulation
AT zhoujiale optimizationofelectrodepatternsforanitobaseddigitalmicrofluidicthroughthefiniteelementsimulation
AT yanbingyong optimizationofelectrodepatternsforanitobaseddigitalmicrofluidicthroughthefiniteelementsimulation
AT guzhen optimizationofelectrodepatternsforanitobaseddigitalmicrofluidicthroughthefiniteelementsimulation
AT wanghuifeng optimizationofelectrodepatternsforanitobaseddigitalmicrofluidicthroughthefiniteelementsimulation